- Sfoglia le categorie
- EMMPT48 series MPPT solar charge controller
- The Explorer-NS series MPPT solar charge controlle
- MPPT solar charge controller eSmart4
- EXPLORER-M MPPT Solar Smart Digital Controller
- EXPLORER MPPT Solar Smart Digital Controller
- RUNNER MPPT Solar Smart Digital Controller
- GALAXY serie ad alta potenza
- Marte serie all'aperto
- regolatore solare MPPT serie eSmart
- Regolatore solare serie MPTER MASTER
- Accessori
- (Fuori prodotto) Regolatore solare MPPT
- (Fuori produzione) Inverter serie SP 350W-20000W
- (È stato rimosso)
- (Fuori produzione) Inverter serie I-Panda SPC
- Certificazioni
-
- sottoscrivi
-
Ricevi aggiornamenti via e-mail sui nuovi prodotti
- Contattaci
-
Tel: + 86-755-23091101 & + 86-755-23091100
Fax: + 86-755-23091102
Informazioni: info@ipandee.com.
Indirizzo: Floor 2, Building A2, Lilang Software Park, No. 31, Bullan Road, Nanwan Street, Distretto di Longgang, Shenzhen
CODICE CINALE: 518000 Contatta ora
- Seguici
-
-
Perché la tensione di avviamento dell'inverter è superiore alla tensione minima?
Nell'inverter collegato alla rete fotovoltaica, un parametro è strano, cioè la tensione di avviamento dell'ingresso dell'inverter. Questa tensione ... -
Come risolvere PV inverter AC problema sovratensioni?
orafotovoltaicoLa generazione di energia in rete sta diventando sempre più popolare e le case delle persone comuni possono vedere le centrali fotovol... -
La differenza tra un'onda sinusoidale migliorata e un inverter a onda sinusoidale pura
Questo articolo descrive la differenza tra un'onda sinusoidale migliorata e un inverter a onda sinusoidale pura. Onda pura modificata: Gli inverter pe... -
Le migliori dieci aziende di inverter fotovoltaici del mondo
Il regolatore di potenza dell'inverter noto anche, secondo il sistema inverter PV uso può essere suddivisa in rete di alimentazione indipendente e ut... -
Perché l'inverter dovrebbe smettere di funzionare quando la rete è scarica?
Alcune persone nella realizzazione di impianti fotovoltaici, si terrà una sorta di "interruzione di corrente, anche se c'è il sole, le loro case han... -
Qual è la differenza tra la funzione MPPT e l'inverter solare senza funzione MPPT?
Il controller MPPT utilizza la tecnologia di tracciamento del punto di massima potenza per estrarre la massima potenza dall'array solare per caricare ... -
Il primo impianto di riciclaggio di pannelli fotovoltaici per rifiuti in Europa
I pannelli solari hanno una durata di servizio da 20 a 30 anni. Con un paio di anni fa, dopo che la produzione di massa di produzione solare globale, ... -
Gli scienziati hanno scoperto che la sabbia può produrre materiali di silicio a celle solari
Secondo un rapporto dell'agenzia di stampa Kyodo, il 6 novembre, i visiting professor dell'Università di Tokyo, Sugawara, e altri hanno aperto uno st... -
Modello di concorrenza sul mercato del deposito di energia domestica
Stoccaggio di energia come nuovo mercato per molti produttori di batterie in Cina e in CinaInverterI venditori offrono l'opportunità di espandere nuo... -
Il Portogallo realizzerà il 100% di energia rinnovabile nel 2050
Ministro portoghese dell'Ambiente e dell'Energia trasformazione Jo? OPedroMatos Fernandes ha rivelato che il Portogallo 2050 è carbon neutral e ogget...
-
dc 24v ac 220v 1000w invertitore puro dell'onda di seno con built-in MPPT regolatore di carica solare
- potenza di uscita correlato: 1000W
- potenza di picco: doppio
- tensione della batteria: 12V / 24V / 48V (opzionale)
- Tensione di uscita: 220V ± 3% o 230V ± 3 o 240 V ± 3% o 100V ± 3% o 110V ± 3% (opzionale)
- built-in MPPT regolatore di carica solare
- tensione: DC 24V
- Corrente: 20A
- max.PV tensione in ingresso: 100V;
- Efficienza di carica PV: fino a 99%;
- max.PV potenza di ingresso: 568W.
Introduction
This series of product is a module design of inverter and built-in MPPT controller, which has the advantages of high conversion efficiency, low power consumption and strong load-carrying ability. With intelligent control, customers can set charging mode, (Utility as complementary power) AC first mode or DC first mode, timed inversion mode and timed utility mode, timed on/off sleep mode. This is the currently the most advanced inverter & controller hybrid in the world.
