- Parcourir les catégories
- EMMPT48 series MPPT solar charge controller
- The Explorer-NS series MPPT solar charge controlle
- MPPT solar charge controller eSmart4
- EXPLORER-M MPPT Solar Smart Digital Controller
- EXPLORER MPPT Solar Smart Digital Controller
- RUNNER MPPT Solar Smart Digital Controller
- Série GALAXY haute puissance
- Série extérieure de Mars
- Régulateur solaire MPPT série eSMART
- Régulateur solaire MPPT série MASTER
- Accessoires
- (Hors produit) Régulateur solaire MPPT série WISER
- (Hors production) Onduleur Série SP 350W-20000W
- (A été retiré)
- (Hors production) Onduleur série I-Panda SPC
- Certifications
-
- S\'abonner
-
Recevez des mises à jour par e-mail sur les nouveaux produits
- Nous contacter
-
Tel: + 86-755-23091101 & + 86-755-23091100
Fax: + 86-755-23091102
Information: info@ipandee.com
Adresse: Plancher 2, Bâtiment A2, Lilang Software Park, N ° 31, Bulan Road, Nanwan Street, District de Longgang, Shenzhen
Code postal de Chine: 518000 Contacter maintenant
- Suivez nous
-
-
Pourquoi la tension de démarrage de l'onduleur est-elle supérieure à la tension minimale?
Dans l'onduleur connecté au réseau photovoltaïque, un paramètre est étrange, à savoir la tension de démarrage d'entrée de l'onduleur. Cette te... -
Comment résoudre le problème de surtension de l'onduleur AC?
MaintenantPhotovoltaïqueLa production d'électricité sur réseau devient de plus en plus populaire et les maisons des particuliers peuvent voir les ... -
Les dix plus grandes entreprises d'onduleurs photovoltaïques au monde
L'onduleur est également appelé régulateur de puissance et, selon son utilisation dans le système de production d'énergie photovoltaïque, il peu... -
Pourquoi l'onduleur devrait-il cesser de fonctionner lorsque le réseau est à court d'énergie
Certaines personnes installent un système photovoltaïque, elles ont l’esprit «même si le réseau électrique est coupé, s’il ya du soleil et qu... -
Première usine de recyclage de panneaux photovoltaïques en Europe
Les panneaux solaires ont une durée de vie de 20 à 30 ans. Parallèlement à la production de masse de l’industrie mondiale de fabrication d’éner... -
Les scientifiques ont découvert que le sable peut fabriquer des matériaux en silicium pour cellules
Selon un rapport de l'agence de presse Kyodo du 6 novembre, des professeurs invités de l'Université de Tokyo, Sugawara, et d'autres ont ouvert une ... -
Le Portugal atteindra 100% d'énergie renouvelable en 2050
Le ministre portugais de l'Environnement et de la Transformation de l'énergie, João Pedro Matos Fernandes, a révélé que le Portugal atteindrait s... -
Modèle de concurrence sur le marché du stockage d'énergie domestique
Le stockage de l'énergie, nouveau marché pour de nombreux fabricants de batteries en Chine etOnduleurLes vendeurs apportent l’opportunité de déve... -
Les actions solaires sont affectées par le krach boursier américain
La bourse américaine en décembre n’est pas très bonne. Le marché boursier américain a connu des hauts et des bas, et les panneaux solaires ne so... -
Mise en service du projet de démonstration photothermique Delingha de 50 MW
En octobre dernier, le siège de Shenzhen de la Société nationale d’énergie nucléaire de Chine (CGN) a appris que la première centrale thermique...
-
qualité garantie régulateur de charge solaire mppt, régulateur de charge solaire 12v 24v 48v 15 a
- DC inpurt : travail d'auto 12V/24V/48V DC
- Max.charge actuel : 15 a
- Max.PV tension d'entrée: DC 100V
- Efficacité de conversion : Max.upto 99 %
- Mode de charge : trois stades de charge(MPPT) rapide, tension constante, flottant frais
- Port de communication RS 232
Introduction
This is a I-panda I-P-eSMART series MPPT (maximum Power Point Tracking) smart solar controller, with charging and discharging function, increasing 30%~60% efficiency than traditional PWM controller. It has automatic recognition function, three Stages charging function, also supports many kinds of battery charging and discharging, RS232 communication etc, It’s our company’s MPPT solar controller e-SMART series.
Features
1. MPPT charging mode, Max. efficiency up to 99%, saving 30%~60% solar panel than traditional PWM controller.
2. DC12V/24V/48V battery system automatic recognition, users would like to use in different system conveniently.
3. DC12V/24V/48V system, maximum PV input voltage up to DC100V.
4. Charge type: three stages charge fast charge(MPPT), constant voltage,
floating charge, protected our battery, lead to a long use age.
