- Browse Categories
- EXPLORER-M MPPT Solar Smart Digital Controller(15)
- EXPLORER MPPT Solar Smart Digital Controller(12)
- RUNNER MPPT Solar Smart Digital Controller(9)
- GALAXY high power series MPPT solar controller(12)
- MARS outdoor series MPPT solar controller(10)
- eSMART series MPPT solar controller(23)
- MASTER series MPPT solar controller(28)
- Accessories(3)
- (out of product)WISER series MPPT solar controller(13)
- (out of production)Inverter SP Series 350W-20000W(110)
- (out of production)I-Panda SPC Series Inverter(70)
- (out of production)suspension of sale product(516)
- Certifications
- Subscribe
-
Get email updates on new products
- Contact us
- Tel: + 86-755-23091101&+86-755-23091100
Fax: + 86-755-23091102
Information: info@ipandee.com
address: Floor 2, building A2, LiLang Software Park, No. 31, Bulan Road, Nanwan street, Longgang District, Shenzhen
China Post code: 518000Contact Now
- Share
Products
I-P-SPC Low Frequency Solar Power Inverter with Built-in Solar Charge Controller 15000W
- I-P-SPC inverter has high conversion efficiency, low power consumption, super load-carrying ability, large charging current etc. Users can set output priority (AC first or DC first) .
- Function
- Battery charge Ups AVR voltage regulator
- Strong overload ability
- Low frequency Design
- DC first /AC first
- Sleep Function
- Charge Function
- DC to AC Funiction
- UPS Function
- Output wave form:Pure sine wave
- Material:Metal
- Display:LCD and LED
- controller built-in: yes
- modul structure: Yes
I-P-SPC Series Low Frequency SolarPower Inverter with Built-in Solar Charge Controller 15000w
Component
1)Highquality low frequency pure sine wave inverter(with utility charge functionand UPS function)
2)Built-in PWMsolar power charge controller
Application
1)Off-grid solar power system
2) Utility and solar complementarypower generation system
Features
1) Easy toinstall. To configure a solar system, users just need to connect it with solarpanels and batteries.
2)CPUmanagement,Intelligent control,modular design
3)LEDs LCDdisplay. LCD can display various parameters(such as the output voltage, frequency,working mode)
4)Multifunctiondesign, AVR UPS function. Users don’t need to buy solar, controller, AC chargeror stabilizer.
5) External battery connection, it’sconvenient for users to expand use time and back-up power time
6)Withsuper load-carrying ability and high load capacity, this series of inverters can not only drive resistance load;but also various kinds of inductive loads such as motor, air conditioner,electric drills, fluorescent lamp, gas lamp. It can drive almost any kinds ofload
7)Lowfrequency pure sine wave circuit design, stable quality, easy to maintenance, lowfailure rate and long service life (underproper operation, it can last atleast 5 years)
8) Perfectprotection: low voltage protection, high voltage protection, over temperature protection,short-circuit protection, overload protection
9) CE /EMC / LVD/ RoHS /FCC approvals
10) 2years warranty, life-long technicalsupport
Function
Off-grid solarpower system
1. When connected withbattery and AC loads,users can set it to normal working mode or sleep mode.
1.1 Normal workingmode:FREQUENCY inthe LCD display is set to 01. No matterit’s connected AC loads or not, the inverter always convert DC to AC. It’s ready to supply power to the AC loads. Inthis mode, the LCD will display output voltage as bellow:
1.2 Sleep mode:FREQUNCYin the LCD display is set as 02.If the power of the connected AC loads is lowerthan 5% of the inverter’s rated power, there will be no output from theinverter. Only the chip of inverter is working. The power consumption of theinverter is only 1-6W. The LCD shows the output voltage 0. If the power of theconnected loads is over 5%,then the inverter will automatically convert DC toAC to supply power for the loads within 5s. The LCD shows the output voltage.As shown below:
Kindly note:
1) Only the solar panel charges thebattery
2) Off-grid solar power system. Itis suitable for areas that are lack of utility or plentiful solar
Utility andsolar complementary power generation system
2. UPSfunction When the inverter is connectedto battery and utility, users can set it to utility first (AC first) batterystandby mode or battery first (DC first)utility standby mode.
