- Bladeren door rubrieken
- EMMPT48 series MPPT solar charge controller
- The Explorer-NS series MPPT solar charge controlle
- MPPT solar charge controller eSmart4
- EXPLORER-M MPPT Solar Smart Digital Controller
- EXPLORER MPPT Solar Smart Digital Controller
- RUNNER MPPT Solar Smart Digital Controller
- GALAXY-serie met hoog vermogen
- Mars buiten-serie
- eSmart serie MPPT zonne-controller
- MASTER-serie MPPT-zonneregelaar
- Accessoires
- (Uit product) WISER serie MPPT zonnecontroller
- (Uit productie) Inverter SP Series 350W-20000W
- (Is verwijderd)
- (Uit productie) I-Panda SPC-serie omvormer
- Certificeringen
-
- Inschrijven
-
Ontvang e-mailupdates over nieuwe productenOntvang e-mailupdates over nieuwe producten
- Neem contact op
-
Tel: + 86-755-23091101 & + 86-755-23091100
Fax: + 86-755-23091102
Informatie: info@ipandee.com
Adres: Vloer 2, Gebouw A2, Lilang Software Park, No. 31, Bulay Road, Nanwan Street, Longgang District, Shenzhen
China Postcode: 518000 Contact nu
- Volg ons
-
-
Waarom is de startspanning van de omvormer hoger dan de minimumspanning?
In de fotovoltaïsche netgekoppelde omvormer is één parameter vreemd, dat wil zeggen de startspanning van de inverteringang. Deze spanning is hoger ... -
Hoe het overspanningsprobleem van de wisselstroomomvormer op te lossen?
nufotovoltaïscheOn-grid stroomopwekking wordt steeds populairder, en gewone mensen thuis kunnen PV-centrales in real time zien. Echter, voor de betro... -
Het verschil tussen een verbeterde sinusgolf en een zuivere sinusomvormer
Dit artikel beschrijft het verschil tussen een verbeterde sinusgolf en een zuivere sinusomvormer. ModifiedSine Pure Wave: de meest algemene omvormers ... -
Europa's eerste afvalafvalbedrijf voor fotovoltaïsche panelen
Zonnepanelen hebben een levensduur van 20 tot 30 jaar. Met een paar jaar geleden na het productieproces massaproductie wereldwijde zonne-energie, een ... -
'S Werelds top tien PV-omvormers
De omvormer wordt ook wel de vermogensregelaar genoemd.Aangezien van het gebruik van de omvormer in het fotovoltaïsche energieopwekkingssysteem, kan ... -
Waarom zou de omvormer niet meer werken als het stroomnet uitvalt?
Sommige mensen in de installatie van fotovoltaïsche systemen, zal een soort van hold "stroomstoring, zelfs als er zon is, hun huizen toegang tot elek... -
Wat is het verschil tussen MPPT-functie en zonne-omvormer zonder MPPT-functie?
De MPPT-controller maakt gebruik van de maximale technologie voor het volgen van vermogenspunten om het maximale vermogen uit de zonne-energiecollecti... -
Wetenschappers hebben ontdekt dat zand zonnecellen van silicium kan maken
Volgens de Japanse Kyodo News meldde op 6 november een visiting professor aan de Universiteit van Tokio karpervijver tonen Chendeng mensen open en de ... -
Binnenlandse energieopslag concurrentiepatroon
Energieopslag als een nieuwe markt voor veel batterijfabrikanten in China eninverterVerkopers bieden de mogelijkheid nieuwe zaken uit te breiden en de... -
Hoe een fotovoltaïsche krachtcentrale te bouwen
1. Wat voor soort dak is geschikt voor de installatie van Photovoltaic Power Plants? Het meest geschikt voor de installatie van binnenlandse fotovolta...
-
met lcd-scherm en ingebouwde MPPT solar laadregelaar omvormer, lage frequentie zuivere sinus omvormer
- gerelateerde uitgangsvermogen: 1000W, 1500W, 2000W, 3000W, 4000W, 5000W.
- piekvermogen: dubbel
- accuspanning: 12V / 24V / 48V (optioneel)
- uitgangsspanning: 220V ± 3% of 230V ± 3 of 240V ± 3% of 100V ± 3% of 110V ± 3% (optioneel)
- ingebouwde MPPT solar laadregelaar
- voltage: DC 12V / 24V / 48V auto-werk;
- stroom: 15A, 20A, 25A, 30A, 40A (optioneel);
- max.PV ingangsspanning: 100V;
- PV kosten efficiëntie: tot 99%;
- max.PV ingangsvermogen: 568W ~ 2272W.
Introduction
This series of product is a module design of inverter and built-in MPPT controller, which has the advantages of high conversion efficiency, low power consumption and strong load-carrying ability. With intelligent control, customers can set charging mode, (Utility as complementary power) AC first mode or DC first mode, timed inversion mode and timed utility mode, timed on/off sleep mode. This is the currently the most advanced inverter & controller hybrid in the world.
