- Browse Categories
- EMMPT48 series MPPT solar charge controller
- The Explorer-NS series MPPT solar charge controlle
- MPPT solar charge controller eSmart4
- EXPLORER-M MPPT Solar Smart Digital Controller
- EXPLORER MPPT Solar Smart Digital Controller
- RUNNER MPPT Solar Smart Digital Controller
- GALAXY high power series MPPT solar controller
- MARS outdoor series MPPT solar controller
- eSMART series MPPT solar controller
- MASTER series MPPT solar controller
- Accessories
- (out of product)WISER series MPPT solar controller
- (out of production)Inverter SP Series 350W-20000W
- (Has been removed)
- (out of production)I-Panda SPC Series Inverter
- Certifications
-
- Subscribe
-
Get email updates on new products
- Hot Products
- Contact Us
-
Tel: + 86-755-23091101&+86-755-23091100
Fax: + 86-755-23091102
Information: info@ipandee.com
address: Floor 2, building A2, LiLang Software Park, No. 31, Bulan Road, Nanwan street, Longgang District, Shenzhen
China Post code: 518000 Contact Now
- Follow us
- News
-
-
Why is the inverter starting voltage higher than the minimum voltage?
In the photovoltaic grid-connected inverter, one parameter is strange, that is, the inverter input starting voltage. This voltage is about 30V higher ... -
How to solve the AC inverter overvoltage problem?
just nowPhotovoltaicOn-grid power generation is becoming more and more popular, and ordinary people's homes can see PV power plants in real time. Howe... -
The difference between an improved sine wave and a pure sine wave inverter
This article describes the difference between an improved sine wave and a pure sine wave inverter. ModifiedSine Pure Wave: The most common general pur... -
Europe's first waste photovoltaic panel recycling plant
Solar panels have a service life of 20 to 30 years. Along with the mass production of the global solar energy manufacturing industry in the past few y... -
The world's top ten PV inverter companies
The inverter is also called the power regulator. According to the use of the inverter in the photovoltaic power generation system, it can be divided i... -
Why should the inverter stop working when the grid is out of power?
Some people install a photovoltaic system, they will have a mentality of "even if the power grid is cut off, if there is a sun, and their homes can us... -
What is the difference between MPPT function and solar inverter without MPPT function?
The MPPT controller utilizes maximum power point tracking technology to extract the maximum power from the solar array to charge the battery. The maxi... -
Scientists have discovered that sand can make solar cell silicon materials
According to a report by the Kyodo News Agency on November 6th, visiting professors of the University of Tokyo, Sugawara, and others opened a joint st... -
Domestic energy storage market competition pattern
Energy storage as a new market for many battery manufacturers in China andInverterVendors bring the opportunity to expand new affairs and change the p... -
How to build a photovoltaic power station
1. What kind of roof is suitable for the installation of photovoltaic power plants? The most suitable for the installation of domestic photovoltaic ro...
-
4000W pure sine wave inverter-I-Panda SP inverter series
- Introduction
- When under inversion mode,this series of inverters can be set to normal working mode and sleep mode. And when under utility mode, it has Auto Voltage Regulation (AVR) function, utility charging function (only when AC first) and UPS function (AC first or DC first, optional). This multifunction low frequency pure sine wave inverter, which has the advantages of stable quality, strong load-carrying ability and anti-poor environment ability, Long service life, is the second generation of our low frequency pure sine wave inverter.
Application
1. Back-up UPS system for industrial,commercial, household,etc
2. Mobile power and standby power for areasthat are lack of utility.
3. Off-grid solar & wind power system
3.1 Simple Off-grid solar & wind powersystem
3.2 AC first Off-grid solar & windpower system
3.3 DC first Off-grid solar & windpower system
Features
1. pure sine wave output, full power
2. CPU management and control,modulardesign
3. LCD display,can visually display variousparameters
4. Multifunction design,can set a varietyof working mode
5. External battery connection, convenientto expand use time and back-up power time; user can connect as many batteriesas needed
6. With super load carrying ability andhigh load capacity, this series of inverters can not only drive resistance load; but also various kinds ofinductive loads, such as motor, air conditioner, electric drills, fluorescentlamp, gas lamp, etc. It can drive almost any kinds of load
7. Low frequency circuit design, goodsystem stability, low failure rate and long service life (under properoperation, it may be as long as 5 years)
8. Perfect protection: low voltageprotection, over voltage protection, overheat protection, short-circuitprotection, overloads protection; alarm alert
9. CE / EMC / LVD/ RoHS Approvals.
10. Two years warranty, life-long technicalsupports
Function
1. Sole inversion function under inversion mode (only connected to battery),can be set to normal operatingmode and sleep mode.
