- Browse Categories
- EMMPT48 series MPPT solar charge controller
- The Explorer-NS series MPPT solar charge controlle
- MPPT solar charge controller eSmart4
- EXPLORER-M MPPT Solar Smart Digital Controller
- EXPLORER MPPT Solar Smart Digital Controller
- RUNNER MPPT Solar Smart Digital Controller
- GALAXY high power series MPPT solar controller
- MARS outdoor series MPPT solar controller
- eSMART series MPPT solar controller
- MASTER series MPPT solar controller
- Accessories
- (out of product)WISER series MPPT solar controller
- (out of production)Inverter SP Series 350W-20000W
- (Has been removed)
- (out of production)I-Panda SPC Series Inverter
- Certifications
-
- Subscribe
-
Get email updates on new products
- Hot Products
- Contact Us
-
Tel: + 86-755-23091101&+86-755-23091100
Fax: + 86-755-23091102
Information: info@ipandee.com
address: Floor 2, building A2, LiLang Software Park, No. 31, Bulan Road, Nanwan street, Longgang District, Shenzhen
China Post code: 518000 Contact Now
- Follow us
- News
-
-
Why is the inverter starting voltage higher than the minimum voltage?
In the photovoltaic grid-connected inverter, one parameter is strange, that is, the inverter input starting voltage. This voltage is about 30V higher ... -
How to solve the AC inverter overvoltage problem?
just nowPhotovoltaicOn-grid power generation is becoming more and more popular, and ordinary people's homes can see PV power plants in real time. Howe... -
The difference between an improved sine wave and a pure sine wave inverter
This article describes the difference between an improved sine wave and a pure sine wave inverter. ModifiedSine Pure Wave: The most common general pur... -
The world's top ten PV inverter companies
The inverter is also called the power regulator. According to the use of the inverter in the photovoltaic power generation system, it can be divided i... -
Why should the inverter stop working when the grid is out of power?
Some people install a photovoltaic system, they will have a mentality of "even if the power grid is cut off, if there is a sun, and their homes can us... -
What is the difference between MPPT function and solar inverter without MPPT function?
The MPPT controller utilizes maximum power point tracking technology to extract the maximum power from the solar array to charge the battery. The maxi... -
Europe's first waste photovoltaic panel recycling plant
Solar panels have a service life of 20 to 30 years. Along with the mass production of the global solar energy manufacturing industry in the past few y... -
Scientists have discovered that sand can make solar cell silicon materials
According to a report by the Kyodo News Agency on November 6th, visiting professors of the University of Tokyo, Sugawara, and others opened a joint st... -
Domestic energy storage market competition pattern
Energy storage as a new market for many battery manufacturers in China andInverterVendors bring the opportunity to expand new affairs and change the p... -
Portugal will achieve 100% renewable energy supply in 2050
Portugal's Minister of Environment and Energy Transformation João Pedro Matos Fernandes revealed that Portugal will achieve its carbon neutrality tar...
-
I-P-SPC Low Frequency Solar Power Inverter with Built-in Solar Charge Controller 500W
- I-P-SPC inverter has high conversion efficiency, low power consumption, super load-carrying ability, large charging current etc. Users can set output priority (AC first or DC first) .
- Function
- Battery charge Ups AVR voltage regulator
- Strong overload ability
- Low frequency Design
- DC first /AC first
- Sleep Function
- Charge Function
- DC to AC Funiction
- UPS Function
- Output wave form:Pure sine wave
- Material:Metal
- Display:LCD and LED
- controller built-in: yes
- modul structure: Yes
I-P-SPC Series LowFrequency Solar Power Inverter with Built-in Solar ChargeController 500W
1)Highquality low frequency pure sine wave inverter(with utility charge
function and UPS function)
2)Built-in PWMsolar power charge controller
Application
1)Off-grid solar power system
2) Utility and solar complementarypower generation system
Features
1) Easy to install. To configure a solarsystem, users just need to connect it with solar panels and batteries.
2)CPU management,Intelligent control,modulardesign
3)LEDs LCD display. LCD can display variousparameters(such as the output voltage, frequency, working mode)
4)Multifunction design, AVR UPS function.Users don’t need to buy solar, controller, AC charger or stabilizer.
5) Externalbattery connection, it’s convenient for users to expand use time and back-uppower time
6)With super load-carrying ability and highload capacity, this series of inverterscan not only drive resistance load; but also various kinds of inductive loads suchas motor, air conditioner, electric drills, fluorescent lamp, gas lamp. It candrive almost any kinds of load
7)Low frequency pure sine wave circuitdesign, stable quality, easy to maintenance, low failure rate and long servicelife (under proper operation, it can last at least 5 years)
8) Perfect protection: low voltageprotection, high voltage protection, over temperature protection, short-circuitprotection, overload protection
9) CE / EMC / LVD/ RoHS /FCC approvals
10) 2 years warranty, life-long technical support
Function
Off-grid solar power system
1. When connected withbattery and AC loads,users can set it to normal working mode or sleep mode.
1.1 Normal working mode:FREQUENCY in the LCD display is set to 01. No matter it’s connected AC loads or not, theinverter always convert DC to AC. It’sready to supply power to the AC loads. In this mode, the LCD will displayoutput voltage as bellow:
1.2 Sleep mode:FREQUNCYin the LCD display is set as 02.If the power of the connected AC loads is lowerthan 5% of the inverter’s rated power, there will be no output from theinverter. Only the chip of inverter is working. The power consumption of theinverter is only 1-6W. The LCD shows the output voltage 0. If the power of theconnected loads is over 5%,then the inverter will automatically convert DC toAC to supply power for the loads within 5s. The LCD shows the output voltage.As shown below:
Kindly note:
1) Only the solar panel charges thebattery
2) Off-grid solar power system. It issuitable for areas that are lack of utility or plentiful solar
Utility andsolar complementary power generation system
2. UPS function When the inverter is connected to battery andutility, users can set it to utility first (AC first) battery standby mode orbattery first (DC first)utility standby mode.
