- Browse Categories
- EMMPT48 series MPPT solar charge controller
- The Explorer-NS series MPPT solar charge controlle
- MPPT solar charge controller eSmart4
- EXPLORER-M MPPT Solar Smart Digital Controller
- EXPLORER MPPT Solar Smart Digital Controller
- RUNNER MPPT Solar Smart Digital Controller
- GALAXY high power series MPPT solar controller
- MARS outdoor series MPPT solar controller
- eSMART series MPPT solar controller
- MASTER series MPPT solar controller
- Accessories
- (out of product)WISER series MPPT solar controller
- (out of production)Inverter SP Series 350W-20000W
- (Has been removed)
- (out of production)I-Panda SPC Series Inverter
- Certifications
-
- Subscribe
-
Get email updates on new products
- Hot Products
- Contact Us
-
Tel: + 86-755-23091101&+86-755-23091100
Fax: + 86-755-23091102
Information: info@ipandee.com
address: Floor 2, building A2, LiLang Software Park, No. 31, Bulan Road, Nanwan street, Longgang District, Shenzhen
China Post code: 518000 Contact Now
- Follow us
- News
-
-
Why is the inverter starting voltage higher than the minimum voltage?
In the photovoltaic grid-connected inverter, one parameter is strange, that is, the inverter input starting voltage. This voltage is about 30V higher ... -
How to solve the AC inverter overvoltage problem?
just nowPhotovoltaicOn-grid power generation is becoming more and more popular, and ordinary people's homes can see PV power plants in real time. Howe... -
The difference between an improved sine wave and a pure sine wave inverter
This article describes the difference between an improved sine wave and a pure sine wave inverter. ModifiedSine Pure Wave: The most common general pur... -
Europe's first waste photovoltaic panel recycling plant
Solar panels have a service life of 20 to 30 years. Along with the mass production of the global solar energy manufacturing industry in the past few y... -
The world's top ten PV inverter companies
The inverter is also called the power regulator. According to the use of the inverter in the photovoltaic power generation system, it can be divided i... -
Why should the inverter stop working when the grid is out of power?
Some people install a photovoltaic system, they will have a mentality of "even if the power grid is cut off, if there is a sun, and their homes can us... -
What is the difference between MPPT function and solar inverter without MPPT function?
The MPPT controller utilizes maximum power point tracking technology to extract the maximum power from the solar array to charge the battery. The maxi... -
Scientists have discovered that sand can make solar cell silicon materials
According to a report by the Kyodo News Agency on November 6th, visiting professors of the University of Tokyo, Sugawara, and others opened a joint st... -
Domestic energy storage market competition pattern
Energy storage as a new market for many battery manufacturers in China andInverterVendors bring the opportunity to expand new affairs and change the p... -
How to build a photovoltaic power station
1. What kind of roof is suitable for the installation of photovoltaic power plants? The most suitable for the installation of domestic photovoltaic ro...
-
95%~99% mppt solar voltage tracker, 12v 24v 48v 30a solar charge controller
- 1.High conversion efficiency maximum 99%;
- 2.12v/24v/48v system auto recognition;
- 3.Support all kinds of battery;
- 4.Fast charge/Constant charge/Floating charge 3stage charge the batteries;
- 5.With DC output;
- 6.RS232 Communication port.
Introduction:
This is a MPPT (maximum Power Point Tracking) smart solar controller, with charging and discharging function, increasing 30%~60% efficiency than traditional PWM controller. It has automatic recognition function, three Stages charging function, also supports many kinds of battery charging and discharging, RS232 communication etc, It’s our company’s MPPT solar controller e-SMART series.
Remarks:DC12V/24V/48V battery system automatic recognised.
Features:
1. MPPT charging mode, peak efficiency up to 99%, saving 30%~60% solar panel than traditional PWM controller.
2. DC12V/24V/48V battery system automatic recognition, users would like to use in different system conveniently.
3. DC12V/24V/48V system, maximum PV input voltage up to DC100V.
4. Charge type: three stages charge fast charge(MPPT), constant voltage,
floating charge, protected our battery, lead to a long use age.
5. Discharge type owns always on pattern and always off pattern, it also has PV voltage solar controlling switch pattern.
6. Clients can auto choose any one in the 4 kinds of commonly used batteries, Sealed lead acid, vented, Gel, NiCd and custom other batteries.
7. Digital tube display controller battery voltage and charging current,upper computer display various parameters, such as model, PV input voltage, battery types, battery voltage, charging current, charging power, working condition etc.
8. RS232 communication, and that providing communication protocol, it’s convenient for customer’s integration management.
9. This controller could be paralleled infinitely.
10. CE, RoHS Certifications approved; cooperating with clients through the other certifications.
11. 2 years warranty; 3~10 years extended technical service.