Application
1. Off-grid solar power system
2. Solar power system with utility as complementary power
Feature
1. Easy to install. To configure a solar system, customers only need to connect it with solar panels and batteries;
2. CPU management ,intelligent control,modular design, User-friendly LCD display;
3. Built-in MPPT controller, high charging efficiency ( 95%~99%);
4. Low power consumption, high conversion efficiency(85%~92%);
5. Intellectual,multi-function, convenient for customers with different using environment to fully use the solar energy;
6. External battery connection, convenient to expand back-up power time;
7. Strong load-carrying ability, low failure rate, easy maintenance and long service life (under proper operation, it may be as long as 5 years);
8. Perfect protection: low voltage protection, over voltage protection, overheat protection, short-circuit protection, overloads protection;
9. CE / EMC / LVD/ RoHS Approvals;
10. Two years warranty, life-long technical supports.
Function
1. Charging function
1.1 PV charge the battery, utility will not: when PV and utility are both connected to the machine, only the PV will charge the battery when there is sunlight
1.2 Both PV and utility will charge the battery: when PV and utility are both connected to the machine, AC (utility) will charge the battery. In the meanwhile, PV will also charge the battery if there is sunlight.
2. Utility as complementary power function
2.1 AC first , DC standby UPS mode
When both utility and battery are connected to the machine, utility will supply power to the loads prior to the battery. When utility is cut off, the battery will automatically continue to supply power.
2.2 DC first, AC standby UPS mode
When both utility and battery are connected to the inverter, battery will supply power to the loads prior to utility. When battery capacity is not enough, utility will continue to supply power automatically.
3. Timing function
3.1 Timed on/off normal working mode and sleep mode: can set specific time when to open normal output and when to close AC output to enter sleep mode.
3.2 Battery and utility switchable mode: can set specific time when to use battery or utility supply power (suitable for areas where electric fee is charged according to period in different intervals).
4. Recording/checking function
4.1 Machine fault checking: can check the machine fault information.
4.2 Discharge time checking: can check the discharge time of the battery.
Parameter
Parameter Model |
1000W |
1500W |
2000W |
3000W |
4000W |
5000W |
|||||||||||
Rated Output Power |
1000W |
1500W |
2000W |
3000W |
4000W |
5000W |
|||||||||||
Peak Power |
2000W |
3000W |
4000W |
6000W |
8000W |
10000W |
|||||||||||
Battery (Lead-acid battery) |
24V |
24V/48V(optional) |
48V |
||||||||||||||
Charging Parameter |
|||||||||||||||||
Charge Mode(setting) |
PV charge |
||||||||||||||||
PV charge + utility charge |
|||||||||||||||||
MPPT Solar Controller |
Voltage |
24V |
24V/48V |
48V |
|||||||||||||
Current |
20A |
25A |
30A |
40A |
40A |
40A |
|||||||||||
Max PV Input Voltage |
100V |
||||||||||||||||
PV Charge Efficiency |
95%~99% |
||||||||||||||||
Max PV Input Power |
568W |
24V: 710W |
24V: 852W |
24V:1136W |
2272W |
2272W |
|||||||||||
48V1420W |
48V: 1704W |
48V: 2272W |
|||||||||||||||
Utility |
AC Charge Current |
0~15A |
|||||||||||||||
Charge Mode |
3-Stage Charging |
||||||||||||||||
Inversion parameter |
|||||||||||||||||
AC Output |
Voltage |
220V±3% or 230V±3 or 240V±3% or 100V±3% |
|||||||||||||||
Frequency |
50Hz±0.5 or 60Hz±0.5 (optional) |
||||||||||||||||
Output wave type |
Pure sine wave output, waveform distortion rate≤3 |
||||||||||||||||
Overload ability |
>120% 1 min, >130% 10s |
||||||||||||||||
Power Consumption (under normal working mode) |
0.4A |
24V: 0.5A |
24V: 0.7A |
24V: 0.7A |
0.6A |
0.65A |
|||||||||||
48V: 0.4A |
48V: 0.45A |
48V: 0.5A |
|||||||||||||||
Power Consumption (under sleep mode) |
1-6W |
||||||||||||||||
Inverter Conversion Efficiency |
85%~92% |
||||||||||||||||
Utility Mode |
|||||||||||||||||
AC Input |
Voltage |
220V±35% or 110V+35%(optional) |
|||||||||||||||
Frequency |
The same as utility |
||||||||||||||||
AC Output |
Voltage |
220V±5% or 110V+5%(optional) |
|||||||||||||||
Frequency |
The same as utility |
||||||||||||||||
Overload Ability |
>120% 1 min,>130% 10s |
||||||||||||||||
(AC first or DC first) priority |
|||||||||||||||||
UPS Output(setting) |
AC first, DC standby |
||||||||||||||||
DC first, AC standby |
|||||||||||||||||
Switch Time |
<5ms (AC to DC / DC to AC) |
||||||||||||||||
Power On |
Set by users |
||||||||||||||||
Timed open / close AC output automatically |
|||||||||||||||||
General Parameter |
|||||||||||||||||
Display |
Display Mode |
LCD+LED |
|||||||||||||||
Display Information |
Input voltage, output voltage, output frequency, battery capacity, Load condition, Status Information |
||||||||||||||||
Protection |
Overload output, short-circuit, high-voltage input, low-voltage input, overheat |
||||||||||||||||
Environment
|
Temperature |
-10℃~50℃ |
|||||||||||||||
humidity |
10%~90% |
||||||||||||||||
Altitude |
≤4000m |
||||||||||||||||
Size W×D×H(mm) |
438*208*413 |
450*246*468 |
|||||||||||||||
Packing Size W×D×H(mm) |
520*310*460 |
540*300*518 |
|||||||||||||||
Net Weight (kg) |
15 |
17 |
19 |
25 |
34 |
35 |
|||||||||||
Gross Weight (kg) |
16 |
18 |
20 |
27 |
40 |
41 |
|||||||||||
Products photo
Company photo
Tel:+86 15002089033
Contactpersoon:Wenshen Huang
PDF-show:Pdf