Browse Categories
EMMPT48 series MPPT solar charge controller
The Explorer-NS series MPPT solar charge controlle
MPPT solar charge controller eSmart4
EXPLORER-M MPPT Solar Smart Digital Controller
EXPLORER MPPT Solar Smart Digital Controller
RUNNER MPPT Solar Smart Digital Controller
GALAXY high power series MPPT solar controller
MARS outdoor series MPPT solar controller
eSMART series MPPT solar controller
MASTER series MPPT solar controller
Accessories
(out of product)WISER series MPPT solar controller
(out of production)Inverter SP Series 350W-20000W
(Has been removed)
(out of production)I-Panda SPC Series Inverter
Certifications
Contact Us
Tel: + 86-755-23091101&+86-755-23091100  
Fax: + 86-755-23091102   
Information: info@ipandee.com
address: Floor 2, building A2, LiLang Software Park, No. 31, Bulan Road, Nanwan street, Longgang District, Shenzhen   
China Post code: 518000
Contact Now
Follow us
News
Your position: Home > Category > (out of production)I-Panda SPC Series Inverter > I-P-SPC Low Frequency Solar Power Inverter with Built-in Solar Charge Controller 4000W
I-P-SPC Low Frequency Solar Power Inverter with Built-in Solar Charge Controller 4000W

I-P-SPC Low Frequency Solar Power Inverter with Built-in Solar Charge Controller 4000W

  • I-P-SPC inverter has high conversion efficiency, low power consumption, super load-carrying ability, large charging current etc. Users can set output priority (AC first or DC first) .
  • Function
  • Battery charge Ups  AVR voltage regulator
  • Strong overload ability
  • Low frequency Design
  • DC first /AC first
  • Sleep Function
  • Charge Function
  • DC to AC Funiction
  • UPS Function
  • Output wave form:Pure sine wave
  • Material:Metal
  • Display:LCD and LED
  • controller built-in: yes
  • modul structure: Yes

I-P-SPC Series LowFrequency Solar Power Inverter with Built-in SolarCharge Controller 4000W


 

Component

1)Highquality low frequency pure sine wave inverter(with utility charge functionand UPS function)

2)Built-in PWMsolar power charge controller

 

Application

1)Off-grid solar power system

2) Utility and solar complementarypower generation system

Features

1) Easy toinstall. To configure a solar system, users just need to connect it with solarpanels and batteries.

2)CPUmanagement,Intelligent control,modular design

3)LEDsLCD display. LCD can display various parameters(such as the output voltage, frequency,working mode)

4)Multifunctiondesign, AVR UPS function. Users don’t need to buy solar, controller, AC chargeror stabilizer.

5) External battery connection, it’sconvenient for users to expand use time and back-up power time

6)Withsuper load-carrying ability and high load capacity, this series of  inverters can not only drive resistance load;but also various kinds of inductive loads such as motor, air conditioner,electric drills, fluorescent lamp, gas lamp. It can drive almost any kinds ofload

7)Lowfrequency pure sine wave circuit design, stable quality, easy to maintenance, lowfailure rate and long service life (underproper operation, it can last atleast 5 years)

8) Perfectprotection: low voltage protection, high voltage protection, over temperature protection,short-circuit protection, overload protection

9)CE / EMC / LVD/ RoHS /FCC approvals

10)2 years warranty, life-long technicalsupport

 

Function

Off-grid solarpower system

1.   When connected withbattery and AC loads,users can set it to normal working mode or sleep mode. 

 

1.1 Normal workingmode:FREQUENCY in the LCD display is set to01. No matter it’s connected AC loads or not, theinverter always convert DC to AC. 

