LCD display 12V/24V/36V/48V 80A MPPT Solar ControllerLCD display 12V/24V/36V/48V 80A MPPT Solar ControllerLCD display 12V/24V/36V/48V 80A MPPT Solar ControllerLCD display 12V/24V/36V/48V 80A MPPT Solar Controller

LCD display 12V/24V/36V/48V 80A MPPT Solar Controller

  • Brand Name: I-Panda
  • Model Number: I-P-MASTER-DC12/24/36V/48V-80A
  • Rated Voltage: DC12V/24V/36V/48V auto recognition
  • Peak effeciency: 99% 
  • Color: green/blue
  • Display: LCD+LED
  • 4 Smart key buttons: Yes
  • Charge mode: mppt
  • Communication port: RS232 and LAN
  • Data set and Monitor: Yes
  • 3 charge stages: fast charge, constant voltage, floating charge
  • Battery type: General type; others be defined by users
Introduction: 
This is a Maximum Power Point Tracking(MPPT) function with high efficiency MPPT charge controller. It has many advantages such as self cooling, system voltage automatic recognition, wide rang of PV input,bcharge for all kinds of batteries, intelligent discharge control, RS232 / LAN communication function etc. It is the most high-end product in solar market. 

Feature: 
1.MPPT charge mode, conversion efficiency up to 99%. 
2.12V/24V/36V/48V battery system automatic recognition, convenient for customers to use. 
3.Maximum PV input voltage up to DC150V. 
4.Controllers can be connected in unlimited parallels. 
5.Memory function, to save the setting, date, time, generating capacity and so on . 
6.Charge mode: three stages (fast charge ,constant charge ,floating charge). To extend the life span of the battery 
7.Discharge mode: ON/OFF mode, double time control mode, PV voltage control mode ,PV voltage+time delay mode and so on . 
8.Recommended battery types: sealed lead acid, Vented, Gel, NiCd battery. Other types of the batteries can also be defined, such as lithium battery etc. 
9.Most information could be provide by LCD and LED like: model no., PV input voltage,battery type,battery voltage,charging current,charging power,working status and so on. Also customer's information like company name,website and logo can be added to Solar Eagle software. 
10.RS232 and LAN communication port, IP and Gate address could be defined by the users and it can be used all around the world. And communication protocol can be provided to help customer manage all information . 
11.Provide professional upper computer software, it could show work status and set parameters of the discharge system. 
12.With intelligent design, customers can enjoy a lifelong upgrade online service 
13.Adopting the well-known brand components, the devices can suffer the temperature at least 105℃.The lifespan is designed to use for 10 years in theory. 
14.Compliance with the 2002/95/EC environment protecting demand, doesn't include the cadmium, hydride and fluoride etc . 
15.CE,ROHS,FCC certifications approved, other certifications can also be made  based on different requirements. 
16. 2 years warranty and 3~10 years extended technical service. 

Parameter:

MPPT controller Model:

Master-80A/100A Series

80A

100A

Charge Mode

MPPT(Maximum Power Point Tracking)

Charge Method

3 stages: fast charge(MPPT),constant voltage, floating charge

System Type

DC12V/24V/36V/48V

Automatic recognition

Soft Start Time

DC12V/24V/36V/48V

≤10S

Conversion Efficiency

DC12V/24V/36V/48V

≥96.5%,≤99%

PV Modules Utilization Rate

DC12V/24V/36V/48V

≥99%

System Voltage

12V system

DC9V~15V

24V system

DC18V~28V

36V system

DC32V~40V

48V system

DC42V~60V

Error system

The battery voltage is not in above range when the controller is switched on

PV Input Characteristics

MPPT Working Voltage and Range

12V system

DC16V~DC150V

24V system

DC30V~DC150V

36V system

DC45V~DC150V

48V system

DC60V~DC150V

Input Low Voltage recovery Point

12V system

DC22V

24V system

DC34V

36V system

DC50V

48V system

DC65V

Input Over voltage Protection Point

DC12V/24V/36V/48V

DC150V

Input Over voltage Recovery Point

DC12V/24V/36V/48V

DC145V

Max. PV Power

12V system

960W

1200W

24V system

1920W

2400W

36V system

2880W

3600W

48V system

3840W

4800W

Charge characteristic

Selectable Battery Types (Default type is GEL battery)

DC12V/24V/36V/48V

Sealed lead acid, vented Gel, NiCd battery (Other types of the batteries also can be defined)

Charge mode

DC12V/24V/36V/48V

constant current-constant voltage-floating charge

Constant Voltage

DC12V/24V/36V/48V

Please check the charge voltage according to the battery type form.

Floating Charge Voltage

DC12V/24V/36V/48V

Rate charge current

DC12V/24V/36V/48V

80A

100A

Current-limiting Protection

DC12V/24V/36V/48V

85A

105A

Temperature Factor

DC12V/24V/36V/48V

±0.02%/℃

Temperature Compensation

DC12V/24V/36V/48V

14.2V-(The highest temperature-25℃)*0.3

Output Ripples(peak)

DC12V/24V/36V/48V

200mV

Charger voltage accuracy

DC12V/24V/36V/48V

≤±1.5%

Remark:Above is company's standard parameters;

Product Parts:

NO.

Quantity

Description

   1

1PC

MPPT Solar controller(Blue,Green or White)

2

2 pc

hangers(To install the controller on the wall )

3

8 set

Screw

(To keep the hangers into the controller )

4

1 pc

RJ45 turn to RS232 communication cable

5

1 pc

Temperature sensing wire

6

1 pc

CD

7

1 pc

User manual

 


 

 


 

The Main Information of MPPT

 



Setting page:

Note: All above information is a sample which is the working state of Master in some time . In different working stage the parameters will change, like working mode , charge current ,charge mode ,charge power and so on ; In the fault mode it will show fault mode ;

Upper Computer Software and Test Software 

 

                                     The interface of upper computer software working state



                                                 The interface of test software working state

MPPT Connection:











Shenzhen I-Panda New Energy Technology & Science Co., Ltd

Tel:+86-15118053527

Contact Person:bella Zhan

Send your inquiry directly to us
( 0 / 3000 )