- Browse Categories
- EMMPT48 series MPPT solar charge controller
- The Explorer-NS series MPPT solar charge controlle
- MPPT solar charge controller eSmart4
- EXPLORER-M MPPT Solar Smart Digital Controller
- EXPLORER MPPT Solar Smart Digital Controller
- RUNNER MPPT Solar Smart Digital Controller
- GALAXY high power series MPPT solar controller
- MARS outdoor series MPPT solar controller
- eSMART series MPPT solar controller
- MASTER series MPPT solar controller
- Accessories
- (out of product)WISER series MPPT solar controller
- (out of production)Inverter SP Series 350W-20000W
- (Has been removed)
- (out of production)I-Panda SPC Series Inverter
- Certifications
-
- Subscribe
-
Get email updates on new products
- Hot Products
- Contact Us
-
Tel: + 86-755-23091101&+86-755-23091100
Fax: + 86-755-23091102
Information: info@ipandee.com
address: Floor 2, building A2, LiLang Software Park, No. 31, Bulan Road, Nanwan street, Longgang District, Shenzhen
China Post code: 518000 Contact Now
- Follow us
- News
-
-
Why is the inverter starting voltage higher than the minimum voltage?
In the photovoltaic grid-connected inverter, one parameter is strange, that is, the inverter input starting voltage. This voltage is about 30V higher ... -
How to solve the AC inverter overvoltage problem?
just nowPhotovoltaicOn-grid power generation is becoming more and more popular, and ordinary people's homes can see PV power plants in real time. Howe... -
The difference between an improved sine wave and a pure sine wave inverter
This article describes the difference between an improved sine wave and a pure sine wave inverter. ModifiedSine Pure Wave: The most common general pur... -
Europe's first waste photovoltaic panel recycling plant
Solar panels have a service life of 20 to 30 years. Along with the mass production of the global solar energy manufacturing industry in the past few y... -
The world's top ten PV inverter companies
The inverter is also called the power regulator. According to the use of the inverter in the photovoltaic power generation system, it can be divided i... -
Why should the inverter stop working when the grid is out of power?
Some people install a photovoltaic system, they will have a mentality of "even if the power grid is cut off, if there is a sun, and their homes can us... -
What is the difference between MPPT function and solar inverter without MPPT function?
The MPPT controller utilizes maximum power point tracking technology to extract the maximum power from the solar array to charge the battery. The maxi... -
Scientists have discovered that sand can make solar cell silicon materials
According to a report by the Kyodo News Agency on November 6th, visiting professors of the University of Tokyo, Sugawara, and others opened a joint st... -
Domestic energy storage market competition pattern
Energy storage as a new market for many battery manufacturers in China andInverterVendors bring the opportunity to expand new affairs and change the p... -
How to build a photovoltaic power station
1. What kind of roof is suitable for the installation of photovoltaic power plants? The most suitable for the installation of domestic photovoltaic ro...
-
3500w I-Panda SPC series controller and inverter hybird
- Component
- 1)High quality low frequency pure sine wave inverter(with utility charge
- function and UPS function)
- 2)Built-in PWM solar power charge controller
- Application
- 1)Off-grid solar power system
- 2)solar power system with utility power as a complementary
1) Easy to install. To configure a solar system, customers only need to connect it with solar panels and batteries.
2)CPU management and control,modular design
3)LCD display,can visually display various parameters(such as the output voltage, frequency, working mode, etc).
4)Multifunction design,customers don’t need to buy solar, controller, charger and stabilizer,etc.
5) External battery connection, convenient to expand back-up power time; user can connect as many batteries as needed according to the local sunlight and wind.
6)With super load-carrying ability and high load capacity, this series of inverters can not only drive resistance load; but also various kinds of inductive loads, such as motor, air conditioner, electric drills, fluorescent lamp, gas lamp, etc. It can drive almost any kinds of load.
7)Low frequency pure sine wave circuit design, good system stability, easy for maintenance, low failure rate and long service life (under proper operation, it may be as long as 5 years).
8) Perfect protection: low voltage protection, over voltage protection, overheat protection, short-circuit protection, overloads protection.
9) CE / EMC / LVD/ RoHS /CCC approvals.
10) 2 years warranty, life-long technical supports.
