- Browse Categories
- EMMPT48 series MPPT solar charge controller
- The Explorer-NS series MPPT solar charge controlle
- MPPT solar charge controller eSmart4
- EXPLORER-M MPPT Solar Smart Digital Controller
- EXPLORER MPPT Solar Smart Digital Controller
- RUNNER MPPT Solar Smart Digital Controller
- GALAXY high power series MPPT solar controller
- MARS outdoor series MPPT solar controller
- eSMART series MPPT solar controller
- MASTER series MPPT solar controller
- Accessories
- SMF Series High-Precision Intelligent MPPT Solar Charge Controller
- MCJ48 Series MPPT Solar charging controller
- Communication Base Station PV Controller Solution(CPM8/16 Combiner Box+Controller)
- (out of product)WISER series MPPT solar controller
- (out of production)Inverter SP Series 350W-20000W
- (Has been removed)
- (out of production)I-Panda SPC Series Inverter
- Certifications
-
- Subscribe
-
Get email updates on new products
- Hot Products
- Contact Us
-
Tel: + 86-755-23091101&+86-755-23091100
Fax: + 86-755-23091102
Information: info@ipandee.com
address: Floor 2, building A2, LiLang Software Park, No. 31, Bulan Road, Nanwan street, Longgang District, Shenzhen
China Post code: 518000 Contact Now
- Follow us
- News
-
-
Why is the inverter starting voltage higher than the minimum voltage?
In the photovoltaic grid-connected inverter, one parameter is strange, that is, the inverter input starting voltage. This voltage is about 30V higher ... -
How to solve the AC inverter overvoltage problem?
just nowPhotovoltaicOn-grid power generation is becoming more and more popular, and ordinary people's homes can see PV power plants in real time. Howe... -
The difference between an improved sine wave and a pure sine wave inverter
This article describes the difference between an improved sine wave and a pure sine wave inverter. ModifiedSine Pure Wave: The most common general pur... -
Europe's first waste photovoltaic panel recycling plant
Solar panels have a service life of 20 to 30 years. Along with the mass production of the global solar energy manufacturing industry in the past few y... -
The world's top ten PV inverter companies
The inverter is also called the power regulator. According to the use of the inverter in the photovoltaic power generation system, it can be divided i... -
What is the difference between MPPT function and solar inverter without MPPT function?
The MPPT controller utilizes maximum power point tracking technology to extract the maximum power from the solar array to charge the battery. The maxi... -
Why should the inverter stop working when the grid is out of power?
Some people install a photovoltaic system, they will have a mentality of "even if the power grid is cut off, if there is a sun, and their homes can us... -
Scientists have discovered that sand can make solar cell silicon materials
According to a report by the Kyodo News Agency on November 6th, visiting professors of the University of Tokyo, Sugawara, and others opened a joint st... -
How to build a photovoltaic power station
1. What kind of roof is suitable for the installation of photovoltaic power plants? The most suitable for the installation of domestic photovoltaic ro... -
Domestic energy storage market competition pattern
Energy storage as a new market for many battery manufacturers in China andInverterVendors bring the opportunity to expand new affairs and change the p...
-
IPANDEE High Power and Tenuage 96v 192v 216v 240v 384V Galaxy Series MPPT Solar Controller
- Model : Galaxy
- System voltage: DC96V/192V/216V/240V/384V Automatic recognition
- Current current: 50a;60a;70a;80th
- Maximum PV voltage (VOC): 430V/850V
High power and voltage 96v 192v 216v 240v 384v Solar controller MPPT MPPT
The Galaxy series is a maximum power point monitoring function (MPPT) with high -efficiency MPPT controller mas has many advantages such as the large photovoltaic input, it is possible to set the voltage of the charger, RS485 or RS232 (optional) eCommunication door Lan.design modular, small volume, light weight, high conversion efficiency. It is the high -end product in the solar market.
Product model
Model | Battery system | Max. Photovoltaic input intention | Nominal current |
Galaxy-B96-XXA | 96V (8*12V) | 430V | 70a;80th |
Galaxy-B192-XXA | 192v (16*12v) | 430V | 50a;60th |
Galaxy -B216 (220) -xxa | 216v (18*12v) | ||
Galaxy-B240-XXA | 240V (20*12V) | ||
Galaxy-B384-XXA | 384V (32*12V) | 850V | 70a;80th |
Characteristic
1.A has an efficient MPPT algorithm, MPPT efficiency ≥99.5%█ and efficiency of the converter up to 98%.
