- Browse Categories
- EMMPT48 series MPPT solar charge controller
- The Explorer-NS series MPPT solar charge controlle
- MPPT solar charge controller eSmart4
- EXPLORER-M MPPT Solar Smart Digital Controller
- EXPLORER MPPT Solar Smart Digital Controller
- RUNNER MPPT Solar Smart Digital Controller
- GALAXY high power series MPPT solar controller
- MARS outdoor series MPPT solar controller
- eSMART series MPPT solar controller
- MASTER series MPPT solar controller
- Accessories
- (out of product)WISER series MPPT solar controller
- (out of production)Inverter SP Series 350W-20000W
- (Has been removed)
- (out of production)I-Panda SPC Series Inverter
- Certifications
-
- Subscribe
-
Get email updates on new products
- Hot Products
- Contact Us
-
Tel: + 86-755-23091101&+86-755-23091100
Fax: + 86-755-23091102
Information: info@ipandee.com
address: Floor 2, building A2, LiLang Software Park, No. 31, Bulan Road, Nanwan street, Longgang District, Shenzhen
China Post code: 518000 Contact Now
- Follow us
- News
-
-
Why is the inverter starting voltage higher than the minimum voltage?
In the photovoltaic grid-connected inverter, one parameter is strange, that is, the inverter input starting voltage. This voltage is about 30V higher ... -
How to solve the AC inverter overvoltage problem?
just nowPhotovoltaicOn-grid power generation is becoming more and more popular, and ordinary people's homes can see PV power plants in real time. Howe... -
The difference between an improved sine wave and a pure sine wave inverter
This article describes the difference between an improved sine wave and a pure sine wave inverter. ModifiedSine Pure Wave: The most common general pur... -
Europe's first waste photovoltaic panel recycling plant
Solar panels have a service life of 20 to 30 years. Along with the mass production of the global solar energy manufacturing industry in the past few y... -
The world's top ten PV inverter companies
The inverter is also called the power regulator. According to the use of the inverter in the photovoltaic power generation system, it can be divided i... -
Why should the inverter stop working when the grid is out of power?
Some people install a photovoltaic system, they will have a mentality of "even if the power grid is cut off, if there is a sun, and their homes can us... -
What is the difference between MPPT function and solar inverter without MPPT function?
The MPPT controller utilizes maximum power point tracking technology to extract the maximum power from the solar array to charge the battery. The maxi... -
Scientists have discovered that sand can make solar cell silicon materials
According to a report by the Kyodo News Agency on November 6th, visiting professors of the University of Tokyo, Sugawara, and others opened a joint st... -
Domestic energy storage market competition pattern
Energy storage as a new market for many battery manufacturers in China andInverterVendors bring the opportunity to expand new affairs and change the p... -
How to build a photovoltaic power station
1. What kind of roof is suitable for the installation of photovoltaic power plants? The most suitable for the installation of domestic photovoltaic ro...
-
99% efficiency eSMART MPPT solar controller 40A
- Place of Origin China (Mainland)
- Brand Name I-Panda
- Model Number I-P-eSMART-40A
- Application MPPT Solar Charger Controller
- Rated Voltage 12V/24V/48V auto work
- Maximum Current 40A
- Max.battery voltage 60v
- Max.PV open circuit voltage 100VDC
- Communication RS232
- Rated load current 40A
- Max.PV input power 12V 568W,24V 1136W,48V 2272W
- Working temperature -20 ℃ ~ +50 ℃
This e-SMART MPPT (maximum Power Point Tracking) solar charge controller is a smart solar controller with automatic recognition function, smart charging and discharging function, three stages charging function to protect battery. It can increase 30%~60% efficiency than traditional PWM controller. It supports many kinds of batteries.It also have RS232 communication function.
1. MPPT charging mode, peak efficiency up to 99%, saving 30%~60% solar panel than traditional PWM controller.
2. DC12V/24V/48V battery system automatic recognition, users can use it in different system conveniently.
3. Maximum PV input voltage up to DC100V.
4. Three stages charge: fast charge(MPPT), constant voltage charge,floating charge, It can protect batteries well .
5. Three option of discharge: on mode and off mode and PV voltage(solar) control mode.
6. Users can choose 4 kinds of commonly standard batteries(Sealed lead acid, Vented, Gel, NiCd). Other kinds of batteries can be defined by users.
7. Digital tube can display battery voltage and charging current. The software can display various parameters such as model number, PV input voltage, battery type, battery voltage, charging current, charging power, working condition.
8. RS232 communication, we can offer communication protocol also, it’s convenient for user’s integration management.
9. This controller can be paralleled infinitely.
10. CE and RoHS Certifications are approved.We can help clients to approve other certifications.
11. 2 years warranty; 3~10 years extended technical service.