5. Discharge type owns always on pattern and always off pattern, it also has PV voltage solar controlling switch pattern.
6. Clients can auto select any one in the 4 kinds of commonly used batteries, Sealed lead acid, vented, Gel, NiCd and custom other batteries.
7. Digital tube display controller battery voltage and charging current,upper computer display various parameters, such as model, PV input voltage, battery types, battery voltage, charging current, charging power, working condition etc.
8. RS232 communication, and that providing communication protocol, it’s convenient for customer’s integration management.
9. This controller could be paralleled infinitely.
10. CE, RoHS Certifications approved; cooperating with clients through the other certifications.
11. 2 years warranty; 3~10 years extended technical service.
Products photos
Parameters
MPPT solar controller modes: |
15A |
||
Charge mode |
MPPT(maximum power point tracking) |
||
Charge method |
Three stages: constant current(MPPT),constant voltage,floating charge |
||
System type |
DC12V/24V/48V |
Automatic recognition |
|
System voltage |
12V system |
DC9V~DC15V |
|
24V system |
DC18V~DC30V |
||
48V system |
DC36V~DC60V |
||
Soft start time |
12V/24V/48V system |
≤3S |
|
Dynamic response recovery and range |
12V/24V/48V system |
500us |
|
MPPT efficiency |
12V/24V/48V system |
≥96.5%,≤99% |
|
INPUT CHARACTERISTICS |
|||
MPPT working voltage and Range |
12V system |
DC14V~DC100V |
|
24V system |
DC30~DC100V |
||
48V system |
DC60~DC100V |
||
Low voltage input Protection point |
12V system |
DC14V |
|
24V system |
DC30V |
||
48V system |
DC60V |
||
Low voltage input Recovery point |
12V system |
DC18V |
|
24V system |
DC34V |
||
48V system |
DC65V |
||
Input over voltage protection point |
12V/24V/48V system |
DC110V |
|
Input over voltage recovery point |
12V/24V/48V system |
DC100V |
|
Maximum PV power |
12V system (W) |
216 |
|
24V system (W) |
426 |
||
48V system (W) |
852 |
||
CHARGE CHRECTRESTICS |
|||
Selectable Battery Types (Default type is GEL battery) |
12V/24V/48V system |
Sealed lead acid, vented, Gel, NiCd battery (Other types of the batteries also can be defined)) |
|
Constant Voltage |
12V/24V/48V system |
Please check the charge voltage according to the battery type form. |
|
Floating Charge Voltage |
12V/24V/48V system |
Please check the charge voltage according to the battery type form. |
|
Rated Input Current |
12V/24V/48V system |
15A |
|
Current-limiting Protection |
12V/24V/48V system |
20A |
|
Temperature Factor |
12V/24V/48V system |
±0.02%/℃ |
|
Temperature Compensation |
12V/24V/48V system |
14.2V-(The highest temperature-25℃)*0.3 |
|
Output Ripples(peak) |
12V/24V/48V system |
200mV |
|
Output Voltage Stability Precision |
12V/24V/48V system |
≤±1.5% |
|
Output Discharge Characteristics |
|||
Output voltage |
Base on battery voltage |
||
Low voltage output Protection point |
Default 10.5V; recovery 11V; custom available ; |
||
Rated output Current |
30A |
||
The output control |
Always on, always off, PV voltage control switch |
||
Output control set mode |
Controller button or upper computer |
||
Display |
|||
LED digital tube display |
Battery voltage, charge current |
||
LED light display |
Charging indicator light, LOAD indicator light |
||
PC(communication port) |
RS232 |
||
Protection |
|||
Input Low Voltage Protection |
Check the input characteristics |
||
Input Overvoltage Protection |
Check the input characteristics |
||
Charge over voltage power Protection |
yes |
||
Low Voltage output Protection |
yes |
||
Rated output Current protection |
yes |
||
Temperature Protection |
yes |
||
Other Parameters |
|||
Noise |
≤40dB |
||
Thermal heat-dissipating method |
Itself cooling |
fan cooling |
|
Components |
Imported material, with EU standards. |
||
Certification |
CE\FCC\ROHS |
||
Physical |
|||
Measurement D x W x H(mm) |
205*168*60 |
||
package size D x W x H(mm) |
265*196*110 |
||
N.G(KG) |
1.8kg |
||
G.N(KG) |
2kg |
||
Type of Mechanical Protection |
IP25 |
||
Environment |
|||
Humidity |
0~90%RH ( no condense) |
||
Altitude |
0~3000m |
||
Operating Temperature |
-20℃ ~ +50℃ |
||
Storage Temperature |
-40℃ ~ +75℃ |
||
Atmospheric Pressure |
70~106kPa |





Tél:+86 15002089033
Personne de contact:Wenshen Huang
PDF Afficher:Pdf