- Browse Categories
- EMMPT48 series MPPT solar charge controller(1)
- The Explorer-NS series MPPT solar charge controlle(1)
- MPPT solar charge controller eSmart4(1)
- EXPLORER-M MPPT Solar Smart Digital Controller(15)
- EXPLORER MPPT Solar Smart Digital Controller(12)
- RUNNER MPPT Solar Smart Digital Controller(9)
- GALAXY high power series MPPT solar controller(12)
- MARS outdoor series MPPT solar controller(10)
- eSMART series MPPT solar controller(23)
- MASTER series MPPT solar controller(28)
- Accessories(3)
- (out of product)WISER series MPPT solar controller(12)
- (out of production)Inverter SP Series 350W-20000W(110)
- (out of production)I-Panda SPC Series Inverter(70)
- (Has been removed)(517)
- Certifications
- Subscribe
-
Get email updates on new products
- Contact us
- Tel: + 86-755-23091101&+86-755-23091100
Fax: + 86-755-23091102
Information: info@ipandee.com
address: Floor 2, building A2, LiLang Software Park, No. 31, Bulan Road, Nanwan street, Longgang District, Shenzhen
China Post code: 518000Contact Now
- Share
Products
The pure sine wave inverter-I-Panda SP inverter series
- Introduction
- When under inversion mode,this series of inverters can be set to normal working mode and sleep mode. And when under utility mode,it has Auto Voltage Regulation (AVR) function, utility charging function (only when AC first) and UPS function (AC first or DC first,optional). This multifunction low frequency pure sine wave inverter, which has the advantages of stable quality, strong load-carrying ability and anti-poor environment ability, Long service life, is the second generation of our low frequency pure sine wave inverter.
Application
1. Back-up UPS systemfor industrial, commercial, household,etc
2. Mobile power andstandby power for areas that are lack of utility.
3. Off-grid solar &wind power system
3.1 SimpleOff-grid solar & wind power system
3.2 AC firstOff-grid solar & wind power system
3.3 DC firstOff-grid solar & wind power system
Features
1. pure sine wave output,full power
2. CPU management andcontrol,modulardesign
3. LCD display,can visually displayvarious parameters
4. Multifunction design,can set a variety ofworking mode
5. External battery connection,convenient to expand use time and back-up power time; user can connect as manybatteries as needed
6. With super load carrying ability and high loadcapacity, this series of inverters cannot only drive resistance load; but also various kinds of inductive loads, suchas motor, air conditioner, electric drills, fluorescent lamp, gas lamp, etc. Itcan drive almost any kinds of load
7. Low frequency circuit design, good system stability, low failure rate andlong service life (under proper operation, it may be as long as 5 years)
8. Perfect protection:low voltage protection, over voltage protection, overheat protection, short-circuitprotection, overloads protection; alarm alert
9. CE / EMC / LVD/ RoHS Approvals.
10. Two yearswarranty, life-long technical supports
Function
1. Soleinversion function under inversion mode (only connected to battery),can be set to normal operating modeand sleep mode.

1.1 Normal working mode:FREQUNCY in the LCD display is set as01. No matter whether there are AC loads connected to the inverter or not, theinverter’s output terminal will always have voltage ready to supply power tothe loads. Under this mode, the LCD will be displayed as bellow:
1.2 Sleepmode:FREQUNCY in the LCD displayis set as 02. If the power of the loads that connected to the inverter is lowerthan 5% of the inverter’s rated power, there will be no output from theinverter. That is to say, only the chip of inverter is working under suchcondition and the power consumption is only 1-6W; If the power of the loadsthat connected to the inverter is higher than 5% of the inverter’s rated power,then the inverter will automatically start the inversion function and supplypower to the loads within 5s. As shown below:
2. UPSfunction under utility mode(connectedto battery and utility .Can be set as utility first, battery standby mode and battery first, utility standby mode).
2.1 Utility first,battery standby UPS mode: FREQUENCY in the LCD display is set as 01. Whenboth utility and battery are connected to the inverter, utility willsupply power to the loads prior to the battery. When utility is cut off, thebattery will automatically continue to supply power after inversion.
Steps are as follows:
Step 1: When utility power is available, itwill output directly after voltagebeing stabilized and charge batteriesat the same time.
Step2: When utility power is cut off suddenly, the inverter will convert DC power to AC power automatically toensure uninterrupted power supply within 5ms.
Step 3: When utility power becomes availableagain, it will automatically transfer to utility supplying powerto loads and charge batteries at the same time.
