- Parcourir les catégories
- EMMPT48 series MPPT solar charge controller
- The Explorer-NS series MPPT solar charge controlle
- MPPT solar charge controller eSmart4
- EXPLORER-M MPPT Solar Smart Digital Controller
- EXPLORER MPPT Solar Smart Digital Controller
- RUNNER MPPT Solar Smart Digital Controller
- Série GALAXY haute puissance
- Série extérieure de Mars
- Régulateur solaire MPPT série eSMART
- Régulateur solaire MPPT série MASTER
- Accessoires
- (Hors produit) Régulateur solaire MPPT série WISER
- (Hors production) Onduleur Série SP 350W-20000W
- (A été retiré)
- (Hors production) Onduleur série I-Panda SPC
- Certifications
-
- S\'abonner
-
Recevez des mises à jour par e-mail sur les nouveaux produits
- Nous contacter
-
Tel: + 86-755-23091101 & + 86-755-23091100
Fax: + 86-755-23091102
Information: info@ipandee.com
Adresse: Plancher 2, Bâtiment A2, Lilang Software Park, N ° 31, Bulan Road, Nanwan Street, District de Longgang, Shenzhen
Code postal de Chine: 518000 Contacter maintenant
- Suivez nous
-
-
Pourquoi la tension de démarrage de l'onduleur est-elle supérieure à la tension minimale?
Dans l'onduleur connecté au réseau photovoltaïque, un paramètre est étrange, à savoir la tension de démarrage d'entrée de l'onduleur. Cette te... -
Comment résoudre le problème de surtension de l'onduleur AC?
MaintenantPhotovoltaïqueLa production d'électricité sur réseau devient de plus en plus populaire et les maisons des particuliers peuvent voir les ... -
La différence entre une onde sinusoïdale améliorée et un onduleur à onde sinusoïdale pure
Cet article décrit la différence entre une onde sinusoïdale améliorée et un inverseur à onde sinusoïdale pure. ModifiedSine Pure Wave: Les ondu... -
Les dix plus grandes entreprises d'onduleurs photovoltaïques au monde
L'onduleur est également appelé régulateur de puissance et, selon son utilisation dans le système de production d'énergie photovoltaïque, il peu... -
Quelle est la différence entre la fonction MPPT et l’onduleur solaire sans fonction MPPT?
Le contrôleur MPPT utilise la technologie de suivi du point de puissance maximale pour extraire le maximum de puissance du panneau solaire afin de ch... -
Pourquoi l'onduleur devrait-il cesser de fonctionner lorsque le réseau est à court d'énergie
Certaines personnes installent un système photovoltaïque, elles ont l’esprit «même si le réseau électrique est coupé, s’il ya du soleil et qu... -
Première usine de recyclage de panneaux photovoltaïques en Europe
Les panneaux solaires ont une durée de vie de 20 à 30 ans. Parallèlement à la production de masse de l’industrie mondiale de fabrication d’éner... -
Les scientifiques ont découvert que le sable peut fabriquer des matériaux en silicium pour cellules
Selon un rapport de l'agence de presse Kyodo du 6 novembre, des professeurs invités de l'Université de Tokyo, Sugawara, et d'autres ont ouvert une ... -
Modèle de concurrence sur le marché du stockage d'énergie domestique
Le stockage de l'énergie, nouveau marché pour de nombreux fabricants de batteries en Chine etOnduleurLes vendeurs apportent l’opportunité de déve... -
Le Portugal atteindra 100% d'énergie renouvelable en 2050
Le ministre portugais de l'Environnement et de la Transformation de l'énergie, João Pedro Matos Fernandes, a révélé que le Portugal atteindrait s...
-
I-P-SPC Low Frequency Inverter with Built-in Solar Charge Controller 700W
- Application
- 1、Back-up UPS system for industrial, commercial, household,etc
- 2、Removable power and standby power for areas that are lack of utility.
- 3、Off-grid solar or wind power system
- 3.1、Off-grid solar or wind power system
- 3.2、AC first Off-grid solar or wind power system
- 3.3、DC first Off-grid solar or wind power system
Introduction
In DC/AC inversion mode, users can set this series of inverters to normal working mode or sleep mode. In utility mode, it has Auto Voltage Regulation (AVR) function, utility charging function (AC first model) and UPS function. This multifunctional low frequency pure sine wave inverter has the advantages of stable quality, strong load-carrying ability and long service life. It also can work in poor environment. It is the second generation of our low frequency pure sine wave inverter I-P-XD-series.
Features
1) Easy to install.To configure a solar system, users just need to connect it with solar panelsand batteries.
2)CPU management,Intelligentcontrol,modular design
3)LEDs LCD display.LCD can display various parameters(such as the output voltage, frequency,working mode)
4)Multifunctiondesign, AVR UPS function. Users don’t need to buy solar, controller, AC chargeror stabilizer.
5)External battery connection, it’s convenient for users to expand use time andback-up power time
6)With superload-carrying ability and high load capacity, this series of inverters can not only drive resistance load;but also various kinds of inductive loads such as motor, air conditioner,electric drills, fluorescent lamp, gas lamp. It can drive almost any kinds ofload
7)Low frequency puresine wave circuit design, stable quality, easy to maintenance, low failure rateand long service life (under proper operation,it can last at least 5 years)
8) Perfectprotection: low voltage protection, high voltage protection, over temperature protection,short-circuit protection, overload protection
9) CE / EMC / LVD/RoHS /FCC approvals
10) 2 years warranty,life-long technical support
Parameter
Mode |
1000VA |
||
Rated Output Capacity |
700W |
||
Peak Power |
1500W |
||
Battery Voltage(DC) |
24V |
||
PWM Solar Controller |
Voltage |
24V |
|
Current |
20A |
||
PV Max Input Voltage |
24V System:50V |
||
Size W×D×H(mm) |
335*165*375 |
||
Packing Size W×D×H(mm) |
355*185*395 |
||
Net Weight (kg) |
12 |
||
Gross Weight (kg) |
13 |
||
General Parameter |
|||
Working Mode (Setting) |
1 |
Utility first (AC first) battery standby mode |
|
2 |
Sleep Mode,no utility,load’s power is over 5% of rated output power, Inverter start to work automatically |
||
3 |
Battery first (DC first)utility standby mode |
||
AC Input |
Voltage |
220V±35% or 110V+35%(Optional) |
|
Frequency |
50Hz±3% or 60Hz±3% (Optional) |
||
AC Output |
Voltage |
220V±3% or 230V±3 or240V±3% or 100V±3% or 110V±3% (Optional) |
|
Frequency |
50Hz±0.5 or 60Hz±0.5 (Optional) |
||
Utility charge |
AC Charge Current |
0~15A |
|
Charge Time |
Depend on battery capacity and quantity |
||
Battery Protection |
Automatic detection, Charge and discharge protection,Intelligent Management |
||
PV Charge |
Total Current of PV Input Should Be Less Than Rated Current of PWM solar controller |
||
Display |
Display Mode |
LCD+LED |
|
Display Information |
Input voltage,output voltage,output frequency,battery capacity,Load condition,Status Information |
||
Output Wave Type |
Pure sine wave output,Total Harmonic Distortion THD≤3 |
||
Overload Ability |
>120% 1 min,>130% 10s |