- Browse Categories
- EMMPT48 series MPPT solar charge controller
- The Explorer-NS series MPPT solar charge controlle
- MPPT solar charge controller eSmart4
- EXPLORER-M MPPT Solar Smart Digital Controller
- EXPLORER MPPT Solar Smart Digital Controller
- RUNNER MPPT Solar Smart Digital Controller
- GALAXY high power series MPPT solar controller
- MARS outdoor series MPPT solar controller
- eSMART series MPPT solar controller
- MASTER series MPPT solar controller
- Accessories
- (out of product)WISER series MPPT solar controller
- (out of production)Inverter SP Series 350W-20000W
- (Has been removed)
- (out of production)I-Panda SPC Series Inverter
- Certifications
-
- Subscribe
-
Get email updates on new products
- Hot Products
- Contact Us
-
Tel: + 86-755-23091101&+86-755-23091100
Fax: + 86-755-23091102
Information: info@ipandee.com
address: Floor 2, building A2, LiLang Software Park, No. 31, Bulan Road, Nanwan street, Longgang District, Shenzhen
China Post code: 518000 Contact Now
- Follow us
- News
-
-
Why is the inverter starting voltage higher than the minimum voltage?
In the photovoltaic grid-connected inverter, one parameter is strange, that is, the inverter input starting voltage. This voltage is about 30V higher ... -
How to solve the AC inverter overvoltage problem?
just nowPhotovoltaicOn-grid power generation is becoming more and more popular, and ordinary people's homes can see PV power plants in real time. Howe... -
The difference between an improved sine wave and a pure sine wave inverter
This article describes the difference between an improved sine wave and a pure sine wave inverter. ModifiedSine Pure Wave: The most common general pur... -
Europe's first waste photovoltaic panel recycling plant
Solar panels have a service life of 20 to 30 years. Along with the mass production of the global solar energy manufacturing industry in the past few y... -
The world's top ten PV inverter companies
The inverter is also called the power regulator. According to the use of the inverter in the photovoltaic power generation system, it can be divided i... -
Why should the inverter stop working when the grid is out of power?
Some people install a photovoltaic system, they will have a mentality of "even if the power grid is cut off, if there is a sun, and their homes can us... -
What is the difference between MPPT function and solar inverter without MPPT function?
The MPPT controller utilizes maximum power point tracking technology to extract the maximum power from the solar array to charge the battery. The maxi... -
Scientists have discovered that sand can make solar cell silicon materials
According to a report by the Kyodo News Agency on November 6th, visiting professors of the University of Tokyo, Sugawara, and others opened a joint st... -
Domestic energy storage market competition pattern
Energy storage as a new market for many battery manufacturers in China andInverterVendors bring the opportunity to expand new affairs and change the p... -
How to build a photovoltaic power station
1. What kind of roof is suitable for the installation of photovoltaic power plants? The most suitable for the installation of domestic photovoltaic ro...
-
I-P-SP China manufacturer solar system 4000w
- Application
- 1、Back-up UPS system for industrial, commercial, household,etc
- 2、Removable power and standby power for areas that are lack of utility.
- 3、Off-grid solar or wind power system
- 3.1、Off-grid solar or wind power system
- 3.2、AC first Off-grid solar or wind power system
- 3.3、DC first Off-grid solar or wind power system
Introduction
In DC/AC inversion mode, users can set this series of inverters to normal working mode or sleep mode. In utility mode, it has Auto Voltage Regulation (AVR) function, utility charging function (AC first model) and UPS function. This multifunctional low frequency pure sine wave inverter has the advantages of stable quality, strong load-carrying ability and long service life. It also can work in poor environment. It is the second generation of our low frequency pure sine wave inverter I-P-XD-series.
Features
1、pure sine wave output, full power
2、CPU control,intelligent control,modular design
3、LCD display various parameters
4、Multifunction design (AVR, UPS), extra charger is not needed and electric appliances can be protected.
5、External battery connection, it’s convenient for users to expand use time and back-up power time
6、With super load carrying ability and high load capacity, this series of inverters can not only drive resistance load; but also various kinds of inductive loads, such as motor, air conditioner, electric drills, fluorescent lamp, gas lamp.