Application
- Off-grid solar power system
- Solar power system with utility as complementary power
Feature
- Easy to install. To configure a solar system, customers only need to connect it with solar panels and batteries
- CPU management ,intelligent control,modular design, User-friendly LCD display
- Built-in MPPT controller, high charging efficiency
- Low power consumption, high conversion efficiency
- Intellectual,multi-function, convenient for customers with different using environment to fully use the solar energy
- External battery connection, convenient to expand back-up power time
- Strong load-carrying ability, low failure rate, easy maintenance and long service life (under proper operation, it may be as long as 5 years)
- Perfect protection: low voltage protection, over voltage protection, overheat protection, short-circuit protection, overloads protection
- CE / EMC / LVD/ RoHS Approvals
- Two years warranty, life-long technical supports.
Function
1.Charging function
1.1 PV charge the battery, utility will not: when PV and utility are both connected to the machine, only the PV will charge the battery when there is sunlight
1.2 Both PV and utility will charge the battery: when PV and utility are both connected to the machine, AC (utility) will charge the battery. In the meanwhile, PV will also charge the battery if there is sunlight.
2.Utility as complementary power function
2.1 AC first , DC standby UPS mode
When both utility and battery are connected to the machine, utility will supply power to the loads prior to the battery. When utility is cut off, the battery will automatically continue to supply power.
2.2 DC first, AC standby UPS mode
When both utility and battery are connected to the inverter, battery will supply power to the loads prior to utility. When battery capacity is not enough, utility will continue to supply power automatically.
3.Timing function
3.1 Timed on/off normal working mode and sleep mode: can set specific time when to open normal output and when to close AC output to enter sleep mode.
3.2 Battery and utility switchable mode: can set specific time when to use battery or utility supply power (suitable for areas where electric fee is charged according to period in different intervals).
4.Recording/checking function
4.1 Machine fault checking: can check the machine fault information.
4.2 Discharge time checking: can check the discharge time of the battery.
Parameter
Parameter Model |
1000W |
|||
Rated Output Power |
1000W |
|||
Peak Power |
2000W |
|||
Battery (Lead-acid battery) |
24V |
|||
Charging Parameter |
||||
Charge Mode(setting) |
PV charge |
|||
PV charge + utility charge |
||||
MPPT Solar Controller |
Voltage |
24V |
||
Current |
20A |
|||
Max PV Input Voltage |
100V |
|||
PV Charge Efficiency |
95%~99% |
|||
Max PV Input Power |
568W |
|||
Utility |
AC Charge Current |
0~15A |
||
Charge Mode |
3-Stage Charging |
|||
Inversion parameter |
||||
AC Output |
Voltage |
220V±3% or
230V±3 or 240V±3% or 100V±3% |
||
Frequency |
50Hz±0.5 or 60Hz±0.5 (optional) |
|||
Output wave type |
Pure sine wave output, waveform distortion rate≤3 |
|||
Overload ability |
>120% 1 min, >130% 10s |
|||
Power Consumption (under normal working mode) |
0.4A |
|||
Power Consumption (under sleep mode) |
1-6W |
|||
Inverter Conversion Efficiency |
85%~92% |
|||
Utility Mode |
||||
AC Input |
Voltage |
220V±35% or 110V+35%(optional) |
||
Frequency |
The same as utility |
|||
AC Output |
Voltage |
220V±5% or 110V+5%(optional) |
||
Frequency |
The same as utility |
|||
Overload Ability |
>120% 1 min,>130% 10s |
|||
(AC first or DC first) priority |
||||
UPS Output(setting) |
AC first, DC standby |
|||
DC first, AC standby |
||||
Switch Time |
<5ms (AC to DC / DC to AC) |
|||
Power On |
Set by users |
|||
Timed open / close AC output automatically |
||||
General Parameter |
||||
Display |
Display Mode |
LCD+LED |
||
Display Information |
Input voltage, output voltage, output frequency, battery capacity, Load condition, Status Information |
|||
Protection |
Overload output, short-circuit, high-voltage input, low-voltage input, overheat |
|||
Environment |
Temperature |
-10℃~50℃ |
||
humidity |
10%~90% |
|||
Altitude |
≤4000m |
|||
Size W×D×H(mm) |
438*208*413 |
|||
Packing Size W×D×H(mm) |
520*310*460 |
|||
Net Weight (kg) |
15 |
|||
Gross Weight (kg) |
16 |
Products photos
Tel:+86 15002089033
Referente:wenshen huang
PDF Show.:PDF