- Browse Categories
- EMMPT48 series MPPT solar charge controller
- The Explorer-NS series MPPT solar charge controlle
- MPPT solar charge controller eSmart4
- EXPLORER-M MPPT Solar Smart Digital Controller
- EXPLORER MPPT Solar Smart Digital Controller
- RUNNER MPPT Solar Smart Digital Controller
- GALAXY high power series MPPT solar controller
- MARS outdoor series MPPT solar controller
- eSMART series MPPT solar controller
- MASTER series MPPT solar controller
- Accessories
- (out of product)WISER series MPPT solar controller
- (out of production)Inverter SP Series 350W-20000W
- (Has been removed)
- (out of production)I-Panda SPC Series Inverter
- Certifications
-
- Subscribe
-
Get email updates on new products
- Hot Products
- Contact Us
-
Tel: + 86-755-23091101&+86-755-23091100
Fax: + 86-755-23091102
Information: info@ipandee.com
address: Floor 2, building A2, LiLang Software Park, No. 31, Bulan Road, Nanwan street, Longgang District, Shenzhen
China Post code: 518000 Contact Now
- Follow us
- News
-
-
Why is the inverter starting voltage higher than the minimum voltage?
In the photovoltaic grid-connected inverter, one parameter is strange, that is, the inverter input starting voltage. This voltage is about 30V higher ... -
How to solve the AC inverter overvoltage problem?
just nowPhotovoltaicOn-grid power generation is becoming more and more popular, and ordinary people's homes can see PV power plants in real time. Howe... -
The difference between an improved sine wave and a pure sine wave inverter
This article describes the difference between an improved sine wave and a pure sine wave inverter. ModifiedSine Pure Wave: The most common general pur... -
Europe's first waste photovoltaic panel recycling plant
Solar panels have a service life of 20 to 30 years. Along with the mass production of the global solar energy manufacturing industry in the past few y... -
The world's top ten PV inverter companies
The inverter is also called the power regulator. According to the use of the inverter in the photovoltaic power generation system, it can be divided i... -
Why should the inverter stop working when the grid is out of power?
Some people install a photovoltaic system, they will have a mentality of "even if the power grid is cut off, if there is a sun, and their homes can us... -
What is the difference between MPPT function and solar inverter without MPPT function?
The MPPT controller utilizes maximum power point tracking technology to extract the maximum power from the solar array to charge the battery. The maxi... -
Scientists have discovered that sand can make solar cell silicon materials
According to a report by the Kyodo News Agency on November 6th, visiting professors of the University of Tokyo, Sugawara, and others opened a joint st... -
Domestic energy storage market competition pattern
Energy storage as a new market for many battery manufacturers in China andInverterVendors bring the opportunity to expand new affairs and change the p... -
How to build a photovoltaic power station
1. What kind of roof is suitable for the installation of photovoltaic power plants? The most suitable for the installation of domestic photovoltaic ro...
-
I-P- SMART1-DC12V/24V/48V/96V-30A Wide Range Input Voltage MPPT Solar Controller
- I-P- SMART1-DC12V/24V/48V/96V-30A MPPT Solar Controller. With MPPT, it can target the highest output possibe from PV panels, make efficiency higher upto 30%~60% than traditional PWM ones. It can store energy to different kinds of batteries(Gel,Vented, Sealed, NiCd). For all of our products has passed CE, ROHS, FCC etc.Unlimited connect in parallel.
2. 12v/24v/48v/96V system voltage automatic recognize.
3. Maximum input PV voltage upto DC300V.
4. 105degrees can be sufferred by good components.
5. Charge mode: three stages (fast charge, constant charge, floating charge)
6. Support kinds of batteries:Gel,Sealed lead acid,vented,NiCd,etc.
7. LCD and LEDs show parameters and system information,like PV input voltage,battery voltage,charge current,charge power,etc.
8. Port RS232 or connects to PC with upper software to show working state and parameters in 11 languages.
9. CE, RoHS, FCC certificatons approved.
10. 2 years warranty;3~10 years extended technical service.