2. Charge mode: three phases (constant current, constant voltage, mobile charge), extends the duration of the batteries.
3. Four types of load mode selection: on/off, control of photovoltaic voltage, double -time control, PV+time control.
4. Prepreter me settings of the commonly used lead lead parameters (seal gel flood) Fance are selected by the user and the user can also customize the parameters for other battery charging.
5. It takes a current limiting top -up function. When the power of the photovoltaic is too large, the controller automatically maintains the charging power and the charging current will not exceed the nominal value.
6. Suport Multi - Machine Parallel to create the system power supply.
7. High definition LCD display function to also check the data in execution of the device and the state of work, it can also support modify the controller display parameter.
8.RS485 communication, we can offer a communication protocol to the comfortable integrated management of the user and secondary development.
9.Support PC software monitoring and wifi module to create the cloud app monitoring.
10.ce, Rohs, approved FCC certifications, we can help customers pass various certifications.
11.3 years of guarantee and 3 ~ 10 years an extensive guarantee service may also be provided.
PC software, monitoring software, view and set the parameter
PC software
View state of charge and discharge, photovoltaic voltage, charge voltage, charge current etc.And the related parameter can be set.
parameter
GALAXY | Series | B96 | B192 B216 (220) B240 | ||||||
Power model | 70th | 80th | 100a | 50th | 60th | 70th | 80th | 100a | |
Product category | Property of the controller | MPPT (maximum tracking of the power point) | |||||||
MPPT efficiency | ≥98% | ≥98% | ≥98% | ≥98% | ≥98% | ≥98% | ≥98% | ≥98% | |
System voltage | DC96V | DC192V DC216V (DC220V) DC240V | |||||||
Gamma of Videndification | DC72V ~ DC128V | DC144V ~ DC256V DC162V ~ DC288V DC180V ~ DC320V | |||||||
Method that is dissipating of heat | Cooling of the intelligent fan | ||||||||
Input features | Vmax-PV open circuit | DC430V | DC430V | DC430V | DC660V | DC660V | DC660V | ||
Start Charge Vstart-PV | Vbat+20v | Vbat+20v | Vbat+20v | Vbat+20v | Vbat+20v | Vbat+20v | Vbat+20v | Vbat+20v | |
With low protection Vlow-PV | Vbat+10v | Vbat+10v | Vbat+10v | Vbat+10v | Vbat+10v | Vbat+10v | Vbat+10v | Vbat+10v | |
Over Protection Vover-PV | DC430V | DC430V | DC430V | DC430V | DC430V | DC660V | DC660V | DC660V | |
Nominal photovoltaic power | 7280w | 8320W | 10400 | 10400W | 12480w | 14560W | 16640W | 20800W | |
11700W | 14040W | 16380w | 18720W | 23400W | |||||
13000W | 15600W | 18200w | 20800W | 26000w | |||||
Charge features | Selectable battery types | The sealed lead acid, the gel battery, flooded (also other types of batteries)- default gel battery can also be defined | |||||||
Current classified in charge | 70th | 80th | 100a | 50th | 60th | 70th | 80th | 100a | |
Charging method | 3 stadiums: constant current (quick loading) -Caric to the flourishing of the voltage | ||||||||
Loading characteristics | Load voltage | The same as the battery voltage | The same as the battery voltage | - | - | - | |||
Current current charge | 70th | 80th | 100a | 50th | 60th | - | - | - | |
Method control of loading | On off methods, mode of control of photovoltaic voltage, double -time control mode, PV + Time control mode | - | - | - | |||||
Display and communication | Display mode | LCD128*64 POINT POINTS/ RETROILLUMPATION display | |||||||
Methods of communication | 8 -pin RJ45 port | ||||||||
Other parameters | Protect the function | Input-output on in protection of voltage, prevention of the reverse protection of connection etc. | |||||||
Operating temperature | -20 ℃ ~+50 ℃ | ||||||||
Storage temperature | -40 ℃ ~+75 ℃ | ||||||||
IP (entrance protection) | IP21 | ||||||||
Net weight (kg) | 14.7 kg | 14.7 kg | 18.8 kg | ||||||
Gross weight (kg) | 16.6 kg | 16.6 kg | 20.6 kg | ||||||
Product size (mm) | 371*500*187 | 371*500*187 | 391*500*227 | ||||||
Packing size (mm) | 590*420*270 | 590*420*270 | 590*440*320 | ||||||
System connection diagram
Parallel connection diagram
Note: above is the company's standard parameters, any modification controls our official website.