- Browse Categories
- EMMPT48 series MPPT solar charge controller
- The Explorer-NS series MPPT solar charge controlle
- MPPT solar charge controller eSmart4
- EXPLORER-M MPPT Solar Smart Digital Controller
- EXPLORER MPPT Solar Smart Digital Controller
- RUNNER MPPT Solar Smart Digital Controller
- GALAXY high power series MPPT solar controller
- MARS outdoor series MPPT solar controller
- eSMART series MPPT solar controller
- MASTER series MPPT solar controller
- Accessories
- (out of product)WISER series MPPT solar controller
- (out of production)Inverter SP Series 350W-20000W
- (Has been removed)
- (out of production)I-Panda SPC Series Inverter
- Certifications
-
- Subscribe
-
Get email updates on new products
- Hot Products
- Contact Us
-
Tel: + 86-755-23091101&+86-755-23091100
Fax: + 86-755-23091102
Information: info@ipandee.com
address: Floor 2, building A2, LiLang Software Park, No. 31, Bulan Road, Nanwan street, Longgang District, Shenzhen
China Post code: 518000 Contact Now
- Follow us
- News
-
-
Why is the inverter starting voltage higher than the minimum voltage?
In the photovoltaic grid-connected inverter, one parameter is strange, that is, the inverter input starting voltage. This voltage is about 30V higher ... -
How to solve the AC inverter overvoltage problem?
just nowPhotovoltaicOn-grid power generation is becoming more and more popular, and ordinary people's homes can see PV power plants in real time. Howe... -
The difference between an improved sine wave and a pure sine wave inverter
This article describes the difference between an improved sine wave and a pure sine wave inverter. ModifiedSine Pure Wave: The most common general pur... -
Europe's first waste photovoltaic panel recycling plant
Solar panels have a service life of 20 to 30 years. Along with the mass production of the global solar energy manufacturing industry in the past few y... -
The world's top ten PV inverter companies
The inverter is also called the power regulator. According to the use of the inverter in the photovoltaic power generation system, it can be divided i... -
Why should the inverter stop working when the grid is out of power?
Some people install a photovoltaic system, they will have a mentality of "even if the power grid is cut off, if there is a sun, and their homes can us... -
What is the difference between MPPT function and solar inverter without MPPT function?
The MPPT controller utilizes maximum power point tracking technology to extract the maximum power from the solar array to charge the battery. The maxi... -
Scientists have discovered that sand can make solar cell silicon materials
According to a report by the Kyodo News Agency on November 6th, visiting professors of the University of Tokyo, Sugawara, and others opened a joint st... -
Domestic energy storage market competition pattern
Energy storage as a new market for many battery manufacturers in China andInverterVendors bring the opportunity to expand new affairs and change the p... -
How to build a photovoltaic power station
1. What kind of roof is suitable for the installation of photovoltaic power plants? The most suitable for the installation of domestic photovoltaic ro...
-
Factory price 24v 1000w hybrid solar inverter with mppt charge controller
- Place of Origin:Shenzhen China (Mainland)
- Brand Name: I-Panda
- Model Number: I-P-HPC-1000W
- Type: DC/AC Inverters
- Technology: CPU control
- Output Power: 1000w
- Output Type: Pure Sine Wave form
- DC Input Voltage: 48V
- AC Input Voltage: 100/110/220/230/240V
- Output Voltage: 100/110/220/230/240V
Factory price 24v 1000w hybrid solar inverter with mppt charge controller
Introduction
This series of product is a module design of inverter and built-in MPPT controller, which has the advantages of high conversion efficiency, low power consumption and strong load-carrying ability. With intelligent control, customers can set charging mode, (Utility as complementary power) AC first mode or DC first mode, timed inversion mode and timed utility mode, timed on/off sleep mode. This is the currently the most advanced inverter & controller hybrid in the world.
