- Navegue categorias
- EMMPT48 series MPPT solar charge controller
- The Explorer-NS series MPPT solar charge controlle
- MPPT solar charge controller eSmart4
- EXPLORER-M MPPT Solar Smart Digital Controller
- EXPLORER MPPT Solar Smart Digital Controller
- RUNNER MPPT Solar Smart Digital Controller
- Série de alta potência GALAXY
- Série ao ar livre de Marte
- controlador solar MPPT série eSMART
- Controlador solar MPPT série MASTER
- Acessórios
- (Fora do produto) Controlador solar MPPT
- (Fora de produção) Inversor SP Series 350W-20000W
- (Foi removido)
- (Fora de produção) Inversor I-Panda SPC Series
- Certificações.
-
- Se inscrever
-
Receba atualizações por e-mail sobre novos produtos
- Contate-Nos
-
Tel: + 86-755-23091101 e + 86-755-23091100
Fax: + 86-755-23091102
Informação: info@ipandee.com.
Endereço: Piso 2, Construindo A2, Lilang Software Park, No. 31, Bulan Road, Nanwan Street, Distrito de Longgang, Shenzhen
China Código Postal: 518000 Contate agora
- Siga-nos
-
-
Por que a tensão de partida do inversor é maior que a tensão mínima?
No inversor conectado à rede fotovoltaica, um parâmetro é estranho, isto é, a tensão de partida da entrada do inversor. Esta tensão é maior do ... -
Como resolver o problema de sobretensão do inversor de corrente alternada?
AgoraFotovoltaicaE geração de energia está se tornando cada vez mais popular, as pessoas comuns em casa pode ver em tempo real a figura da usina PV... -
A diferença entre uma onda senoidal melhorada e um inversor de onda senoidal pura
Este artigo descreve a diferença entre uma onda senoidal melhorada e um inversor de onda senoidal pura. ModifiedSine Pure Wave: Os inversores de uso ... -
As dez maiores empresas de inversores fotovoltaicos do mundo
O regulador de potência do inversor também conhecida, de acordo com o sistema inversor fotovoltaico uso pode ser dividido em rede elétrica de alime... -
Por que o inversor deve parar de funcionar quando a rede estiver sem energia?
Algumas pessoas na instalação de sistemas fotovoltaicos, vai realizar uma espécie de "queda de energia, mesmo se houver sol, suas casas também tê... -
Qual é a diferença entre a função MPPT e o inversor solar sem a função MPPT?
O controlador MPPT utiliza tecnologia de rastreamento de ponto de potência máxima para extrair a potência máxima do painel solar para carregar a b... -
A primeira usina de reciclagem de painéis fotovoltaicos de resíduos da Europa
Os painéis solares têm uma vida útil de 20 a 30 anos. Com alguns anos atrás, depois de a produção em massa de fabricação solar global, um núm... -
Os cientistas descobriram que a areia pode fazer materiais de silício de células solares
De acordo com a do Japão Kyodo News informou em 6 de novembro, um professor visitante no lago de carpas mostram Universidade de Tóquio Chendeng pess... -
Padrão de competição de mercado de armazenamento doméstico de energia
Armazenamento de energia como um novo mercado para muitos fabricantes de baterias na China eInversorOs fornecedores trazem a oportunidade de expandir ... -
Portugal vai conseguir 100% de fornecimento de energia renovável em 2050
Ministro português do Meio Ambiente e Energia transformação Jo? OPedroMatos Fernandes revelou que Portugal 2050 ser carbono neutra e objetiva, isto...
-
com display LCD e construído em MPPT controlador de carga solar de potência do inversor, de baixa frequência puro inversor de onda senoidal
- potência de saída relacionada: 1000W, 1500W, 2000W, 3000W, 4000W, 5000W.
- potência de pico: double
- tensão da bateria: 12V / 24V / 48V (opcional)
- tensão de saída: 220V ± 3% ou 230 ± 3 ou 240V ± 3% ou 100V ± 3% ou 110V ± 3% (opcional)
- built-in MPPT controlador de carga solar
- Tensão: DC 12V / 24V / 48V trabalho auto;
- atual: 15A, 20A, 25A, 30A, 40A (opcional);
- max.PV tensão de entrada: 100V;
- Eficiência da carga PV: até 99%;
- max.PV potência de entrada: 568W ~ 2272W.
Introduction
This series of product is a module design of inverter and built-in MPPT controller, which has the advantages of high conversion efficiency, low power consumption and strong load-carrying ability. With intelligent control, customers can set charging mode, (Utility as complementary power) AC first mode or DC first mode, timed inversion mode and timed utility mode, timed on/off sleep mode. This is the currently the most advanced inverter & controller hybrid in the world.
Application
1. Off-grid solar power system
2. Solar power system with utility as complementary power
Feature
1. Easy to install. To configure a solar system, customers only need to connect it with solar panels and batteries;
2. CPU management ,intelligent control,modular design, User-friendly LCD display;
3. Built-in MPPT controller, high charging efficiency ( 95%~99%);
4. Low power consumption, high conversion efficiency(85%~92%);
5. Intellectual,multi-function, convenient for customers with different using environment to fully use the solar energy;
6. External battery connection, convenient to expand back-up power time;
7. Strong load-carrying ability, low failure rate, easy maintenance and long service life (under proper operation, it may be as long as 5 years);
8. Perfect protection: low voltage protection, over voltage protection, overheat protection, short-circuit protection, overloads protection;
9. CE / EMC / LVD/ RoHS Approvals;
10. Two years warranty, life-long technical supports.
Function
1. Charging function
1.1 PV charge the battery, utility will not: when PV and utility are both connected to the machine, only the PV will charge the battery when there is sunlight
1.2 Both PV and utility will charge the battery: when PV and utility are both connected to the machine, AC (utility) will charge the battery. In the meanwhile, PV will also charge the battery if there is sunlight.
