- Browse Categories
- EMMPT48 series MPPT solar charge controller(1)
- The Explorer-NS series MPPT solar charge controlle(1)
- MPPT solar charge controller eSmart4(1)
- EXPLORER-M MPPT Solar Smart Digital Controller(15)
- EXPLORER MPPT Solar Smart Digital Controller(12)
- RUNNER MPPT Solar Smart Digital Controller(9)
- GALAXY high power series MPPT solar controller(12)
- MARS outdoor series MPPT solar controller(10)
- eSMART series MPPT solar controller(23)
- MASTER series MPPT solar controller(28)
- Accessories(3)
- (out of product)WISER series MPPT solar controller(12)
- (out of production)Inverter SP Series 350W-20000W(110)
- (out of production)I-Panda SPC Series Inverter(70)
- (Has been removed)(517)
- (out of product)WISER series MPPT solar controller(1)
- High frequency pure sine wave inverter (stop)(9)
- TPI2 HPC (stop)(72)
- e-SMART Solar Controller (Stop)(109)
- First Generation MPPT Controller(stop)(71)
- Second Generation MPPT Controller(stop)(119)
- TPI2 Inverter (stop)(27)
- Certifications
- Subscribe
-
Get email updates on new products
- Contact us
- Tel: + 86-755-23091101&+86-755-23091100
Fax: + 86-755-23091102
Information: info@ipandee.com
address: Floor 2, building A2, LiLang Software Park, No. 31, Bulan Road, Nanwan street, Longgang District, Shenzhen
China Post code: 518000Contact Now
- Share
Products
China manufacturer providing intelligent AVR pure sine wave power inverter 24v 3000w & profressional OEM & ODM
- Place of Origin: Shenzhen China (Mainland)
- Brand Name: I-Panda
- Model Number: I-P-HPC-3000W
- Type: DC / AC Inverters
- Technology: CPU control
- Output Power: 3000w
- Output Type: Pure Sine Wave form
- DC Input Voltage: 24 / 48V
- AC Input Voltage: 100/110/220/230 / 240V
- Output Voltage: 100/110/220/230 / 240V
Pure sine wave inverter with built-in MPPT controller IP-HPC-Series is a module design. It has the advantages of high conversion efficiency, low power consumption and strong load-carrying ability. With intelligent control, users can set charging mode, ( Utility as complementary power) AC first mode or DC first mode, timing inversion mode and timing utility mode, on / off mode It is one of advanced hybrid inverter & amp;. controller in the world.

Application
1.Off-grid solar power system
2.Solar and utility complementary power system

Feature
1.Easy to install.To configure a solar system, users just need to connect it with solar panels and batteries
2.CPU management, intelligent control, modular design, LCD display
3.Built-in MPPT controller, high charging efficiency
4.Low power consumption, high conversion efficiency
5.Intellectual, multi-function, it's convenient for users to make full use of solar energy in different situation
6. External battery connection, it's convenient for users to expand back-up power time
7.Strong load-carrying ability, low failure rate, easy to maintenance and long service life (under proper operation, it can last at least 5 years)
8.Perfect protection: low voltage protection, high voltage protection, over temperature protection, short-circuit protection, overload protection
9.CE / EMC / LVD / RoHS Approvals
10.Two years warranty, life-long technical support
Function
1.Charging function
1.1 PV only mode: when PV and utility are both connected to the inverter, only the PV will charge the battery while utility will not charge the battery.
1.2 PV + AC hybrid mode: when PV and utility are both connected to the inverter, both PV and utility will charge the battery.

2.Utility as complementary power UPS function
2.1AC first, DC standby UPS mode
When utility and battery are connected to the inverter, utility will supply power to the loads preferentially. When utility is cut off, the battery will automatically continue to supply power to the loads.
Steps are as follows:
Step 1: When utility power is available, it will drive the loads directly after voltage being stabilized and charge batteries at the same time.
Step 2: When utility power is cut off suddenly, the inverter will convert DC to AC automatically to ensure uninterrupted power supply within 5ms.
Step 3: When utility power is available again, it will automatically transfer to utility supplying power to loads and charge batteries at the same time.
2.2DC first, AC standby UPS mode:
When utility and battery are connected to the inverter, battery will supply power to the loads prior to utility. When battery capacity is not enough, utility will continue to supply power automatically.
Steps are as follows:
Step 1: When battery has enough power, it will drive the loads directly via power inverter
Step 2: When battery does not have enough power, it will automatically transfer to utility supplying power to the loads
Step 3: After the battery is fully charged (eg by solar or wind charge controller), it will automatically transfer to battery supplying power to the loads.

