- Browse Categories
- EMMPT48 series MPPT solar charge controller
- The Explorer-NS series MPPT solar charge controlle
- MPPT solar charge controller eSmart4
- EXPLORER-M MPPT Solar Smart Digital Controller
- EXPLORER MPPT Solar Smart Digital Controller
- RUNNER MPPT Solar Smart Digital Controller
- GALAXY high power series MPPT solar controller
- MARS outdoor series MPPT solar controller
- eSMART series MPPT solar controller
- MASTER series MPPT solar controller
- Accessories
- (out of product)WISER series MPPT solar controller
- (out of production)Inverter SP Series 350W-20000W
- (Has been removed)
- (out of production)I-Panda SPC Series Inverter
- Certifications
-
- Subscribe
-
Get email updates on new products
- Hot Products
- Contact Us
-
Tel: + 86-755-23091101&+86-755-23091100
Fax: + 86-755-23091102
Information: info@ipandee.com
address: Floor 2, building A2, LiLang Software Park, No. 31, Bulan Road, Nanwan street, Longgang District, Shenzhen
China Post code: 518000 Contact Now
- Follow us
- News
-
-
Why is the inverter starting voltage higher than the minimum voltage?
In the photovoltaic grid-connected inverter, one parameter is strange, that is, the inverter input starting voltage. This voltage is about 30V higher ... -
How to solve the AC inverter overvoltage problem?
just nowPhotovoltaicOn-grid power generation is becoming more and more popular, and ordinary people's homes can see PV power plants in real time. Howe... -
The difference between an improved sine wave and a pure sine wave inverter
This article describes the difference between an improved sine wave and a pure sine wave inverter. ModifiedSine Pure Wave: The most common general pur... -
Europe's first waste photovoltaic panel recycling plant
Solar panels have a service life of 20 to 30 years. Along with the mass production of the global solar energy manufacturing industry in the past few y... -
The world's top ten PV inverter companies
The inverter is also called the power regulator. According to the use of the inverter in the photovoltaic power generation system, it can be divided i... -
Why should the inverter stop working when the grid is out of power?
Some people install a photovoltaic system, they will have a mentality of "even if the power grid is cut off, if there is a sun, and their homes can us... -
What is the difference between MPPT function and solar inverter without MPPT function?
The MPPT controller utilizes maximum power point tracking technology to extract the maximum power from the solar array to charge the battery. The maxi... -
Scientists have discovered that sand can make solar cell silicon materials
According to a report by the Kyodo News Agency on November 6th, visiting professors of the University of Tokyo, Sugawara, and others opened a joint st... -
Domestic energy storage market competition pattern
Energy storage as a new market for many battery manufacturers in China andInverterVendors bring the opportunity to expand new affairs and change the p... -
How to build a photovoltaic power station
1. What kind of roof is suitable for the installation of photovoltaic power plants? The most suitable for the installation of domestic photovoltaic ro...
-
Maximum Power Point Tracking solar charge controller with OEM & ODM service and low price
- Model:smart1 12/24/48V/48V 40A-60A
- Efficiency: 95% upwards
- Maximum Current:40A-60A
- Rated Voltage:48V
- Max PV Input:150v
- Battery connection:all kinds
- Charge way:three stages
- Ambient Temp.Range:-25°C-+55°C
- Product Size:270*185*90mm
- Certificates:ISO9001,ISO0014,CE,RoHs,Fcc
- Service:OEM and ODM
Fuctions:
1)MPPT (Maximum Power Point Tracking) charge function
2)Auto Recognition function
3)3-stage charge function
4)Professional PC communication function
Feature:
1.MPPT charge mode,conversion efficiency upto 99%,can save 30%~60% of the power than traditional controller.
2.With high efficient MPPT operation scheme and adopting TI28035 chip,make the Solar panels utilization rate upto 99%.
Intelligent design,the device can be upgraded online,customers enjoy the lifelong upgrade service.
4.Compliance with the 2002/95/EC environment protecting demand,doesn’t include the Cadmium, hydride and fluoride
5.Adopting the well-known brand components,the devices can suffer the temperature not less than 105℃.The service life is designed to extend to 10 years in theory.
6.Charge mode: three stages (fast charge,constant charge,floating charge)
7.12V/24V/48V system auto recognize for easy control.
8.Nominal maximum solar input is DC 150V
9.Connected Battery Type choosing: Sealed lead acid, vented, Gel, NiCd battery. Other types of the batteries can also be defined.
10. LCD and LEDs show all kinds of parameter like products model, PV input voltage,battery voltage,charge current,charge power,work condition,and also can add customers’company name and website.
11. Communication Port.RS232 communication can provide communication protocol, This make the unified and integrated management more convenient to customers.
12. With providing a Microsoft by connecting with PC that can show the working state and all parameters in 7 languages.
13. Extensible LAN remote control.
14.Equipment integrity: controller+CD-ROM(microcomputer software) + communication wire+Anderson terminals;
15.CE,ROHS,FCC,PSE certifications approved.The device also can support to pass the other certifications.
16. 2 years warranty. And 3~10 years extended warranty service also can be provided.
