Browse Categories
EMMPT48 series MPPT solar charge controller
The Explorer-NS series MPPT solar charge controlle
MPPT solar charge controller eSmart4
EXPLORER-M MPPT Solar Smart Digital Controller
EXPLORER MPPT Solar Smart Digital Controller
RUNNER MPPT Solar Smart Digital Controller
GALAXY high power series MPPT solar controller
MARS outdoor series MPPT solar controller
eSMART series MPPT solar controller
MASTER series MPPT solar controller
Accessories
(out of product)WISER series MPPT solar controller
(out of production)Inverter SP Series 350W-20000W
(Has been removed)
(out of production)I-Panda SPC Series Inverter
Certifications
Contact Us
Tel: + 86-755-23091101&+86-755-23091100  
Fax: + 86-755-23091102   
Information: info@ipandee.com
address: Floor 2, building A2, LiLang Software Park, No. 31, Bulan Road, Nanwan street, Longgang District, Shenzhen   
China Post code: 518000
Contact Now
Follow us
News
Your position: Home > Category > (Has been removed) > TPI2 HPC (stop) > I-P-TPI2 low frequency pure sine wave intelligent power inverter 4000w
I-P-TPI2 low frequency pure sine wave intelligent power inverter 4000wI-P-TPI2 low frequency pure sine wave intelligent power inverter 4000wI-P-TPI2 low frequency pure sine wave intelligent power inverter 4000wI-P-TPI2 low frequency pure sine wave intelligent power inverter 4000w

I-P-TPI2 low frequency pure sine wave intelligent power inverter 4000w

  • Brand Name:I-Panda
  • Model Number:I-P-TPI2-1000W-6000W
  • Output Power:1 - 200KW
  • Output Type:Single
  • Input Voltage:DC12V/ DC24V/DC48V
  • Output Voltage:100V/110V/220V/230V/240V AC(Optional)
  • Type:DC/AC Inverters
  • Output Frequency:50Hz or 60Hz
  • Conversion efficiency:87%-98%
  • Peak power:3 times of the rated output power
  • Function:DC to AC conversion, Battery charge,UPS
  • Working mode:AC first, DC first mode, Sleep mode
  • AC output frequency:50Hz or 60Hz (switchable)
  • Power consumption:1W - 6W
  • Display:LED+LCD
  • Warranty:2 years
  • Certificate:EMC,LVD,RoHS
Introduction 
I-P-TPI2-1000W-6000W is adopted the world's leading low-frequency inversion technical solutions. This series of inverter has the advantages of high conversion efficiency, low power consumption, super load-carrying ability, and large charging current. Users can set it to sleep mode and normal working mode according to the AC loads. Users also can set the output priority (AC first or DC first) and choose the output frequency 50Hz or 60Hz. It’s our second generation TPI series. 

Features 
1. Pure sine wave output 
2. CPU management, intelligent control,modular design 
3. LCD and LED display can show the parameters and inverter working status. 
4. Users can set it in sleep mode or normal working mode and set output priority (AC first or DC first). The output frequency (50Hz or 60Hz) can be chosen. 
5. High conversion efficiency (87%-98%), low power consumption (1W~6W under sleep mode). It is the best choice of inverters for solar power system 
6. The inverter can charge 8 kinds of batteries such as sealed lead acid battery, open lead-acid battery, gel battery. Kindly note: The lithium battery can be charged also, the related parameters need to be set in factory. 
7. High charging power and the charging function can be closed 
8. This series of inverters have strong load-carrying ability and overload capacity. The peak power is 3 times of the rated output power. For example, 1KW model can drive 1HP air conditioner, 2KW model can drive 2HP air conditioner, and 3KW can drive 3HP conditioner. 
9. Adopting the latest American low frequency circuit design, brand new imported electric materials, pure copper transformer, and the system is very stable long service life (more than 5 years under normal use) 
10. Perfect protection (low input voltage protection, high input voltage protection, over temperature protection, short-circuit protection, overload protection) 
11. EMC、LVD、RoHS certification approvals 
12. 2-year warranty and life-time technical assistance. 


Application 
1. Back-up UPS and EPS system for military, industrial, commercial, household,etc 
2. Removable standby power supply for areas that are lack of utility 
3. Off-grid solar or wind power system 
3.1. Off-grid solar or wind power system 
3.2. AC first Off-grid solar or wind power system 
3.3. DC first Off-grid solar or wind power system 

In the above application fields, this series of inverter is suitable for all kinds of inductive loads, capacitive load and resistive load such as TV, air conditioner, refrigerator and washing machine. 


Function 
1.DC/AC Conversion Function 
It can be set to normal working mode (on the panel turn the button  to “ON”) or sleep mode (on the panel turn the button to S-ON) 


1.1 Normal working mode (ON): No matter it’s connected AC loads or not the inverter always convert DC to AC. The LCD of the inverter displays the output voltage. The power consumption in normal working mode is a little higher than in sleep mode 
1.2 Sleep mode (S-ON):If the power of the connected AC loads is lower than 5% of the rated power of the inverter, there is  no output from the inverter. The LCD of it shows 0. Only the chip of inverter is working. The power consumption of the inverter is only 1-6W. If the power of the connected AC loads is more than 5%, then the inverter automatically convert DC to AC to supply power for the loads within 5s. The LCD of it displays no output. 

