- Browse Categories
- EMMPT48 series MPPT solar charge controller
- The Explorer-NS series MPPT solar charge controlle
- MPPT solar charge controller eSmart4
- EXPLORER-M MPPT Solar Smart Digital Controller
- EXPLORER MPPT Solar Smart Digital Controller
- RUNNER MPPT Solar Smart Digital Controller
- GALAXY high power series MPPT solar controller
- MARS outdoor series MPPT solar controller
- eSMART series MPPT solar controller
- MASTER series MPPT solar controller
- Accessories
- (out of product)WISER series MPPT solar controller
- (out of production)Inverter SP Series 350W-20000W
- (Has been removed)
- (out of production)I-Panda SPC Series Inverter
- Certifications
-
- Subscribe
-
Get email updates on new products
- Hot Products
- Contact Us
-
Tel: + 86-755-23091101&+86-755-23091100
Fax: + 86-755-23091102
Information: info@ipandee.com
address: Floor 2, building A2, LiLang Software Park, No. 31, Bulan Road, Nanwan street, Longgang District, Shenzhen
China Post code: 518000 Contact Now
- Follow us
- News
-
-
Why is the inverter starting voltage higher than the minimum voltage?
In the photovoltaic grid-connected inverter, one parameter is strange, that is, the inverter input starting voltage. This voltage is about 30V higher ... -
How to solve the AC inverter overvoltage problem?
just nowPhotovoltaicOn-grid power generation is becoming more and more popular, and ordinary people's homes can see PV power plants in real time. Howe... -
The difference between an improved sine wave and a pure sine wave inverter
This article describes the difference between an improved sine wave and a pure sine wave inverter. ModifiedSine Pure Wave: The most common general pur... -
Europe's first waste photovoltaic panel recycling plant
Solar panels have a service life of 20 to 30 years. Along with the mass production of the global solar energy manufacturing industry in the past few y... -
The world's top ten PV inverter companies
The inverter is also called the power regulator. According to the use of the inverter in the photovoltaic power generation system, it can be divided i... -
Why should the inverter stop working when the grid is out of power?
Some people install a photovoltaic system, they will have a mentality of "even if the power grid is cut off, if there is a sun, and their homes can us... -
What is the difference between MPPT function and solar inverter without MPPT function?
The MPPT controller utilizes maximum power point tracking technology to extract the maximum power from the solar array to charge the battery. The maxi... -
Scientists have discovered that sand can make solar cell silicon materials
According to a report by the Kyodo News Agency on November 6th, visiting professors of the University of Tokyo, Sugawara, and others opened a joint st... -
Domestic energy storage market competition pattern
Energy storage as a new market for many battery manufacturers in China andInverterVendors bring the opportunity to expand new affairs and change the p... -
How to build a photovoltaic power station
1. What kind of roof is suitable for the installation of photovoltaic power plants? The most suitable for the installation of domestic photovoltaic ro...
-
MPPT e-SMART Solar Charge Controller 12V 24V 48V 15A~40A
- Introduction: e-SMART MPPT (Maximum Power Point Tracking) Solar Charge Controller is a smart solar controller with automatic identification function, intelligent charge and discharge function, and three-level charging function to protect the battery. It is 30% to 60% more efficient than traditional PWM controllers. It supports a variety of batteries. It also features RS232 communication. The DC12V / 24V / 48V battery system is automatically recognized.
- feature:
1. MPPT charging mode, the peak efficiency is up to 99%, saving 30%~60% of the traditional PWM controller of solar panels.
2. The DC12V / 24V / 48V battery system is automatically recognized, so users can easily use it in different systems.
3. The MaximumPV input voltage is up to DC100V.
4. Three-level charging: fast charging (MPPT), constant voltage charging, floating charging, can protect the battery well.
5. Three discharges: about mode and off mode and PV voltage (solar) control mode.
6. Users can choose 4 commonly used standard batteries (sealed lead acid, Vented, Gel, NiCd). Other types of batteries can be defined by the user.
7. Digitaltube can display battery voltage and charging current. The software can display various parameters such as model number, PV input voltage, battery type, battery voltage, charging current, charging power, and working status.
8. RS232 communication, we can also provide communication protocols to facilitate user integration management.
9. This controller can be connected infinitely in parallel.
10. CE and RoHS certifications have been approved. We can help customers approve other certifications.
11. 2 year warranty; 3 to 10 years extended technical service.