2.1.Utilityfirst (AC first) battery standby mode : FREQUENCY in the LCD display is set to 01.When utility and battery are connected to the inverter, utility will supplypower to the loads prior. When utility is cut off, the battery willautomatically continue to supply power via power inverter.
Stepsare as follows:
Step1: When utility is available, it will drive the loads directly after voltagebeing stabilized and at the same time charge batteries via power inverter .
Step2: When utility is cut off, the inverter will convert DC to AC automatically toensure uninterrupted power supply within 5ms.
Step3: When utility is available again, inverter will automatically transfer toutility supplying power to loads and charge batteries via power inverter at thesame time.
See Workflowas below.
LCDdisplayed as bellow:
Kindly note:
1) There are 2 ways to charge thebattery, utility and solar panel
2) This system is suitable for powersystems built in areas that are lack of utility. Or people can use solar andutility at the same time.
2.2. Batteryfirst (DC first)utility standy mode: FREQUENCY in the LCD display is set as 03. When utility andbattery are connected to the inverter, battery will supply power to the loadsprior to utility. When battery capacity is not enough, utility will continue tosupply power automatically.
Steps are as follows:
Step1: When battery is available, it will drive the AC loads via power inverter.
Step2: When battery does not have enough power, it will automatically transfer toutility supplying power to the loads
Step3: After the battery is fully charged (e.g. by solar or wind chargecontroller), it will automatically transfer to battery supplying power to theloads via power inverter.
See Workflowas below.
LCDdisplayed as bellow:
Kindlynote:
1)There is only one way to charge the battery: solar panel
2) This system is suitable for areas whereelectricity is expensive or environmental areas where solar power can be fullyused to save utility bill.such as home solar&wind system,streetlightsolar&wind system
Parameter
Mode |
20KVA |
||
Rated Output Capacity |
15KW |
||
Peak Power |
30KW |
||
Battery Voltage(DC) |
192V |
||
PWM Solar Controller |
Voltage |
192V |
|
Current |
50A |
||
PV Max Input Voltage |
400V |
||
Size W×D×H(mm) |
420*280*625 |
||
Packing Size W×D×H(mm) |
440*300*645 |
||
Net Weight (kg) |
105 |
||
Gross Weight (kg) |
115 |
||
General Parameter |
|||
Working Mode (Setting) |
1 |
Utility first (AC first) battery standby mode |
|
2 |
Sleep Mode,no utility,load’s power is over 5% of rated output power, Inverter start to work automatically |
||
3 |
Battery first (DC first)utility standby mode |
||
AC Input |
Voltage |
220V±35% or 110V+35%(Optional) |
|
Frequency |
50Hz±3% or 60Hz±3% (Optional) |
||
AC Output |
Voltage |
220V±3% or 230V±3 or240V±3% or 100V±3% or 110V±3% (Optional) |
|
Frequency |
50Hz±0.5 or 60Hz±0.5 (Optional) |
||
Utility charge |
AC Charge Current |
0~15A |
|
Charge Time |
Depend on battery capacity and quantity |
||
Battery Protection |
Automatic detection, Charge and discharge protection,Intelligent Management |
||
PV Charge |
Total Current of PV Input Should Be Less Than Rated Current of PWM solar controller |
||
Display |
Display Mode |
LCD+LED |
|
Display Information |
Input voltage,output voltage,output frequency,battery capacity,Load condition,Status Information |
||
Output Wave Type |
Pure sine wave output,Total Harmonic Distortion THD≤3 |
||
Overload Ability |
>120% 1 min,>130% 10s |
||
Power Consumption |
Sleep Mode |
1~6W |
|
Normal Mode |
1~3A |
||
Conversion Efficiency |
80%~90% |
||
Transfer Time |
<5ms (AC to DC / DC to AC) |
||
Protection |
Overload output,short-circuit,high-voltage input,low-voltage input,overheat |
||
Environment |
Temperature |
-10℃~50℃ |
|
Humidity |
10%~90% |
||
Altitude |
≤4000m |
Theabove is our standard parameter. Subject to change without prior notice.
Wehave our own professional inverter and controller R&D team and we provide technical support and OEM ODMservice
Thecontroller information above is our company’s standard parameter.It can bechanged to other PWM solar charge controller.
ConnectionDiagram
Others
Please see theoutline of the design,technical documents,user manuals,product brochures,etc.Research and development department made 1st edition on May 5, 2014..