3.Timing function
3.1 On / Off mode: Users can set specific time to turn on / off the output of the inverter.
3.2 Working mode: Battery or utility switchable mode Users can set specific time when to use battery or utility supplying power (suitable for areas where electric fee is charged differently in different period).

4.Recording / checking function
4.1 Inverter fault checking: Users can check the inverter fault information
4.2 Discharge time checking: Users can check the discharge time of the battery
Parameter
Parameter Model |
1000W |
1500W |
2000W |
3000W |
4000W |
5000W |
|||||||||||
Rated Output Power |
1000W |
1500W |
2000W |
3000W |
4000W |
5000W |
|||||||||||
Peak Power |
2000W |
3000W |
4000W |
6000W |
8000W |
10000W |
|||||||||||
Battery (Lead-acid battery) |
24V |
24V / 48V (optional) |
48V |
||||||||||||||
Charging Parameter |
|||||||||||||||||
Charge Mode (setting) |
PV charge |
||||||||||||||||
PV charge + utility charge |
|||||||||||||||||
MPPT Solar Controller |
Voltage |
24V |
24V / 48V |
48V |
|||||||||||||
Current |
20A |
25A |
30A |
40A |
40A |
40A |
|||||||||||
Max PV Input Voltage |
100V |
||||||||||||||||
PV Charge Efficiency |
95% to 99% |
||||||||||||||||
Max PV Input Power |
568W |
24V: 710W |
24V: 852W |
24V: 1136W |
2272W |
2272W |
|||||||||||
48V1420W |
48V: 1704W |
48V: 2272W |
|||||||||||||||
Utility |
AC Charge Current |
0 ~ 15A |
|||||||||||||||
Charge Mode |
3-Stage Charging |
||||||||||||||||
Inversion parameter |
|||||||||||||||||
AC Output |
Voltage |
220V ± 3%
or 230V ± 3 or 240V ± 3% or 100V ± 3% |
|||||||||||||||
Frequency |
50Hz ± 0.5 or 60Hz ± 0.5 (optional) |
||||||||||||||||
Output wave type |
Pure sine wave output, Total Harmonic Distortion THD≤3 |
||||||||||||||||
Overload ability |
& Gt; 120% 1 min, & gt; 130% 10s |
||||||||||||||||
Power Consumption (Under normal working mode) |
0.4A |
24V: 0.5A |
24V: 0.7A |
24V: 0.7A |
0.6A |
0.65A |
|||||||||||
48V: 0.4A |
48V: 0.45A |
48V: 0.5A |
|||||||||||||||
Power Consumption (Under sleep mode) |
1-6W |
||||||||||||||||
Inverter Conversion Efficiency |
85% to 92% |
||||||||||||||||
Utility Mode |
|||||||||||||||||
AC Input |
Voltage |
220V ± 35% or 110V + 35% (optional) |
|||||||||||||||
Frequency |
The same as utility's frequency |
||||||||||||||||
AC Output |
Voltage |
220V ± 5% or 110V + 5% (optional) |
|||||||||||||||
Frequency |
The same as utility's frequency |
||||||||||||||||
Overload Ability |
& Gt; 120% 1 min, & gt; 130% 10s |
||||||||||||||||
(AC first or DC first) priority |
|||||||||||||||||
UPS Output (setting) |
AC first, DC standby |
||||||||||||||||
DC first, AC standby |
|||||||||||||||||
Switch Time |
& Lt; 5ms (AC to DC / DC to AC) |
||||||||||||||||
Power
On |
Set by users |
||||||||||||||||
Timed on / off AC output automatically |
|||||||||||||||||
General Parameter |
|||||||||||||||||
Display |
Display Mode |
LCD + LED |
|||||||||||||||
Display Information |
Input voltage, output voltage, output frequency, battery capacity, load condition, status Information |
||||||||||||||||
Protection |
Overload, short-circuit, high-voltage input, low-voltage input, overheat |
||||||||||||||||
Environment
|
Temperature |
-10 ℃ ~ 50 ℃ |
|||||||||||||||
humidity |
10% to 90% |
||||||||||||||||
Altitude |
≤4000m |
||||||||||||||||
Size W × D × H (mm) |
438 * 208 * 413 |
450 * 246 * 468 |
|||||||||||||||
Packing Size W × D × H (mm) |
520 * 310 * 460 |
540 * 300 * 518 |
|||||||||||||||
Net Weight (kg) |
15 |
17 |
19 |
25 |
34 |
35 |
|||||||||||
Gross Weight (kg) |
16 |
18 |
20 |
27 |
40 |
41 |
Pictures