- parameter:
MPPT solar controller mode: |
15A |
20A |
25A |
30A |
40A |
||
Charging mode |
MPPT (maximum power point tracking) |
||||||
Charging method |
Three phases: constant current (MPPT), constant voltage, floating charge |
||||||
System type |
DC12V / 24V / 48V |
auto recognition |
|||||
System voltage |
12V system |
DC9V~DC15V |
|||||
24V system |
DC18V~DC30V |
||||||
48V system |
DC36V~DC60V |
||||||
Soft start time |
12V / 24V / 48V system |
≤3S |
|||||
Dynamic response recovery time |
12V / 24V / 48V system |
500US |
|||||
MPPT efficiency |
12V / 24V / 48V system |
≥96.5%, ≤99% |
|||||
Input characteristics |
|||||||
MPPT operating voltage range |
12V system |
DC14V~DC100V |
|||||
24V system |
DC30~DC100V |
||||||
48V system |
DC60~DC100V |
||||||
Low input voltage Protection point |
12V system |
DC14V |
|||||
24V system |
DC30V |
||||||
48V system |
DC60V |
||||||
Low input voltage Recovery point |
12V system |
DC18V |
|||||
24V system |
DC34V |
||||||
48V system |
DC65V |
||||||
High input voltage protection point |
12V / 24V / 48V system |
DC110 |
|||||
High input voltage recovery point |
12V / 24V / 48V system |
DC100V |
|||||
Maximum photovoltaic power |
12V system (W) |
213 |
284 |
355 |
426 |
568 |
|
24V system (W) |
426 |
568 |
710 |
852 |
1136 |
||
48V system (W) |
852 |
1136 |
1420 |
1704 |
2272 |
||
Charge science |
|||||||
Optional battery type (default gel battery) |
12V / 24V / 48V system |
Sealed lead acid, Vented, Gel, NiCd battery (You can also define other types of batteries)) |
|||||
Constant pressure |
12V / 24V / 48V system |
Please confirm the charging voltage according to the battery type. |
|||||
Floating charge |
12V / 24V / 48V system |
||||||
Rated input current |
12V / 24V / 48V system |
15A |
20A |
25A |
30A |
40A |
|
Limiting protection |
12V / 24V / 48V system |
20A |
25A |
30A |
35A |
45A |
|
Temperature Coefficient |
12V / 24V / 48V system |
±0.02%/°C |
|||||
Temperature compensation |
12V / 24V / 48V system |
14.2V- (maximum temperature -25 ° C) * 0.3 |
|||||
Output ripple (peak) |
12V / 24V / 48V system |
200mV |
|||||
Output voltage stability accurate |
12V / 24V / 48V system |
≤±1.5% |
|||||
Output discharge characteristics |
|||||||
The output voltage |
Battery based voltage |
||||||
Low voltage output Protection point |
The default is 10.5V; restore 11V; it can be adjusted. |
||||||
Rated output current |
30A |
||||||
Output control |
On mode, off mode, PV voltage control mode |
||||||
Output control setting mode |
Controller button or PC software |
||||||
display |
|||||||
LED digital tube display |
Battery voltage, charging current |
||||||
LED light display |
Charging indicator |
||||||
PC (communication port) |
RS232 |
||||||
protection |
|||||||
Low input voltage protection |
Check input characteristics |
||||||
High input voltage protection |
Check input characteristics |
||||||
Overcharge protection |
Yes |
||||||
Low voltage discharge protection |
Yes |
||||||
High current protection |
Yes |
||||||
Temperature protection |
Yes |
||||||
Other parameters |
|||||||
noise |
≤40dB |
||||||
Heat dissipation method |
Cool yourself |
Fan cooling |
|||||
Component |
Imported materials comply with EU standards. |
||||||
prove |
CE \ FCC \ RoHS Directive |
||||||
physical |
|||||||
Measuring D x W x H(mm) |
205 * 168 * 60 |
||||||
Package size D x W x H(mm) |
265 * 196 * 110 |
||||||
N.G (KG) |
1.8 kg |
||||||
G.N (KG) |
2KG |
||||||
Mechanical protection |
IP25 |
||||||
surroundings |
|||||||
humidity |
Relative humidity 0~90% (no condensation) |
||||||
height |
0~3000 meters |
||||||
Operating temperature |
-20°C~+ 50°C |
||||||
Storage temperature |
-40°C~+ 75°C |
||||||
Air pressure |
70~106kPa |
Remarks:
This specification is for reference only. Subject to change without noticeWe offer OEM and ODM services. The 36V / 72V / 96V models are also available for you.
- Product packaging
number |
Quantity |
Included items |
1 |
1 item |
Controller color (blue or green is optional OEM ODM order is very popular) |
2 |
2 |
Hanger (for controllers hanging on the wall) |
3 |
Set of 4 |
screw |
4 |
1 item |
RJ45 to RS232 cable |
Fives |
1 item |
Battery temperature sensor line |
6 |
2 |
Fuse (DC output) |
7 |
1 item |
User guidance (manual) |
8 |
1 item |
CD |
- Controller PC upper layer software and test software:
1.1 The first picture shows the operating state (charge and discharge), PVV voltage, charging voltage, charging current, etc. of the solar controller. The user can select the type of battery and the DC load output control method.
1.2 We provide PC upper layer software. Test software is not included. (User's PC hassoftware development platform, if required, please apply)
2. Information display and parameter setting.
2.1 ENTER1 button: Press ENTER1 on the left to display 2 digital battery voltages (if charging, 2 digital charging voltages are displayed), for example, battery voltage or charging voltage is 13.5V, display 13, please see Figure 2.1; press ENTER1 a little bit For longer, the user can set the battery type.
2.2 ENTER2 button: Press ENTER2 to display 2 digital battery currents (if it is not charging, it will display 00. If the charging current is 22.5A, display 22, please refer to Figure 2.2); press ENTER2 button again to set DC load control (on mode, off mode, photovoltaic voltage control mode)
Please see the user manual for more details.
- Other detailed parameters
- Please refer to the design outline, technical documentation, user manuals, etc.
- The R&D department produced the second edition on May 5, 2014.
Tel:+86 15002089033
Contact Person:Wenshen Huang
PDF Show:PDF