- Browse Categories
- EMMPT48 series MPPT solar charge controller(1)
- The Explorer-NS series MPPT solar charge controlle(1)
- MPPT solar charge controller eSmart4(1)
- EXPLORER-M MPPT Solar Smart Digital Controller(15)
- EXPLORER MPPT Solar Smart Digital Controller(12)
- RUNNER MPPT Solar Smart Digital Controller(9)
- GALAXY high power series MPPT solar controller(12)
- MARS outdoor series MPPT solar controller(10)
- eSMART series MPPT solar controller(23)
- MASTER series MPPT solar controller(28)
- Accessories(3)
- (out of product)WISER series MPPT solar controller(12)
- (out of production)Inverter SP Series 350W-20000W(110)
- (out of production)I-Panda SPC Series Inverter(70)
- (Has been removed)(517)
- (out of product)WISER series MPPT solar controller(1)
- High frequency pure sine wave inverter (stop)(9)
- TPI2 HPC (stop)(72)
- e-SMART Solar Controller (Stop)(109)
- First Generation MPPT Controller(stop)(71)
- Second Generation MPPT Controller(stop)(119)
- TPI2 Inverter (stop)(27)
- Certifications
- Subscribe
-
Get email updates on new products
- Contact us
- Tel: + 86-755-23091101&+86-755-23091100
Fax: + 86-755-23091102
Information: info@ipandee.com
address: Floor 2, building A2, LiLang Software Park, No. 31, Bulan Road, Nanwan street, Longgang District, Shenzhen
China Post code: 518000Contact Now
- Share
Products
The pure sine wave inverter I-Panda TPI 2 series 1000w-6000w
- Introduction
- Adopting the world leading low-frequency inversion technical solutions, this series of inverters has the advantages of high conversion efficiency, low power consumption, super load-carrying ability, and large charging current.User can choose sleep mode and normal working mode according to the using environment. Also, the output priority (AC first or DC first) and the output frequency canbe set by user.It's our updated inverter based on the original TPI series.
Features
1. Pure sine wave output.
2. CPU management, intelligent control, modular design.
3. LCD and LED display. can visually display all working parameters and status(such as input voltage, output voltage, output frequency, battery capacity,load condition, status information, etc).
4. Sleep mode and normal working mode.the output priority (AC first or DC first) and the output frequency (50 HZ or 60 HZ) can be set to satisfy user with different using environment.
5. High conversion efficiency (87%-98%), low power consumption (1W~6W under sleep mode). It is the best choice of inverters for solar power system.
6. 8 kinds of batteries can be charged on global market, such as sealed lead acid battery, open lead- acid battery, gel battery, etc. Kindly note that to charge lithium battery, the related parameters need to be set in factory.
7. High charging power and the charging function can be closed
8. This series of inverters have strong load-carrying ability and overload capacity. The peak power is 3 times of the rated output power. For example, 1KW rated power inverter can carry 1HP air conditioner, and 2KW for 2HP, 3KW for 3HP, etc.
9. Adopting the latest American low frequency circuit design, brand new imported electric materials, pure copper transformer, the system is very stable, and has low malfunction rate, long service life(more than 5 years under normal use)
10. Perfect protection (low voltage protection, over voltage protection, overheats protection, short-circuit protection, overloads protection)
11. EMC, LVD, RoHS approvals
12. 2-year warranty and life-long technical support
Application
1. Back-up UPS and EPS system for military, industrial, commercial, household, etc..
2. Mobile power and standby power for areas that are lack of utility
3. Off-grid solar & wind power system
3.1. Simple Off-grid solar & wind power system
3.2. AC first Off-grid solar & wind power system
3.3. DC first Off-grid solar & wind power system
In all the above application fields, this series of inverter is suitable for all kinds of inductive loads, capacitive load and resistive load such as air conditioner, refrigerator, washing machine, TV, etc.
Function
1. Inversion function
Can be set to normal working mode (press the button to “ON”) and sleep mode (press the button to “S-ON”)

1.1 Normal working mode (ON): No matter whether there are AC loads
connected to the inverter or not, the output terminal of inverter will always have voltage ready to supply power to the loads. Under this mode, the power consumption is a little higher and the LCD will display the output voltage.
1.2 Sleep mode (S-ON): If the power of the loads that connected to the inverter is lower than 30W, there will be no output from the inverter. That is to say, only the chip of inverter is working under such condition and the power consumption is only 1-6W; If the power of the loads that connected to the inverter is more than 30W, then the inverter will automatically start the inversion function and supply power to the loads within 5s. The LCD will display no output.
2. High-power intelligent charging function
Can charge 8 kinds of conventional batteries on global market (refer to the parameter for more details)
Great charging power (refer to the parameter for more details)
Three-stage charging mode: Constant current charging stage (CC), Constant voltage charging stage (CV), Float charging stage (CF)

PS: when the battery type is set to “0”, it will not charge the battery and charging current is “0”. Also the charging indicator will not light.
3. UPS function
Can be set as utility first, battery standby mode and battery first, utility standby mode.