Parameter
Model: I-P-SMART1-DC12V/24V/48V/96v series |
||||
Charge Mode |
Maximum Power Point Tracking |
|||
Method |
3 stages: fast charge(MPPT),constant voltage, floating charge |
|||
System Type |
DC12V/24V/48V |
Automatic recognition |
||
System Voltage |
12V system |
DC9V~DC15V |
||
24V system |
DC18V~DC30V |
|||
48Vsystem |
DC36V~DC60V |
|||
96Vsystem |
DC72V~DC120V |
|||
Soft Start Time |
12V/24V/48V/96v system |
≤10S |
||
Dynamic Response Recovery Time |
12V/24V/48V/96v system |
500us |
||
Conversion Efficiency |
12V/24V/48V/96v system |
≥96.5%,≤99% |
||
PV Modules Utilization Rate |
12V/24V/48V/96v system |
≥99% |
||
Input Characteristics |
||||
MPPT Working Voltage and Range |
12V system |
DC18V~DC150V |
||
24V system |
DC34~DC150V |
|||
48V system |
DC65~DC150V |
|||
96V system |
DC125~DC300V |
|||
Low Voltage Input Protection Point |
12V system |
DC16V |
||
24V system |
DC30V |
|||
48V system |
DC60V |
|||
96V system |
DC120V |
|||
Low Voltage Input Recovery Point
|
12V system |
DC22V |
||
24V system |
DC34V |
|||
48V system |
DC65V |
|||
96V system |
DC125V |
|||
Max DC Voltage |
12V/24V/48V system |
DC160V |
||
96V system |
DC300V |
|||
Input Overvoltage Protection Point |
12V/24V/48V system |
DC150 |
||
96V system |
DC300V |
|||
Input Overvoltage Recovery Point |
12V/24V/48V system |
DC145V |
||
96V system |
DC295V |
|||
Max. PV Power |
12V system |
450W |
||
24V system |
850W |
|||
48V system |
1700W |
|||
96V system |
3400W |
|||
Output Characteristics |
||||
Selectable Battery Types (Default type is GEL battery) |
12V/24V/48V/96Vsystem |
Sealed lead acid, vented, Gel, NiCd battery |
||
Constant Voltage |
12V/24V/48V/96V system |
Please check the charge voltage according to the battery type form. |
||
Floating Charge Voltage |
12V/24V/48V/96Vsystem |
|||
Over Charge Protection Voltage |
12V system |
14.6V |
||
24V system |
29.2V |
|||
48V system |
58.4V |
|||
96V system |
116.8V |
|||
Rated Output Current |
12V/24V/48V system |
30A |
||
Temperature Factor |
12V/24V/48V system |
±0.02%/℃ |
||
Temperature Compensation |
12V/24V/48V/96v system |
14.2V-(The highest temperature-25℃)*0.3 |
||
Output Ripples(peak) |
12V/24V/48V/96v system |
200mV |
||
Output Voltage Stability Precision |
12V/24V/48V/96v system |
≤±1.5% |
||
Display |
||||
LCD display |
Input, output parameter and output power etc |
|||
LED display |
3 LEDs indicates: Fault indicate light, charge indicate light, power source indicate light(check the LED instruction) |
|||
Software Control through PC(communication port) |
RS232 (matching) or LAN(optional) |
|||
Protection |
||||
Input Low Voltage Protection |
Check the input characteristics |
|||
Input Overvoltage Protection |
Check the input characteristics |
|||
Input Polarity Reversal Protection |
yes |
|||
Output Overvoltage Protection |
Check the output characteristics |
|||
Output Polarity Reversal Protection |
yes |
|||
Short-circuit Protection |
Recover after eliminating the Short-circuit fault, no problem for long term Short-circuit |
|||
Temperature Protection |
95℃ |
|||
Temperature protection |
Above 85℃,decrease the output power, decrease 3A per degree. |
|||
Other Parameters |
||||
Noise |
≤40dB |
|||
Thermal methods |
Forced air cooling, fan speed rate regulated by temperature, when inner temperature is too low, fan ran slowly or stop; when controller stop working, fan also stop ran. |
|||
Components |
World brand raw materials. Compliance with EU standards. All rated temperature of electrolytic capacitors not less than 105℃ |
|||
Smell |
No peculiar smell and toxic substances. |
|||
Environment Protection |
Meet the 2002/95/EC,no cadmium hydride and fluoride |
|||
Physical |
||||
Measurement DxWxH (mm) |
270*185*90 |
|||
N.G(kg) |
3 |
|||
G.N(kg) |
4.5 |
|||
Color |
Blue/Green (optional) |
|||
Safety |
CE, RoHS, PSE,FCC |
|||
EMC |
EN61000 |
|||
Type of Mechanical Protection |
IP21 |
|||
Environment |
||||
Humidity |
0~90%RH ( no condense) |
|||
Altitude |
0~3000m |
|||
Operating Temperature |
-20℃ ~ +40℃ |
|||
Storage Temperature |
-40℃ ~ +75℃ |
|||
Atmospheric Pressure |
70~106kPa |
Tel:+86-15002089033
Contact Person:Henry Feng
PDF Show:PDF