Parameters:
MPPT
solar controller modes: |
30A |
||
Charge mode |
MPPT(maximum power point tracking) |
||
Charge method |
Three stages: constant current(MPPT),constant voltage,floating charge |
||
System type |
DC12V/24V/48V |
Automatic recognition |
|
System voltage |
12V system |
DC9V~DC15V |
|
24V system |
DC18V~DC30V |
||
48V system |
DC36V~DC60V |
||
Soft start time |
12V/24V/48V system |
≤3S |
|
Dynamic response recovery and range |
12V/24V/48V system |
500us |
|
MPPT efficiency |
12V/24V/48V system |
≥96.5%,≤99% |
|
INPUT CHARACTERISTICS |
|||
MPPT working voltage and Range |
12V system |
DC14V~DC100V |
|
24V system |
DC30~DC100V |
||
48V system |
DC60~DC100V |
||
Low voltage input Protection point |
12V system |
DC14V |
|
24V system |
DC30V |
||
48V system |
DC60V |
||
Low voltage input Recovery point |
12V system |
DC18V |
|
24V system |
DC34V |
||
48V system |
DC65V |
||
Input over voltage protection point |
12V/24V/48V system |
DC110V |
|
Input over voltage recovery point |
12V/24V/48V system |
DC100V |
|
Maximum PV power |
12V system (W) |
568 |
|
24V system (W) |
1136 |
||
48V system (W) |
2272 |
||
CHARGE CHRECTRESTICS |
|||
Selectable Battery Types (Default type is GEL battery) |
12V/24V/48V system |
Sealed lead acid, vented, Gel, NiCd battery (Other types of the batteries also can be defined)) |
|
Constant Voltage |
12V/24V/48V system |
Please check the charge voltage according to the battery type form. |
|
Floating Charge Voltage |
12V/24V/48V system |
Please check the charge voltage according to the battery type form. |
|
Rated Input Current |
12V/24V/48V system |
30A |
|
Current-limiting Protection |
12V/24V/48V system |
35A |
|
Temperature Factor |
12V/24V/48V system |
±0.02%/℃ |
|
Temperature Compensation |
12V/24V/48V system |
14.2V-(The highest temperature-25℃)*0.3 |
|
Output Ripples(peak) |
12V/24V/48V system |
200mV |
|
Output Voltage Stability Precision |
12V/24V/48V system |
≤±1.5% |
|
Output Discharge Characteristics |
|||
Output voltage |
Base on battery voltage |
||
Low voltage output Protection point |
Default 10.5V; recovery 11V; custom available ; |
||
Rated output Current |
30A |
||
The output control |
Always on, always off, PV voltage control switch |
||
Output control set mode |
Controller button or upper computer |
||
Display |
|||
LED digital tube display |
Battery voltage, charge current |
||
LED light display |
Charging indicator light, LOAD indicator light |
||
PC(communication port) |
RS232 |
||
Protection |
|||
Input Low Voltage Protection |
Check the input characteristics |
||
Input Overvoltage Protection |
Check the input characteristics |
||
Charge over voltage power Protection |
yes |
||
Low Voltage output Protection |
yes |
||
Rated output Current protection |
yes |
||
Temperature Protection |
yes |
||
Other Parameters |
|||
Noise |
≤40dB |
||
Thermal heat-dissipating method |
Itself cooling |
fan cooling |
|
Components |
Imported material, with EU standards. |
||
Certification |
CE\FCC\ROHS |
||
Physical |
|||
Measurement D x W x H(mm) |
205*168*60 |
||
package size D x W x H(mm) |
265*196*110 |
||
N.G(KG) |
1.8kg |
||
G.N(KG) |
2kg |
||
Type of Mechanical Protection |
IP25 |
||
Environment |
|||
Humidity |
0~90%RH ( no condense) |
||
Altitude |
0~3000m |
||
Operating Temperature |
-20℃ ~ +50℃ |
||
Storage Temperature |
-40℃ ~ +75℃ |
||
Atmospheric Pressure |
70~106kPa |
Remarks:
The specification is only for reference. Subject to change without prior notice
We provide OEM and ODM service. The 36V/72V/96V model also can be custom made for you.
Products Package:
Number |
quantity |
parets name |
1 |
1 pc |
Controller appearance(blue or green is optional,OEM is available also) |
2 |
2 pc |
hangers(Used in the controller hanging) |
3 |
4 set |
screw(Used for hanging ear lock in the controller) |
4 |
1 pc |
RS232 port |
5 |
1 pc |
Battery temperature sensing lines |
6 |
2 pc |
fuse(DC output) |
7 |
1 pc |
specification(manual) |
8 |
1 pc |
CD(Built-in upper software) |
1.Upper software and test software display information and set parameters.
1.1 show solar charge and discharge status, PV voltage, charge voltage, charge Current etc, and setting the type of the batteries, LOAD output control method.
1.2 Product standard upper software; testing software is not provided(Due to testing software need clients’ PC has software development platform, if clients have the requests, please apply to our company for taking)
Remarks: the PC software is offered freely by our company.
2. Information display and parameter setting
e-Smart series
2.1 ENTER1 button: press left ENTER1 show 2 digital battery voltage(if it is charging, then shows 2 digital charge voltage), for example,the battery voltage or charge voltage is 13.5V, it shows13.
Press ENTER1 for a long time, you can set battery types; more informations please see the specification.
2.2 ENTER2 button: press right ENTER2 show 2 digital battery current(if it has n’t been charging, then display 00, if the charge current is 20.5A, then it shows 25; press ENTER2, you can set always on and aways off pattern, you can see more details in the specification.
Other detailed parameters
Please see the outline of the design, technical documents, product manuals etc.
Engineering department custom 2th version on May 5, 2014.
Tel:+86 15002089033
Contact Person:Wenshen Huang
PDF Show:PDF