- Browse Categories
- EMMPT48 series MPPT solar charge controller(1)
- The Explorer-NS series MPPT solar charge controlle(1)
- MPPT solar charge controller eSmart4(1)
- EXPLORER-M MPPT Solar Smart Digital Controller(15)
- EXPLORER MPPT Solar Smart Digital Controller(12)
- RUNNER MPPT Solar Smart Digital Controller(9)
- GALAXY high power series MPPT solar controller(12)
- MARS outdoor series MPPT solar controller(10)
- eSMART series MPPT solar controller(23)
- MASTER series MPPT solar controller(28)
- Accessories(3)
- (out of product)WISER series MPPT solar controller(12)
- (out of production)Inverter SP Series 350W-20000W(110)
- (out of production)I-Panda SPC Series Inverter(70)
- (Has been removed)(517)
- Certifications
- Subscribe
-
Get email updates on new products
- Contact us
- Tel: + 86-755-23091101&+86-755-23091100
Fax: + 86-755-23091102
Information: info@ipandee.com
address: Floor 2, building A2, LiLang Software Park, No. 31, Bulan Road, Nanwan street, Longgang District, Shenzhen
China Post code: 518000Contact Now
- Share
Products
I-P-SPC China factory DC AC Power Controller 350W~20000W
- Strong overload ability
- Low frequency Design
- DC first /AC first
- Sleep Function
- Charge Function
- DC to AC Funiction
- UPS Function
- Output wave form:Pure sine wave
- Material:Metal
- Display:LCD and LED
- controller built-in: yes
- modul structure: Yes
Features
1) Easy to install. Toconfigure a solar system, users just need to connect it with solar panels andbatteries.
2)CPU management,Intelligentcontrol,modular design
3)LEDs LCD display. LCDcan display various parameters(such as the output voltage, frequency, workingmode)
4)Multifunction design,AVR UPS function. Users don’t need to buy solar, controller, AC charger or stabilizer.
5)External battery connection, it’s convenient for users to expand use time andback-up power time
6)With superload-carrying ability and high load capacity, this series of inverters can not only drive resistance load;but also various kinds of inductive loads such as motor, air conditioner,electric drills, fluorescent lamp, gas lamp. It can drive almost any kinds ofload
7)Low frequency puresine wave circuit design, stable quality, easy to maintenance, low failure rateand long service life (under proper operation,it can last at least 5 years)
8) Perfect protection: lowvoltage protection, high voltage protection, over temperature protection, short-circuitprotection, overload protection
9) CE / EMC / LVD/ RoHS/FCC approvals
10) 2 years warranty, life-long technical support
Function
1. Sole inversion function under inversion mode(only connected to battery),can be set to normal working mode and sleep mode
1.1 Normal working mode:FREQUENCY in the LCD display is set as 01. No matter whether there are AC loads connected to the inverter or not, the inverter’s output terminal will always have voltage ready to supply power to the loads. Under this mode, the LCD will be displayed as bellow:
1.2 Sleep mode:FREQUNCY in the LCD display is set as 02.If thepower of the connected AC loads is lower than 5% of the inverter’s rated power,there will be no output from the inverter. Only the chip of inverter is working.The power consumption of the inverter is only 1-6W. The LCD shows the outputvoltage 0. If the power of the connected loads is over 5%,then the inverterwill automatically convert DC to AC to supply power for the loads within 5s.The LCD shows the output voltage. As shown below:
System introduction under this mode:
1) Only the solar panel charges the battery
2) Independent sole off-grid solar power system; suitable for areas that are lack of utility or have rich solar energy
2. UPS function When the inverter is connected to battery andutility, users can set it to utility first (AC first) battery standby mode orbattery first (DC first)utility standby mode.
2.1.Utilityfirst (AC first) battery standby mode : FREQUENCY in the LCD display is set to 01.When utility and battery are connected to the inverter, utility will supplypower to the loads prior. When utility is cut off, the battery willautomatically continue to supply power via power inverter.
Steps are as follows:
Step 1: When utility is available, it will drivethe loads directly after voltage being stabilized and at the same time chargebatteries via power inverter .
Step 2: When utility is cut off, theinverter will convert DC to AC automatically to ensure uninterrupted powersupply within 5ms.
Step 3: When utility is available again,inverter will automatically transfer to utility supplying power to loads andcharge batteries via power inverter at the same time.
See Workflow as below:

LCD displayed as bellow:
Kindly note:
1) There are 2 ways to charge thebattery, utility and solar panel
2) This system is suitable for powersystems built in areas that are lack of utility. Or people can use solar andutility at the same time.
2.2. Battery first(DC first)utility standy mode: FREQUENCY in the LCD display is set as 03. When utility andbattery are connected to the inverter, battery will supply power to the loadsprior to utility. When battery capacity is not enough, utility will continue tosupply power automatically.
Steps are as follows:
Step 1: When battery is available, it will drive the AC loadsvia power inverter.
Step 2: When battery does not have enough power, it willautomatically transfer to utility supplying power to the loads
Step 3: After the battery is fully charged (e.g. by solar orwind charge controller), it will automatically transfer to battery supplyingpower to the loads via power inverter.
