Browse Categories
EMMPT48 series MPPT solar charge controller
The Explorer-NS series MPPT solar charge controlle
MPPT solar charge controller eSmart4
EXPLORER-M MPPT Solar Smart Digital Controller
EXPLORER MPPT Solar Smart Digital Controller
RUNNER MPPT Solar Smart Digital Controller
GALAXY high power series MPPT solar controller
MARS outdoor series MPPT solar controller
eSMART series MPPT solar controller
MASTER series MPPT solar controller
Accessories
(out of product)WISER series MPPT solar controller
(out of production)Inverter SP Series 350W-20000W
(Has been removed)
(out of production)I-Panda SPC Series Inverter
Certifications
Contact Us
Tel: + 86-755-23091101&+86-755-23091100  
Fax: + 86-755-23091102   
Information: info@ipandee.com
address: Floor 2, building A2, LiLang Software Park, No. 31, Bulan Road, Nanwan street, Longgang District, Shenzhen   
China Post code: 518000
Contact Now
Follow us
News
Your position: Home > Category > (out of production)Inverter SP Series 350W-20000W > 6kw dc 96V to ac 220V low frequency pure sine wave solar water pump inverter
6kw dc 96V to ac 220V low frequency pure sine wave solar water pump inverter6kw dc 96V to ac 220V low frequency pure sine wave solar water pump inverter6kw dc 96V to ac 220V low frequency pure sine wave solar water pump inverter6kw dc 96V to ac 220V low frequency pure sine wave solar water pump inverter

6kw dc 96V to ac 220V low frequency pure sine wave solar water pump inverter

  • Application
  • 1、Back-up UPS system for industrial, commercial, household,etc
  • 2、Removable power and standby power for areas that are lack of utility.
  • 3、Off-grid solar or wind power system
  •   3.1、Off-grid solar or wind power system
  •   3.2、AC first Off-grid solar or wind power system
  •   3.3、DC first Off-grid solar or wind power system

Introduction

In DC/AC inversion mode, users can set this series of inverters to normal working mode or sleep mode. In utility mode, it has Auto Voltage Regulation (AVR) function, utility charging function (AC first model) and UPS function. This multifunctional low frequency pure sine wave inverter has the advantages of stable quality, strong load-carrying ability and long service life. It also can work in poor environment. It is the second generation of our low frequency pure sine wave inverter I-P-XD-series.

Features

1、pure sine wave output, full power

2、CPU control,intelligent control,modular design

3、LCD display various parameters

4、Multifunction design (AVR, UPS), extra charger is not needed and electric      appliances can be protected.

5、External battery connection, it’s convenient for users to expand use time and back-up power time

6、With super load carrying ability and high load capacity, this series of  inverters can not only drive resistance load; but also various kinds of inductive loads, such as motor, air conditioner, electric drills, fluorescent lamp, gas lamp.

7、Low frequency circuit design, stable quality, low failure rate and long service life (under proper operation, it can last at least 5 years)

8、Perfect protection: low voltage protection, high voltage protection, over temperature protection, short-circuit protection, overload protection, alarm alert

9、CE / EMC / LVD/ RoHS Approvals

10、Two years warranty, life-long technical support

Function 

1、DC to AC inversion function in inversion mode (only connected with batteries and loads) ,users can set it to normal working mode or sleep mode

1.1、Normal working mode:FREQUNCY in the LCD display is set to 01. No matter it’s connected AC loads or not, the inverter always convert DC to AC.  It’s ready to supply power to the AC loads. In this mode, the LCD will display output voltage as bellow:


1.2、Sleep mode:FREQUNCY in the LCD display is set as 02.If the power of the connected AC loads is lower than 5% of the inverter’s rated power, there will be no output from the inverter. Only the chip of inverter is working. The power consumption of the inverter is only 1-6W. The LCD shows the output voltage 0. If the power of the connected loads is over 5%,then the inverter will automatically convert DC to AC to supply power for the loads within 5s. The LCD shows the output voltage. As shown below:
                                  Load’s power<5% of inverter’s rated power                 Load’s power>5% of inverter’s rated power 

2UPS function  When the inverter is connected to battery and utility, users can set it to utility first (AC first) battery standby mode or battery first (DC first)utility standy mode. 