2. Utility as complementary power function
2.1 AC first , DC standby UPS mode
When both utility and battery are connected to the machine, utility will supply power to the loads prior to the battery. When utility is cut off, the battery will automatically continue to supply power.
2.2 DC first, AC standby UPS mode
When both utility and battery are connected to the inverter, battery will supply power to the loads prior to utility. When battery capacity is not enough, utility will continue to supply power automatically.
3. Timing function
3.1 Timed on/off normal working mode and sleep mode: can set specific time when to open normal output and when to close AC output to enter sleep mode.
3.2 Battery and utility switchable mode: can set specific time when to use battery or utility supply power (suitable for areas where electric fee is charged according to period in different intervals).
4. Recording/checking function
4.1 Machine fault checking: can check the machine fault information.
4.2 Discharge time checking: can check the discharge time of the battery.
Parameter
Parameter Model |
1000W |
1500W |
2000W |
3000W |
4000W |
5000W |
|||||||||||
Rated Output Power |
1000W |
1500W |
2000W |
3000W |
4000W |
5000W |
|||||||||||
Peak Power |
2000W |
3000W |
4000W |
6000W |
8000W |
10000W |
|||||||||||
Battery (Lead-acid battery) |
24V |
24V/48V(optional) |
48V |
||||||||||||||
Charging Parameter |
|||||||||||||||||
Charge Mode(setting) |
PV charge |
||||||||||||||||
PV charge + utility charge |
|||||||||||||||||
MPPT Solar Controller |
Voltage |
24V |
24V/48V |
48V |
|||||||||||||
Current |
20A |
25A |
30A |
40A |
40A |
40A |
|||||||||||
Max PV Input Voltage |
100V |
||||||||||||||||
PV Charge Efficiency |
95%~99% |
||||||||||||||||
Max PV Input Power |
568W |
24V: 710W |
24V: 852W |
24V:1136W |
2272W |
2272W |
|||||||||||
48V1420W |
48V: 1704W |
48V: 2272W |
|||||||||||||||
Utility |
AC Charge Current |
0~15A |
|||||||||||||||
Charge Mode |
3-Stage Charging |
||||||||||||||||
Inversion parameter |
|||||||||||||||||
AC Output |
Voltage |
220V±3% or 230V±3 or 240V±3% or 100V±3% |
|||||||||||||||
Frequency |
50Hz±0.5 or 60Hz±0.5 (optional) |
||||||||||||||||
Output wave type |
Pure sine wave output, waveform distortion rate≤3 |
||||||||||||||||
Overload ability |
>120% 1 min, >130% 10s |
||||||||||||||||
Power Consumption (under normal working mode) |
0.4A |
24V: 0.5A |
24V: 0.7A |
24V: 0.7A |
0.6A |
0.65A |
|||||||||||
48V: 0.4A |
48V: 0.45A |
48V: 0.5A |
|||||||||||||||
Power Consumption (under sleep mode) |
1-6W |
||||||||||||||||
Inverter Conversion Efficiency |
85%~92% |
||||||||||||||||
Utility Mode |
|||||||||||||||||
AC Input |
Voltage |
220V±35% or 110V+35%(optional) |
|||||||||||||||
Frequency |
The same as utility |
||||||||||||||||
AC Output |
Voltage |
220V±5% or 110V+5%(optional) |
|||||||||||||||
Frequency |
The same as utility |
||||||||||||||||
Overload Ability |
>120% 1 min,>130% 10s |
||||||||||||||||
(AC first or DC first) priority |
|||||||||||||||||
UPS Output(setting) |
AC first, DC standby |
||||||||||||||||
DC first, AC standby |
|||||||||||||||||
Switch Time |
<5ms (AC to DC / DC to AC) |
||||||||||||||||
Power On |
Set by users |
||||||||||||||||
Timed open / close AC output automatically |
|||||||||||||||||
General Parameter |
|||||||||||||||||
Display |
Display Mode |
LCD+LED |
|||||||||||||||
Display Information |
Input voltage, output voltage, output frequency, battery capacity, Load condition, Status Information |
||||||||||||||||
Protection |
Overload output, short-circuit, high-voltage input, low-voltage input, overheat |
||||||||||||||||
Environment
|
Temperature |
-10℃~50℃ |
|||||||||||||||
humidity |
10%~90% |
||||||||||||||||
Altitude |
≤4000m |
||||||||||||||||
Size W×D×H(mm) |
438*208*413 |
450*246*468 |
|||||||||||||||
Packing Size W×D×H(mm) |
520*310*460 |
540*300*518 |
|||||||||||||||
Net Weight (kg) |
15 |
17 |
19 |
25 |
34 |
35 |
|||||||||||
Gross Weight (kg) |
16 |
18 |
20 |
27 |
40 |
41 |
|||||||||||