Function
1. Sole inversion function under inversion mode(only connected to battery, can be set to normal working mode and sleep mode
1.2 Sleep mode:FREQUENCY in the LCD display is set as 02. If the power of the loads that connected to the inverter is lower than 5% of the inverter’s rated power, there will be no output from the inverter. That is to say, only the chip of inverter is working under such condition and the power consumption is only 1-6W; If the power of the loads that connected to the inverter is higher than 5% of the inverter’s rated power, then the inverter will automatically start the inversion function and supply power to the loads within 5s. As shown below:
1) Only the solar panel charges the battery
2) Independent sole off-grid solar power system; suitable for areas that are lack of utility or have rich solar energy
Steps are as follows:
Step 1: When utility power is available, it will output directly after voltage being stabilized and charge batteries at the same time.
Step 2: When utility power is cut off suddenly, the inverter will convert DC power to AC power automatically to ensure uninterrupted power supply within 5ms.
Step 3: When utility power becomes available again, it will automatically transfer to utility supplying power to loads and charge batteries at the same time.
1) There are 2 ways to charge the battery, utility and solar panel
2) This system is suitable for power systems built in areas lacking utility or power systems that frequently used in areas with/without utility
Steps are as follows:
Step 1: When battery has enough power, it will supply power to the loads directly
Step 2: When battery does not have enough power, it will automatically transfer to utility supplying power to the loads
Step 3: After the battery is fully charged (e.g. by solar or wind charge controller), it will then automatically transfer to battery supplying power to the loads.
See Workflow as below.
1) There is only way to charge the battery: solar panel
2) This system is suitable for areas where electricity is expensive and environmental areas where solar power can be fully used to save utiliypower, such as family solar&wind system and streetlight solar&wind system
Mode |
5000VA |
||
Rated Output Capacity |
3500W |
||
Peak Power |
7000W |
||
Battery Voltage(DC) |
48V |
||
PWM Solar Controller |
Voltage |
48V |
|
Current |
50A |
||
PV Max Input Voltage |
100V |
||
Size W×D×H(mm) |
420*260*605 |
||
Packing Size W×D×H(mm) |
440*280*625 |
||
Net Weight (kg) |
31 |
||
Gross Weight (kg) |
33 |
||
General Parameter |
|||
Working Mode (Setting) |
1 |
Utility First, Battery Standby |
|
2 |
Sleep Mode,no utility,load’s power higher than 5% of rated power, start to work automatically |
||
3 |
Battery first, utility standby |
||
AC Input |
Voltage |
220V±35% or 110V+35%(Optional) |
|
Frequency |
50Hz±3% or 60Hz±3% (Optional) |
||
AC Output |
Voltage |
220V±3% or 230V±3 or240V±3% or 100V±3% or 110V±3% (Optional) |
|
Frequency |
50Hz±0.5 or 60Hz±0.5 (Optional) |
||
Utility charge |
AC Charge Current |
0~15A |
|
Charge Time |
Depend on battery capacity and quantity |
||
Battery Protection |
Automatic detection, Charge and discharge protection,Intelligent Management |
||
PV Charge |
Total Current of PV Input Should Be Less Than Rated Current |
||
Display |
Display Mode |
LCD+LED |
|
Display Information |
Input voltage,output voltage,output frequency,battery capacity,Load condition,Status Information |
||
Output Wave Type |
Pure sine wave output,waveform distortion rate≤3 |
||
Overload Ability |
>120% 1 min,>130% 10s |
||
Power Consumption |
Sleep Mode |
1~6W |
|
Normal Mode |
1~3A |
||
Conversion Efficiency |
80%~90% |
||
Transfer Time |
<5ms (AC to DC / DC to AC) |
||
Protection |
Overload output,short-circuit,high-voltage input,low-voltage input,overheat |
||
Environment |
Temperature |
-10℃~50℃ |
|
Humidity |
10%~90% |
||
Altitude |
≤4000m |
The controller information above is our company’s standard parameter and can be changed according to customer’s requirement.
We have our own professional inverter controller and UPS R&D team and we provide technical support and OEM service.
Connection Diagram
Please refer to the outline design, technical documents, product brochures, etc.
Made by Engineering Department, May 5, 2014, 1st Edition
Tel:+86-15002089033
Contact Person:Henry Feng
PDF Show:PDF