See Workflow as below:
LCD displayed as bellow:
System introduction under this mode:
1) There is only way to charge the battery: solar panel
2) This system is suitable for areas where electricity is expensive and environmental areas where solar power can be fully used to save utiliypower, such as family solar&wind system and streetlight solar&wind system
Parameter
Model Parameter |
500VA |
700VA |
1000VA |
1500VA |
2000VA |
3000VA |
4000VA |
||||||||
Rated Output Power |
350W |
500W |
700W |
1000W |
1500W |
2000W |
3000W |
||||||||
Peak Power |
700W |
1000W |
1500W |
2000W |
3000W |
4000W |
6000W |
||||||||
Battery Voltage(DC)) |
12V or 24V |
24V |
24V or 48V |
||||||||||||
PWM Solar Controller |
Voltage |
12V or 24V |
24V |
24V or 48V |
|||||||||||
Current |
10A |
20A |
20A |
30A |
40A |
||||||||||
PV Max Input Voltage |
12V System:25V |
24V System:50V |
24V System:50V |
||||||||||||
Size W×D×H(mm) |
335*165*375 |
350*220*460 |
|||||||||||||
Packing Size W×D×H(mm) |
355*185*395 |
370*240*480 |
|||||||||||||
Net Weight (kg) |
7 |
8 |
12 |
14 |
20 |
23 |
29 |
||||||||
Gross Weight (kg) |
8 |
9 |
13 |
16 |
22 |
25 |
31 |
||||||||
|
|||||||||||||||
Model |
5000VA |
6000VA |
7000VA |
10kVA |
15kVA |
20kVA |
30kVA |
||||||||
Rated Output Power |
3500W |
4000W |
5000W |
7000W |
10000W |
15000W |
20000W |
||||||||
Peak Power |
7000W |
8000W |
10000W |
14000W |
20000W |
30000W |
40000W |
||||||||
Battery Voltage(DC) |
48V |
96V |
192V |
||||||||||||
PWM Solar Controller |
Voltage |
48V |
96V |
192V |
|||||||||||
Current |
50A |
60A |
50A |
50A |
|||||||||||
PV Max Input Voltage |
100V |
200V |
400V |
||||||||||||
Size W×D×H(mm) |
420*260*605 |
420*280*625 |
|||||||||||||
Packing Size W×D×H(mm) |
440*280*625 |
440*300*645 |
|||||||||||||
Net Weight (kg) |
31 |
50 |
50 |
55 |
85 |
105 |
125 |
||||||||
Gross Weight (kg) |
33 |
55 |
60 |
65 |
95 |
115 |
135 |
||||||||
General Parameter |
|||||||||||||||
|
01 |
Utility first (AC first) battery standby mode |
|||||||||||||
02 |
Sleep Mode,no utility,load’s power is over 5% of rated output power, Inverter start to work automatically |
||||||||||||||
03 |
Battery first (DC first)utility standby mode |
||||||||||||||
AC Input |
Voltage |
220V±35% or 110V+35%(Optional) |
|||||||||||||
Frequency |
50Hz±3% or 60Hz±3% (Optional) |
||||||||||||||
AC Output |
Voltage |
220V±3% or 230V±3 or240V±3% or 100V±3% |
|||||||||||||
Frequency |
50Hz±0.5 or 60Hz±0.5 (Optional) |
||||||||||||||
Utility charge |
AC Charge Current |
0~15A |
|||||||||||||
Charge Time |
Depend on battery capacity and quantity |
||||||||||||||
Battery Protection |
Automatic detection, Charge and discharge protection,Intelligent Management |
||||||||||||||
PV Charge |
Total Current of PV Input Should Be Less Than Rated Current of PWM solar controller |
||||||||||||||
Display |
Display Mode |
LCD+LED |
|||||||||||||
Display Information |
Input voltage,output voltage,output frequency,battery capacity,load condition,status Information |
||||||||||||||
Output Wave Type |
Pure sine wave output,Total Harmonic Distortion THD≤3 |
||||||||||||||
Overload Ability |
>120% 1 min,>130% 10s |
||||||||||||||
Power Consumption |
Sleep Mode |
1~6W |
|||||||||||||
Normal Mode |
1~3A |
||||||||||||||
Conversion Efficiency |
80%~90% |
||||||||||||||
Transfer Time |
<5ms (AC to DC / DC to AC) |
||||||||||||||
Protection |
Overload ,Short-circuit,High input voltage,Low input voltage,Overheat |
||||||||||||||
Environment |
Temperature |
-10℃~50℃ |
|||||||||||||
Humidity |
10%~90% |
||||||||||||||
Altitude |
≤4000m |
- The above parameters with “or” means that the parameter needs to do factory settings as per customer’s preference.
- We have our own professional inverter controller and UPS R&D team and we provide technical support and OEM service.
- The controller information above is our company’s standard parameter can be changed according to customer’s requirement.
Connection Diagram
Others
Please refer to the outline design, technical documents, product brochures, etc.
Made by Engineering Department, May 5, 2014, 1st Edition