Application
1. Off-grid solar power system
2. Solar power system with utility as complementary power
Feature
1. Easy to install. To configure a solar system, customers only need to connect it with solar panels and batteries
2. CPU management ,intelligent control,modular design, User-friendly LCD display
3. Built-in MPPT controller, high charging efficiency
4. Low power consumption, high conversion efficiency
5. Intellectual,multi-function, convenient for customers with different using environment to fully use the solar energy
6. External battery connection, convenient to expand back-up power time
7. Strong load-carrying ability, low failure rate, easy maintenance and long service life (under proper operation, it may be as long as 5 years)
8. Perfect protection: low voltage protection, over voltage protection, overheat protection, short-circuit protection, overloads protection
9. CE / EMC / LVD/ RoHS Approvals
10. Two years warranty, life-long technical supports
Function
1. Charging function
There are 2 modes as shown bellow:
1.1 PV charge the battery, utility will not: when PV and utility are both connected to the machine, only the PV will charge the battery when there is sunlight
1.2 Both PV and utility will charge the battery: when PV and utility are both connected to the machine, AC (utility) will charge the battery. In the meanwhile, PV will also charge the battery if there is sunlight.
2. Utility as complementary power function
There are 2 kinds of complementary modes, shown as bellow:
2.1 AC first , DC standby UPS mode
When both utility and battery are connected to the machine, utility will supply power to the loads prior to the battery. When utility is cut off, the battery will automatically continue to supply power.
Steps are as follows:
Step 1: When utility power is available, it will output directly after voltage
being stabilized and charge batteries at the same time.
Step 2: When utility power is cut off suddenly, the inverter will convert
DC power to AC power automatically to ensure uninterrupted
power supply within 5ms.
Step 3: When utility power becomes available again, it will automatically
transfer to utility supplying power to loads and charge batteries
at the same time.
Photos :
Parameter:
Parameter Model |
1000W |
|||
Rated Output Power |
1000W |
|||
Peak Power |
2000W |
|||
Battery (Lead-acid battery) |
24V |
|||
Charging Parameter |
||||
Charge Mode(setting) |
PV charge |
|||
PV charge + utility charge |
||||
MPPT Solar Controller |
Voltage |
24V |
||
Current |
20A |
|||
Max PV Input Voltage |
100V |
|||
PV Charge Efficiency |
95%~99% |
|||
Max PV Input Power |
568W |
|||
Utility |
AC Charge Current |
0~15A |
||
Charge Mode |
3-Stage Charging |
|||
Inversion parameter |
||||
AC Output |
Voltage |
220V±3% or 230V±3 or 240V±3% or 100V±3% |
||
Frequency |
50Hz±0.5 or 60Hz±0.5 (optional) |
|||
Output wave type |
Pure sine wave output, waveform distortion rate≤3 |
|||
Overload ability |
>120% 1 min, >130% 10s |
|||
Power Consumption (under normal working mode) |
0.4A |
|||
Power Consumption (under sleep mode) |
1-6W |
|||
Inverter Conversion Efficiency |
85%~92% |
|||
Utility Mode |
||||
AC Input |
Voltage |
220V±35% or 110V+35%(optional) |
||
Frequency |
The same as utility |
|||
AC Output |
Voltage |
220V±5% or 110V+5%(optional) |
||
Frequency |
The same as utility |
|||
Overload Ability |
>120% 1 min,>130% 10s |
|||
(AC first or DC first) priority |
||||
UPS Output(setting) |
AC first, DC standby |
|||
DC first, AC standby |
||||
Switch Time |
<5ms (AC to DC / DC to AC) |
|||
Power On |
Set by users |
|||
Timed open / close AC output automatically |
||||
General Parameter |
||||
Display |
Display Mode |
LCD+LED |
||
Display Information |
Input voltage, output voltage, output frequency, battery capacity, Load condition, Status Information |
|||
Protection |
Overload output, short-circuit, high-voltage input, low-voltage input, overheat |
|||
Environment |
Temperature |
-10℃~50℃ |
||
humidity |
10%~90% |
|||
Altitude |
≤4000m |
|||
Size W×D×H(mm) |
438*208*413 |
|||
Packing Size W×D×H(mm) |
520*310*460 |
|||
Net Weight (kg) |
15 |
|||
Gross Weight (kg) |
16 |
Remarks:
The “optional” parameter can be set as per customer’s requirement
The above is our standard parameter. Subject to change without prior notice.
We have our own professional inverter and controller R&D team and we provide technical support and OEM service.
Connection Diagram:
Others :
Please refer to the outline design, technical documents, product brochures, etc.
Made by Engineering Department, May 15, 2014, 2nd Edition
Tel:+86 15002089033
Contact Person:Wenshen Huang
PDF Show:PDF