7、Low frequency circuit design, stable quality, low failure rate and long service life (under proper operation, it can last at least 5 years)
8、Perfect protection: low voltage protection, high voltage protection, over temperature protection, short-circuit protection, overload protection, alarm alert
9、CE / EMC / LVD/ RoHS Approvals
10、Two years warranty, life-long technical support
Function
1、DC to AC inversion function in inversion mode (only connected with batteries and loads) ,users can set it to normal working mode or sleep mode
1.1、Normal working mode:FREQUNCY in the LCD display is set to 01. No matter it’s connected AC loads or not, the inverter always convert DC to AC. It’s ready to supply power to the AC loads. In this mode, the LCD will display output voltage as bellow:
1.2、Sleep mode:FREQUNCY in the LCD display is set as 02.If the power of the connected AC loads is lower than 5% of the inverter’s rated power, there will be no output from the inverter. Only the chip of inverter is working. The power consumption of the inverter is only 1-6W. The LCD shows the output voltage 0. If the power of the connected loads is over 5%,then the inverter will automatically convert DC to AC to supply power for the loads within 5s. The LCD shows the output voltage. As shown below:
Load’s power<5% of inverter’s rated power Load’s power>5% of inverter’s rated power
2、UPS function When the inverter is connected to battery and utility, users can set it to utility first (AC first) battery standby mode or battery first (DC first)utility standy mode.
2.1、Utility first (AC first) battery standby mode : FREQUENCY in the LCD display is set to 01. When utility and battery are connected to the inverter, utility will supply power to the loads prior. When utility is cut off, the battery will automatically continue to supply power via power inverter.
Steps are as follows:
Step 1: When utility is available, it will drive the loads directly after voltage being stabilized and at the same time charge batteries via power inverter .
Step 2: When utility is cut off, the inverter will convert DC to AC automatically to ensure uninterrupted power supply within 5ms.
Step 3: When utility is available again, inverter will automatically transfer to utility supplying power to loads and charge batteries via power inverter at the same time.
See Workflow as below.
LCD displayed as bellow:
Utility supply power and charge battery Utility is unavailable, battery supply power
2.2、Battery first (DC first)utility standby UPS mode: FREQUENCY in the LCD display is set as 03. When utility and battery are connected to the inverter, battery will supply power to the loads prior to utility. When battery capacity is not enough, utility will continue to supply power automatically.
Steps are as follows:
Step 1: When battery is available, it will drive the AC loads via power inverter.
Step 2: When battery does not have enough power, it will automatically transfer to utility supplying power to the loads
Step 3: After the battery is fully charged (e.g. by solar or wind charge controller), it will automatically transfer to battery supplying power to the loads via power inverter.
See Workflow as below
LCD displayed as bellow:
Battery is available Battery is not available,utility supply power
Parameter
Model Parameter |
6000VA |
|
Rated Output Capacity |
4000W |
|
Peak Power |
8000W |
|
Battery Voltage(DC) |
48V/96V/192V(optional) |
|
Size W×D×H(mm) |
420*260*605 |
|
Packing Size W×D×H(mm) |
440*280*625 |
|
Net Weight (kg) |
50 |
|
Gross Weight (kg) |
55 |
|
General Parameter |
||
Working Mode |
1 |
Utility first (AC first) battery standby mode |
(Setting) |
2 |
Sleep Mode,no utility,load’s power higher than 5% of inverter rated output power,it will start to work automatically |
|
3 |
Battery first (DC first)utility standby UPS mode |
AC Input |
Voltage |
220V±35% or 110V+35%(optional) |
Frequency |
50Hz±3% or 60Hz±3% (optional) |
|
AC Output |
Voltage |
220V±3% or 230V±3 or 240V±3% or 100V±3% or 110V±3% (optional) |
Frequency |
50Hz±0.5 or 60Hz±0.5 (optional) |
|
Battery charge |
AC Charge Current |
0~15A |
Charge Time |
Depend on battery capacity and quantity |
|
Battery Protection |
Automatic detection, Charge and discharge protection,Intelligent Management |
|
Display |
Display Mode |
LCD |
Display Information |
Input voltage,output voltage,output frequency,battery capacity,Load condition,Status Information |
|
Output Wave Type |
Pure sine wave output,Total Harmonic Distortion THD≤3 |
|
Overload Ability |
>120% 1 min,>130% 10s |
|
Power Consumption |
Sleep Mode |
1~6W |
Normal Mode |
1~3A |
|
Conversion Efficiency |
80%~90% |
|
Transfer Time |
<5ms (AC to DC / DC to AC) |
|
Protection |
Overload ,Short-circuit,High input voltage,Low input voltage,Overheat |
|
Environment |
Temperature |
-10℃~50℃ |
Humidity |
10%~90% |
|
Altitude |
≤4000m |
We have our own professional inverter and controller R&D team and we
provide technical support and OEM ODM service.
Others
Please see the outline of the design,technical documents,user manuals,product brochures, etc.Research and development department made 2th edition on May 5, 2014.
Company
Tel:+86-15002089033
Contact Person:Henry Feng
PDF Show:PDF