3.1. Utility first, battery standby UPS mode (press the button to “AC”)
When both utility and battery are connected to the inverter, utility will supply power to the loads prior to the battery. When utility is cut off, the battery will automatically continue to supply power after inversion.
Steps are as follows:
Step 1: When utility power is available, it will output directly and charge batteries at the same time (can set battery type)
Step 2: When utility power is cut off suddenly, the inverter will convert DC power (battery) to AC power automatically to ensure uninterrupted power supply within 5ms.
Step 3: When utility power becomes available again, it will automatically transfer to utility supplying power to loads and charge batteries at the same time ((can set battery type)
See Workflow as below.

3.2. Battery first, utility standby UPS mode (press the button to “DC”).
Under this mode, it will not charge the battery and the “battery type” need to set to “0”
When both utility and battery are connected to the inverter, battery will supply power to the loads prior to utility. When battery capacity is not
enough, utility will continue to supply power automatically.
Steps are as follows:
Step 1: When battery has enough power, it will supply power to the loads directly
Step 2: When battery does not have enough power, it will automatically transfer to utility supplying power to the loads
Step 3: After the battery is fully charged (e.g. by solar or wind charge controller), it will then automatically transfer to battery supplying power to the loads.
See Workflow as below.

Model Parameter |
1000W |
2000W |
3000W |
4000W
|
5000W |
6000W |
||||
Rated Output Power |
1000W |
2000W |
3000W |
4000W |
5000W |
6000W |
||||
Peak Power |
3000W |
6000W |
9000W |
12000W |
15000W |
18000W |
||||
Battery Voltage(DC) |
12V or 24V or 48V(optional) |
24V or 48V(optional) |
||||||||
Size W×D×H(mm) |
318*218*368 |
440*218*400 |
||||||||
Packing Size W×D×H(mm) |
395*275*520 |
520*275*520 |
||||||||
Net Weight (kg) |
27 |
28 |
30 |
39 |
40 |
51 |
||||
Gross Weight (kg) |
29 |
30 |
32 |
43 |
48 |
53 |
||||
Working Mode (Setting) |
ON |
Normal working mode |
||||||||
S-ON |
Sleep Mode,no utility,load's power higher than 30 W, start to work automatically |
|||||||||
OFF |
Completely off |
|||||||||
AC Input |
Voltage |
220V±35% or 110V+35%(optional) |
||||||||
Frequency |
Decided by nationality,50HZ or 60HZ |
|||||||||
AC Output |
Voltage |
220V±3% or 230V±3 or 240V±3% or 100V±3% |
||||||||
Frequency |
Under utility mode:frequency is the same as |
|||||||||
Utility
Charging |
AC
Charge Current |
BAT |
1000W |
2000W |
3000W |
4000W |
5000W |
6000W |
||
12V |
35A |
65A |
75A |
/ |
/ |
/ |
||||
24V |
20A |
35A |
45A |
65A |
70A |
75A |
||||
48V |
10A |
15A |
30A |
35A |
40A |
50A |
||||
Battery Type |
American gel battery, Wool battery 1, Wool battery2, Sealed Lead Acid Battery, Europe gel battery, Open lead-acid batteries, Calcium Battery, De-Acid Battery or OEM Battery |
|||||||||
Charging Mode |
Three-stage charging: CC, CV, CF. |
|||||||||
Charging Time |
Decided by battery capacity and quantity |
|||||||||
Battery Protection |
Automatic detection,charge and discharge protection, intelligent management |
|||||||||
UPS Priority |
AC |
Utility first, battery standby |
||||||||
DC |
Battery first, utility standby |
|||||||||
Display |
Display Mode |
LCD+LED |
||||||||
Display Information |
Input voltage,output voltage,output frequency,battery capacity,Load condition,Status Information |
|||||||||
Output Wave Type |
Pure sine wave |
|||||||||
Overload Ability |
>120% 1 min,>130% 10s |
|||||||||
Power Consumption |
Sleep Mode |
1~6W |
||||||||
Normal Mode |
1~3A |
|||||||||
Conversion Efficiency |
80%~90% |
|||||||||
Transfer Time |
<5ms (AC to DC / DC to AC) |
|||||||||
Protection |
Overload output,short-circuit,high-voltage input,low-voltage input,overheats |
|||||||||
Environment |
Temperature |
-10℃~50℃ |
||||||||
Humidity |
10%~90% |
|||||||||
Altitude |
≤4000m |
The above is our standard parameter. Subject to change without prior notice.
We have our own professional inverter and controller R&D team and we provide technical support and OEM service.
Others
Please refer to the outline design, technical documents, product brochures, etc.
Made by Engineering Department, May 13, 2014, 2nd Edition