MPPT
solar controller modes: |
25A |
30A |
40A |
||
Charge mode |
MPPT(maximum power point tracking) |
||||
Charge method |
Three stages: constant current(MPPT),constant voltage,floating charge |
||||
System type |
DC12V/24V/48V |
Automatic recognition |
|||
System voltage |
12V system |
DC9V~DC15V |
|||
24V system |
DC18V~DC30V |
||||
48V system |
DC36V~DC60V |
||||
Soft start time |
12V/24V/48V system |
≤3S |
|||
Dynamic response recovery time |
12V/24V/48V system |
500us |
|||
MPPT efficiency |
12V/24V/48V system |
≥96.5%,≤99% |
|||
INPUT CHARACTERISTICS |
|||||
MPPT working voltage range |
12V system |
DC14V~DC100V |
|||
24V system |
DC30~DC100V |
||||
48V system |
DC60~DC100V |
||||
Low input voltage protection point |
12V system |
DC14V |
|||
24V system |
DC30V |
||||
48V system |
DC60V |
||||
Low input voltage Recovery point |
12V system |
DC18V |
|||
24V system |
DC34V |
||||
48V system |
DC65V |
||||
High input voltage protection point |
12V/24V/48V system |
DC110 |
|||
High input voltage recovery point |
12V/24V/48V system |
DC100V |
|||
Maximum PV power |
12V system (W) |
355 |
426 |
568 |
|
24V system (W) |
710 |
852 |
1136 |
||
48V system (W) |
1420 |
1704 |
2272 |
||
CHARGE CHRECTRESTICS |
|||||
Selectable Battery Types (Default Gel battery) |
12V/24V/48V system |
Sealed lead acid, Vented, Gel, NiCd battery (Other types of the batteries also can be defined)) |
|||
Constant Voltage |
12V/24V/48V system |
Please check the charge voltage according to the battery type form. |
|||
Floating Charge Voltage |
12V/24V/48V system |
||||
Rated Input Current |
12V/24V/48V system |
25A |
30A |
40A |
|
Current-limit Protection |
12V/24V/48V system |
30A |
35A |
45A |
|
Temperature Factor |
12V/24V/48V system |
±0.02%/℃ |
|||
Temperature Compensation |
12V/24V/48V system |
14.2V-(The highest temperature-25℃)*0.3 |
|||
Output Ripples(peak) |
12V/24V/48V system |
200mV |
|||
Output Voltage Stability Precision |
12V/24V/48V system |
≤±1.5% |
|||
Output Discharge Characteristics |
|||||
Output voltage |
Base on battery voltage |
||||
Low voltage output Protection point |
Default 10.5V; Recovery 11V; It can be adjustable. |
||||
Rated output Current |
30A |
||||
The output control |
On mode, Off mode, PV voltage control mode |
||||
Output control set mode |
Controller button or PC software |
||||
Display |
|||||
LED digital tube display |
Battery voltage, Charge current |
||||
LED light display |
Charging indicator light, LOAD indicator light |
||||
PC(communication port) |
RS232 |
||||
Protection |
|||||
Low input voltage protection |
Check the input characteristics |
||||
High input voltage protection |
Check the input characteristics |
||||
Charge overpower protection |
yes |
||||
Discharge low voltage protection |
yes |
||||
Discharge high current protection |
yes |
||||
Temperature protection |
yes |
||||
Other Parameters |
|||||
Noise |
≤40dB |
||||
Thermal heat-dissipating method |
Itself cooling |
Fan cooling |
|||
Components |
Imported material With EU standards. |
||||
Certification |
CE\FCC\RoHS |
||||
Physical |
|||||
Measurement D x W x H(mm) |
205*168*60 |
||||
package size D x W x H(mm) |
265*196*110 |
||||
N.G(KG) |
1.8kg |
||||
G.N(KG) |
2kg |
||||
Mechanical Protection |
IP25 |
||||
Environment |
|||||
Humidity |
0~90%RH ( no condense) |
||||
Altitude |
0~3000m |
||||
Operating Temperature |
-20℃ ~ +50℃ |
||||
Storage Temperature |
-40℃ ~ +75℃ |
||||
Atmospheric Pressure |
70~106kPa |
||||
Remarks:
The specification is only for reference. Subject to change without prior notice
We provide OEM and ODM service. The 36V/72V/96V model also can be customized for you.
Products Package:
Number |
quantity |
Items included |
1 |
1 pc |
Controller color (blue or green is optional OEM ODM order is highly welcome ) |
2 |
2 pc |
Hangers (used for controller hanging on the wall) |
3 |
4 set |
Screw |
4 |
1 pc |
RJ45 to RS232 cable |
5 |
1 pc |
Battery temperature sensor wire |
6 |
2 pc |
Fuse(DC output) |
7 |
1 pc |
User instruction(manual) |
8 |
1 pc |
CD |
1.2 We provide PC upper software. Testing software is not including. (user’s PC has software development platform, if needed, please apply for it)
2.2 ENTER2 button: press right ENTER2 show 2 digital battery current (if it is not charging, then it display 00, if the charge current is 22.5A, then it shows 22,please see Figure 2.2); press ENTER2 button a little bit longer, DC load control can be set (On mode, Off mode, PV voltage control mode)
Please see more details in the user manual.
Please see the outline of the design, technical documents, user manuals etc.
Research and development department made 2th version on May 5, 2014.
Tel:+86-15002089033
Contact Person:Henry Feng
PDF Show:PDF