Parameters
Model:I-P-MSC-DC12V/24V/48V-series |
40A |
50A |
60A |
||||
Charge Mode |
Maximum Power Point Tracking |
||||||
Method |
3 stages: fast charge(MPPT),constant voltage,floating charge |
||||||
System Type |
DC12V/24V/48V |
Automatic recognition |
|||||
System Voltage |
12V system |
DC9V~DC15V |
|||||
24V system |
DC18V~DC30V |
||||||
48Vsystem |
DC36V~DC60V |
||||||
Soft Start Time |
12V/24V/48Vsystem |
≤10S |
|||||
Dynamic Response Recovery Time |
12V/24V/48Vsystem |
500us |
|||||
Conversion Efficiency |
12V/24V/48Vsystem |
≥96.5%,≤99% |
|||||
PV Modules Utilization Rate |
12V/24V/48Vsystem |
≥99% |
|||||
Input Characteristics |
|||||||
MPPT Working Voltage and Range |
12V system |
DC18V~DC150V |
|||||
24V system |
DC34~DC150V |
||||||
48V system |
DC65~DC150V |
||||||
Low Voltage Input Protection Point |
12V system |
DC16V |
|||||
24V system |
DC30V |
||||||
48V system |
DC60V |
||||||
Low Voltage Input Recovery Point
|
12V system |
DC22V |
|||||
24V system |
DC34V |
||||||
48V system |
DC65V |
||||||
Max DC Voltage |
12V/24V/48V system |
DC160V |
|||||
Input Overvoltage Protection Point |
12V/24V/48V system |
DC150V |
|||||
Input Overvoltage Recovery Point |
12V/24V/48V system |
DC145V |
|||||
Max. PV Power |
12V system |
570W |
700W |
900W |
|||
24V system |
1130W |
1400W |
1700W |
||||
48V system |
2270W |
2800W |
3400W |
||||
Output Characteristics |
|||||||
Selectable Battery Types (Default type is GEL battery) |
12V/24V/48Vsystem |
Sealed lead acid, vented, Gel, NiCd battery |
|||||
Constant Voltage |
12V/24V/48V system |
Please check the charge voltage according to the battery type form. |
|||||
Floating Charge Voltage |
12V/24V/48V system |
||||||
Over Charge Protection Voltage |
12V system |
14.6V |
|||||
24V system |
29.2V |
||||||
48V system |
58.4V |
||||||
Rated Output Current |
12V/24V/48V system |
40A |
50A |
60A |
|||
Current-limiting Protection |
12V/24V/48V system |
44A |
55A |
66A |
|||
Temperature Factor |
12V/24V/48V system |
±0.02%/℃ |
|||||
Temperature Compensation |
12V/24V/48V system |
14.2V-(The highest temperature-25℃)*0.3 |
|||||
Output Ripples(peak) |
12V/24V/48V system |
200mV |
|||||
Output Voltage Stability Precision |
12V/24V/48V system |
≤±1.5% |
|||||
Display |
||
LCD display |
Input,output parameter and output power etc |
|
LED display |
3 LEDs indicates:Fault indicate light,charge indicate light,power source indicate light(check the LED instruction) |
|
Software Control through PC(communication port) |
RS232 (matching) or LAN(optional) |
|
Protection |
||
Input Low Voltage Protection |
Check the input characteristics |
|
Input Overvoltage Protection |
Check the input characteristics |
|
Input Polarity Reversal Protection |
yes |
|
Output Overvoltage Protection |
Check the output characteristics |
|
Output Polarity Reversal Protection |
yes |
|
Short-circuit Protection |
Recover after eliminating the Short-circuit fault,no problem for long term Short-circuit |
|
Temperature Protection |
95℃ |
|
Temperature protection |
Above 85℃,decrease the output power,decrease 3A per degree. |
|
Other Parameters |
||
Noise |
≤40dB |
|
Thermal methods |
Forced air cooling,fan speed rate regulated by temperature,when inner temperature is too low,fan ran slowly or stop;when controller stop working,fan also stop ran. |
|
Components |
World brand raw materials. Compliance with EU standards.All rated temperature of electrolytic capacitors not less than 105℃ |
|
Smell |
No peculiar smell and and toxic substances. |
|
Environment Protection |
Meet the 2002/95/EC,no cadmium hydride and fluoride |
|
Physical |
||
Measurement DxWxH(mm) |
270*185*90 |
|
N.G(kg) |
3 |
|
G.N(kg) |
3.6 |
|
Color |
Blue/Green (optional) |
|
Safety |
CE,RoHS, PSE,FCC |
|
EMC |
EN61000 |
|
Type of Mechanical Protection |
IP21 |
|
Environment |
||
Humidity |
0~90%RH ( no condense) |
|
Altitude |
0~3000m |
|
Operating Temperature |
-20℃ ~ +40℃ |
|
Storage Temperature |
-40℃ ~ +75℃ |
|
Atmospheric Pressure |
70~106kPa |
|
The specification is only for reference. Subject to change without prior notice.We provide OEM and ODM service.The 36V/72V/96V model also can be custom made for you.
Communication wayApplications
1. Industrial,commercial,household off-grid solar power system
2. moveable off-grid solar power system
3. Communication base stations
4. Energy knowledge popularization
Welcome to order I-Panda MPPT Solar Charge Controller Smart1 48V 60A
Tel:+86 15002089033
Contact Person:Wenshen Huang
PDF Show:PDF