2.1、Utility first (AC first) battery standby mode : FREQUENCY in the LCD display is set to 01. When utility and battery are connected to the inverter, utility will supply power to the loads prior. When utility is cut off, the battery will automatically continue to supply power via power inverter.

   Steps are as follows:

   Step 1: When utility is available, it will drive the loads directly after voltage being stabilized and at the same time charge batteries via power inverter .

   Step 2: When utility is cut off, the inverter will convert DC to AC automatically to ensure uninterrupted power supply within 5ms.

   Step 3: When utility is available again, inverter will automatically transfer to utility supplying power to loads and charge batteries via power inverter at the same time.

 See Workflow as below. 

LCD displayed as bellow:
                  
Utility supply power and charge battery                   Utility is unavailable, battery supply power 

2.2、Battery first (DC first)utility standby UPS mode: FREQUENCY in the LCD display is set as 03. When utility and battery are connected to the inverter, battery will supply power to the loads prior to utility. When battery capacity is not enough, utility will continue to supply power automatically.

Steps are as follows:

Step 1: When battery is available, it will drive the AC loads via power inverter.

Step 2: When battery does not have enough power, it will automatically transfer to utility supplying power to the loads

Step 3: After the battery is fully charged (e.g. by solar or wind charge controller), it will automatically transfer to battery supplying power to the loads via power inverter.

 See Workflow as below 


LCD displayed as bellow:

                     
     Battery is available                            Battery is not available,utility supply power 

Parameter

Model   

Parameter

                           8000VA

Rated Output Capacity

6000W

Peak Power

12000W

Battery Voltage(DC)

96V/192V(optional)

Size W×D×H(mm)

420*260*605

Packing Size W×D×H(mm)

440*280*625

Net Weight (kg) 

55

Gross Weight (kg) 

65

General Parameter

Working Mode

1

Utility first (AC first) battery standby mode

(Setting)

2

Sleep Mode,no utility,load’s power higher than 5% of  inverter rated output power,it will start to work automatically

 

3

Battery first (DC first)utility standby UPS mode

AC Input

Voltage

220V±35% or 110V+35%(optional)

Frequency

50Hz±3% or 60Hz±3% (optional)

AC Output

Voltage

220V±3% or 230V±3 or 240V±3% or 100V±3% or 110V±3% (optional)

Frequency

50Hz±0.5 or 60Hz±0.5 (optional)

Battery charge

AC Charge Current

0~15A

Charge Time

Depend on battery capacity and quantity

Battery Protection

Automatic detection, Charge and discharge protection,Intelligent Management

Display

Display Mode

LCD

Display Information

Input voltage,output voltage,output frequency,battery capacity,Load condition,Status Information

Output Wave Type

Pure sine wave output,Total Harmonic Distortion THD≤3

Overload Ability

>120% 1 min,>130% 10s

Power Consumption

Sleep Mode

1~6W

Normal Mode

1~3A

Conversion Efficiency

80%~90%

Transfer Time

<5ms (AC to DC / DC to AC)

Protection

Overload ,Short-circuit,High input voltage,Low input voltage,Overheat

Environment

Temperature

-10℃~50℃

Humidity

 10%~90%

Altitude

≤4000m


The above is our standard parameter. Subject to change without prior notice. 
We have our own professional inverter and controller R&D team and we 
provide technical support and OEM ODM service. 
Others 
Please see the outline of the design,technical documents,user manuals,product brochures, etc.Research and development department made 2th edition on May 5, 2014.



Company






Shenzhen ipandee New Energy Technology & Science Co., Ltd

Tel:+86 15002089033

Contact Person:Wenshen Huang

PDF Show:PDF

Send Inquiry
captcha
https://kefu5.cckefucloud.com/vclient/chat/?websiteid=p9rjd9g58z6e70x5e6vpx31vpm2kwyb4&wc=39157e7a&clerkid=906266