SeeWorkflow as below.
LCD displayed as bellow:

2.2 Battery first, utility standby UPS mode: FREQUENCY in the LCDdisplay is set as 03. When both utilityand battery are connected to the inverter, battery will supply power to theloads prior to utility. When battery capacity is not enough, utility willcontinue to supply power automatically.
Steps are as follows:
Step 1: When battery has enough power, it will supply powerto the loads directly
Step 2: When battery does not have enough power, it willautomatically transfer to utility supplying power to the loads
Step 3: After the battery is fully charged (e.g. by solar orwind charge controller), it will then automatically transfer to batterysupplying power to the loads.
See Workflow as below.
LCD displayed as bellow:
Parameter
Mode Parameter |
500VA |
700VA |
1000VA |
1500VA |
2000VA |
3000VA |
4000VA |
|
Rated Output Capacity |
350W |
500W |
700W |
1000W |
1500W |
2000W |
3000W |
|
Peak Power |
700W |
1000W |
1500W |
2000W |
3000W |
4000W |
6000W |
|
Battery Voltage(DC) |
12V/24V(optional) |
24V |
24V/48V/96V(optional) |
|||||
Size W×D×H(mm) |
335*165*375 |
350*220*460 |
||||||
Packing Size W×D×H(mm) |
355*185*395 |
370*240*480 |
||||||
Net Weight (kg) |
7 |
8 |
12 |
14 |
20 |
23 |
29 |
|
Gross Weight (kg) |
8 |
9 |
13 |
16 |
22 |
25 |
31 |
|
|
||||||||
Model |
5000VA |
6000VA |
7000VA |
10kVA |
15kVA |
20kVA |
30kVA |
|
Rated Output Capacity |
3500W |
4000W |
5000W |
7000W |
10000W |
15000W |
20000W |
|
Peak Power |
7000W |
8000W |
10000W |
14000W |
20000W |
30000W |
40000W |
|
Battery Voltage(DC) |
48V/96V/192V(optional) |
96V/192V(optional) |
192V |
|||||
Size W×D×H(mm) |
420*260*605 |
420*280*625 |
||||||
Packing Size W×D×H(mm) |
440*280*625 |
440*300*645 |
||||||
Net Weight (kg) |
31 |
50 |
50 |
55 |
85 |
105 |
125 |
|
Gross Weight (kg) |
33 |
55 |
60 |
65 |
95 |
115 |
135 |
|
General Parameter |
||||||||
Working Mode (Setting)
|
1 |
Utility First, Battery Standby |
||||||
2 |
Sleep Mode,no utility,load’s power higher than 5% of rated power, start to work automatically |
|||||||
3 |
Battery first, utility standby |
|||||||
AC Input |
Voltage |
220V±35% or 110V+35%(optional) |
||||||
Frequency |
50Hz±3% or 60Hz±3% (optional) |
|||||||
AC Output |
Voltage |
220V±3% or 230V±3 or 240V±3% or 100V±3% |
||||||
or 110V±3% (optional) |
||||||||
Frequency |
50Hz±0.5 or 60Hz±0.5 (optional) |
|||||||
Battery charge |
AC Charge Current |
0~15A |
||||||
Charge Time |
Depend on battery capacity and quantity |
|||||||
Battery Protection |
Automatic detection, Charge and discharge protection,Intelligent Management |
|||||||
Display |
Display Mode |
LCD |
||||||
Display Information |
Input voltage,output voltage,output frequency,battery capacity,Load condition,Status Information |
|||||||
Output Wave Type |
Pure sine wave output,waveform distortion rate≤3 |
|||||||
Overload Ability |
>120% 1 min,>130% 10s |
|||||||
Power Consumption |
Sleep Mode |
1~6W |
||||||
Normal Mode |
1~3A |
|||||||
Conversion Efficiency |
80%~90% |
|||||||
Transfer Time |
<5ms (AC to DC / DC to AC) |
|||||||
Protection |
Overload output,short-circuit,high-voltage input,low-voltage input,overheat |
|||||||
Environment |
Temperature |
-10℃~50℃ |
||||||
Humidity |
10%~90% |
|||||||
Altitude |
≤4000m |
- The “optional” parameter can be set as per customer’s requirement
- The above is our standard parameter. Subject to change without prior notice.
- We have our own professional inverter and controller R&D team and we provide technical support and OEM service.
Others:
- Please refer to the outline design, technical documents, product brochures, etc.
- Made by Engineering Department, May 5, 2014, 2nd Edition