2.1.Utilityfirst (AC first) battery standby mode : FREQUENCY in the LCD display is set to 01.When utility and battery are connected to the inverter, utility will supplypower to the loads prior. When utility is cut off, the battery willautomatically continue to supply power via power inverter.
Stepsare as follows:
Step1: When utility is available, it will drive the loads directly after voltagebeing stabilized and at the same time charge batteries via power inverter .
Step2: When utility is cut off, the inverter will convert DC to AC automatically toensure uninterrupted power supply within 5ms.
Step3: When utility is available again, inverter will automatically transfer toutility supplying power to loads and charge batteries via power inverter at thesame time.
See Workflowas below.
LCDdisplayed as bellow:
Utility supplypower and charge battery Withoututility and battery supply power
Kindly note:
1) There are 2 ways to charge thebattery, utility and solar panel
2) This system is suitable for powersystems built in areas that are lack of utility. Or people can use solar andutility at the same time.
2.2. Batteryfirst (DC first)utility standy mode: FREQUENCY in the LCD display is set as 03. When utility andbattery are connected to the inverter, battery will supply power to the loadsprior to utility. When battery capacity is not enough, utility will continue tosupply power automatically.
Steps are as follows:
Step1: When battery is available, it will drive the AC loads via power inverter.
Step2: When battery does not have enough power, it will automatically transfer toutility supplying power to the loads
Step3: After the battery is fully charged (e.g. by solar or wind chargecontroller), it will automatically transfer to battery supplying power to theloads via power inverter.
See Workflowas below.
LCD displayed as bellow:
Battery available to supply power Batteryunavailable,utility supply power
Kindly note:
1) There is only one wayto charge the battery: solar panel
2) Thissystem is suitable for areas where electricity is expensive or environmentalareas where solar power can be fully used to save utility bill.such as homesolar&wind system,streetlight solar&wind system
Parameter
Mode |
700VA |
||
Rated Output Capacity |
500W |
||
Peak Power |
1000W |
||
Battery Voltage(DC) |
12V or 24V |
||
PWM Solar Controller |
Voltage |
12V or 24V |
|
Current |
20A |
||
PV Max Input Voltage |
12V System:25V |
||
24V System:50V |
|||
Size W×D×H(mm) |
335*165*375 |
||
Packing Size W×D×H(mm) |
355*185*395 |
||
Net Weight (kg) |
8 |
||
Gross Weight (kg) |
9 |
||
General Parameter |
|||
Working Mode (Setting) |
1 |
Utility first (AC first) battery standby mode |
|
2 |
Sleep Mode,no utility,load’s power is over 5% of rated output power, Inverter start to work automatically |
||
3 |
Battery first (DC first)utility standby mode |
||
AC Input |
Voltage |
220V±35% or 110V+35%(Optional) |
|
Frequency |
50Hz±3% or 60Hz±3% (Optional) |
||
AC Output |
Voltage |
220V±3% or 230V±3 or240V±3% or 100V±3% or 110V±3% (Optional) |
|
Frequency |
50Hz±0.5 or 60Hz±0.5 (Optional) |
||
Utility charge |
AC Charge Current |
0~15A |
|
Charge Time |
Depend on battery capacity and quantity |
||
Battery Protection |
Automatic detection, Charge and discharge protection,Intelligent Management |
||
PV Charge |
Total Current of PV Input Should Be Less Than Rated Current of PWM solar controller |
||
Display |
Display Mode |
LCD+LED |
|
Display Information |
Input voltage,output voltage,output frequency,battery capacity,Load condition,Status Information |
||
Output Wave Type |
Pure sine wave output,Total Harmonic Distortion THD≤3 |
||
Overload Ability |
>120% 1 min,>130% 10s |
||
Power Consumption |
Sleep Mode |
1~6W |
|
Normal Mode |
1~3A |
||
Conversion Efficiency |
80%~90% |
||
Transfer Time |
<5ms (AC to DC / DC to AC) |
||
Protection |
Overload output,short-circuit,high-voltage input,low-voltage input,overheat |
||
Environment |
Temperature |
-10℃~50℃ |
|
Humidity |
10%~90% |
||
Altitude |
≤4000m |
Theabove is our standard parameter. Subject to change without prior notice.
Wehave our own professional inverter and controller R&D team and we provide technical support and OEM ODM service
Thecontroller information above is our company’s standard parameter.It can bechanged to other PWM solar charge controller.ConnectionDiagram
Others
Please see the outline of the design,technicaldocuments,user manuals,product brochures, etc.Research and developmentdepartment made 1st editionon May 5, 2014Tel:+86-15002089033
Contact Person:Henry Feng
PDF Show:PDF