2. High-power intelligent charging function 
It Can charge 8 kinds of batteries (detail please check parameter) 
High charging power  (detail please check parameter) 
Three-stage charging mode: Constant current charging stage (CC), Constant voltage charging stage (CV), Float charging stage (CF) 

Note: When the battery type is set to “0”, it will not charge the battery and charging current is “0”. The charging indicator will not light. 

3. UPS function 
It can be set as utility first (AC first) battery standby mode or battery first(DC first) utility standby mode. 

3.1. Utility first battery standby UPS mode (on the panel turn the button to “AC”) 
When utility and battery are connected to the inverter, utility will supply power to the loads prior. When utility is cut off, the battery will automatically continue to supply power via power inverter. 
Steps are as below: 
Step 1: When utility is available, it will drive the loads directly and at the same time charge batteries.(battery type on the panel can not be 0) LCD will display AC output voltage.  
Step 2: When utility power is cut off, the inverter will convert DC power (battery) to AC power automatically to ensure uninterrupted power supply within 5ms. UPS function 
Step 3: When utility is available again, inverter will automatically transfer       to utility supplying power to loads. And utility will charge batteries via power inverter at the same time. 


3.2. Battery first utility standby UPS mode (on the panel turn the button to “DC”). 
 In this mode, users need to set “battery type” to “0”on the panel. Utility will not charge the battery. 
When utility and battery are connected to the inverter, battery will  
supply power to the loads prior. When battery capacity is not  
enough, utility will continue to supply power to the loads automatically. 
Steps are as follows: 

Step 1: When battery has enough power, it will supply power to the loads directly 
Step 2: When battery does not have enough power, inverter will automatically transfer to utility supplying power to the loads 
Step 3: After the battery is fully charged (e.g. by solar or wind charge controller), it will automatically transfer to battery supplying power to the loads via power inverter. 

Parameter 

Parameter    Model      

4000W

Rated Output Power

4000W

Peak Power

12000W

Battery Voltage(DC)

24V or 48V(optional)

Size W×D×H(mm)

440*218*400

Packing Size W×D×H(mm)

520*275*520

Net Weight (kg)

39

Gross Weight (kg) 

43

Working Mode

(Setting)

 

ON

Normal working mode

S-ON

Sleep Mode,1~6W consumption when load’s power higher than 5% rated output power, it will start to work automatically

OFF

Completely off

AC Input

Voltage

220V±35% or 110V+35%(optional)

Frequency

50HZ or 60HZ

AC Output

Voltage

220V±3% or 230V±3 or 240V±3% or 100V±3%
or 110V±3%(optional)

Frequency

Frequency is the same as under utility mode
Frequency 50Hz or 60Hz(optional)in DC/AC convert mode

Utility charging
(Battery type “0” means charging function is closed)

AC charge current
(MAX)

24V

48V

65A

35A

Battery type

American gel battery, Wool battery 1, Wool battery2, Sealed Lead Acid Battery, Europe gel battery, Open lead-acid batteries, Calcium Battery, De-Acid Battery or OEM Battery

Charging mode

Three-stage charging:CC, CV, CF

Charging time

Decided by battery capacity and quantity

Battery protection

Automatic detection,charge and discharge protection, intelligent management

UPS

priority

AC

Utility first, battery standby

DC

Battery first, utility standby

Display

Display Mode

LCD+LED

Display Information

Input voltage,output voltage,output frequency,battery capacity,Load condition,Status Information

Output Wave Type

Pure sine wave

Overload Ability

>120% 1 min,>130% 10s

Power Consumption

Sleep Mode

1~6W

Normal Mode

1~3A

Conversion Efficiency

87%~98%

Transfer Time

<5ms (AC to DC / DC to AC)

Protection

Overload output,short-circuit,high-voltage input,

low-voltage input,overheats

Environment

Temperature

-10℃~50℃

Humidity

 10%~90%

Altitude

≤4000m


The above is our standard parameter. Subject to change without prior notice. 

We have our own professional inverter and controller R&D team and we provide technical support and OEM ODM service. 


Other details 
Please Please see the outline of the design,technical documents,user manuals,product brochures, etc. 
Research and development department made 2th edition on May 13, 2014. 

Shenzhen ipandee New Energy Technology & Science Co., Ltd

Tel:+86 15002089033

Contact Person:Wenshen Huang

PDF Show:PDF

Send Inquiry
captcha
https://kefu5.cckefucloud.com/vclient/chat/?websiteid=p9rjd9g58z6e70x5e6vpx31vpm2kwyb4&wc=39157e7a&clerkid=906266