1.1 Normal working mode:FREQUNCY in the LCD display is setas 01. No matter whether there are AC loads connected to the inverter or not,the inverter’s outputterminal will always have voltage ready to supply power to the loads. Underthis mode, the LCD will be displayed as bellow:
1.2 Sleep mode:FREQUNCY in the LCD display is setas 02. If the power of the loads that connected to the inverter is lower than5% of the inverter’s rated power, there will be no output from the inverter. That is tosay, only the chip of inverter is working under such condition and the powerconsumption is only 1-6W; If the power of the loads that connected to theinverter is higher than 5% of the inverter’s rated power, then the inverterwill automatically start the inversion function and supply power to the loadswithin 5s. As shown below:
2. UPS function under utility mode(connected to battery and utility .Can beset as utility first, battery standby mode and battery first, utility standbymode).
2.1 Utility first, battery standby UPSmode: FREQUENCY in the LCD display is set as 01. When both utility and batteryare connected to the inverter, utility will supply power to the loads prior tothe battery. When utility is cut off, the battery will automatically continueto supply power after inversion.
Steps are as follows:
Step 1: When utility power is available, itwill output directly after voltagebeing stabilized and charge batteries at thesame time.
Step 2: When utility power is cut off suddenly,the inverter will convert DC power to AC power automatically to ensureuninterrupted power supply within 5ms.
Step 3: When utility power becomesavailable again, it will automatically transfer to utility supplying power toloads and charge batteries at the same time.
See Workflow as below.
LCD displayed as bellow:
2.2 Battery first, utility standby UPSmode: FREQUENCY in the LCD display is set as 03. When both utility and battery are connectedto the inverter, battery will supply power to the loads prior to utility. Whenbattery capacity is not enough, utility will continue to supply powerautomatically.
Steps are as follows:
Step 1: When battery has enough power, itwill supply power to the loads directly
Step 2: When battery does not have enoughpower, it will automatically transfer to utility supplying power to the loads
Step 3: After the battery is fully charged(e.g. by solar or wind charge controller), it will then automatically transferto battery supplying power to the loads.
See Workflow as below.
Model Parameter |
6000VA |
|
Rated Output Capacity |
4000W |
|
Peak Power |
8000W |
|
Battery Voltage(DC) |
48V/96V/192V(optional) |
|
Size W×D×H(mm) |
420*260*605 |
|
Packing Size W×D×H(mm) |
440*280*625 |
|
Net Weight (kg) |
50 |
|
Gross Weight (kg) |
55 |
|
General Parameter |
||
Working Mode (Setting) |
1 |
Utility First, Battery Standby |
2 |
Sleep Mode,no utility,load’s power higher than 5% of rated power, start to work automatically |
|
3 |
Battery first, utility standby |
|
AC Input |
Voltage |
220V±35% or 110V+35%(optional) |
Frequency |
50Hz±3% or 60Hz±3% (optional) |
|
AC Output |
Voltage |
220V±3% or 230V±3 or 240V±3% or 100V±3% |
or 110V±3% (optional) |
||
Frequency |
50Hz±0.5 or 60Hz±0.5 (optional) |
|
Battery charge |
AC Charge Current |
0~15A |
Charge Time |
Depend on battery capacity and quantity |
|
Battery Protection |
Automatic detection, Charge and discharge protection,Intelligent Management |
|
Display |
Display Mode |
LCD |
Display Information |
Input voltage,output voltage,output frequency,battery capacity,Load condition,Status Information |
|
Output Wave Type |
Pure sine wave output,waveform distortion rate≤3 |
|
Overload Ability |
>120% 1 min,>130% 10s |
|
Power Consumption |
Sleep Mode |
1~6W |
Normal Mode |
1~3A |
|
Conversion Efficiency |
80%~90% |
|
Transfer Time |
<5ms (AC to DC / DC to AC) |
|
Protection |
Overload output,short-circuit,high-voltage input,low-voltage input,overheat |
|
Environment |
Temperature |
-10℃~50℃ |
Humidity |
10%~90% |
|
Altitude |
≤4000m |
Remark
The “optional” parameter can be set as percustomer’s requirement
The above is our standard parameter.Subject to change without prior notice.
We have our own professional inverter andcontroller R&D team and we provide technical support and OEM service.
Others
Please refer tothe outline design, technical documents, product brochures, etc.
Made byEngineering Department May 5, 2014 2nd Edition
Tel:+86-15002089033
Contact Person:Henry Feng
PDF Show:PDF