It’sready to supply power to the AC loads. In this mode, the LCD will displayoutput voltage as bellow:

 

1.2  Sleep mode:FREQUNCYin the LCD display is set as 02.If the power of the connected AC loads is lowerthan 5% of the inverter’s rated power, there will be no output from theinverter. Only the chip of inverter is working. The power consumption of theinverter is only 1-6W. The LCD shows the output voltage 0. If the power of theconnected loads is over 5%,then the inverter will automatically convert DC toAC to supply power for the loads within 5s. The LCD shows the output voltage.As shown below:

 

Kindly note:

1) Only the solar panel charges thebattery

2) Off-grid solar power system. Itis suitable for areas that are lack of utility or plentiful solar

 

Utility andsolar complementary power generation system


2. UPSfunction  When the inverter is connectedto battery and utility, users can set it to utility first (AC first) batterystandby mode or battery first (DC first)utility standby mode.

2.1.Utilityfirst (AC first) battery standby mode : FREQUENCY in the LCD display is set to 01.When utility and battery are connected to the inverter, utility will supplypower to the loads prior. When utility is cut off, the battery willautomatically continue to supply power via power inverter.

   Stepsare as follows:

   Step1: When utility is available, it will drive the loads directly after voltagebeing stabilized and at the same time charge batteries via power inverter .

   Step2: When utility is cut off, the inverter will convert DC to AC automatically toensure uninterrupted power supply within 5ms.

   Step3: When utility is available again, inverter will automatically transfer toutility supplying power to loads and charge batteries via power inverter at thesame time.

See Workflowas below.


LCDdisplayed as bellow:

  

Kindly note:

1) There are 2 ways to charge thebattery, utility and solar panel

2) This system is suitable for powersystems built in areas that are lack of utility. Or people can use solar andutility at the same time.

2.2. Batteryfirst (DC first)utility standy mode: FREQUENCY in the LCD display is set as 03. When utility andbattery are connected to the inverter, battery will supply power to the loadsprior to utility. When battery capacity is not enough, utility will continue tosupply power automatically.

Steps are as follows:

Step1: When battery is available, it will drive the AC loads via power inverter.

Step2: When battery does not have enough power, it will automatically transfer toutility supplying power to the loads

Step3: After the battery is fully charged (e.g. by solar or wind chargecontroller), it will automatically transfer to battery supplying power to theloads via power inverter.

See Workflowas below.

 

LCDdisplayed as bellow:

 

Kindlynote:

1) There is only one way to charge thebattery: solar panel

2) This system is suitable for areas whereelectricity is expensive or environmental areas where solar power can be fullyused to save utility bill.such as home solar&wind system,streetlightsolar&wind system

 

Parameter

           Mode                                    

6000VA

Rated Output Capacity

4000W

Peak Power

8000W

Battery Voltage(DC)

 48V

PWM Solar Controller

Voltage

48V

Current

60A

PV Max Input Voltage

 48V System:100V

Size W×D×H(mm)

420*260*605

Packing Size W×D×H(mm)

440*280*625

Net Weight (kg)

50

Gross Weight (kg)

55

General Parameter

Working Mode (Setting)

1

Utility first (AC first) battery standby mode

2

Sleep Mode,no utility,load’s power is over 5% of rated output power, Inverter start to work automatically

3

Battery first (DC first)utility standby mode

AC Input

Voltage

220V±35% or 110V+35%(Optional)

Frequency

50Hz±3% or 60Hz±3% (Optional)

AC Output

Voltage

220V±3% or 230V±3 or240V±3% or 100V±3% or 110V±3% (Optional)

Frequency

50Hz±0.5 or 60Hz±0.5 (Optional)

Utility charge

AC Charge Current

0~15A

Charge Time

Depend on battery capacity and quantity

Battery Protection

Automatic detection, Charge and discharge protection,Intelligent Management

PV Charge

Total Current of PV Input Should Be Less Than Rated Current of PWM solar controller

Display

Display Mode

LCD+LED

Display Information

Input voltage,output voltage,output frequency,battery capacity,Load condition,Status Information

Output Wave Type

Pure sine wave output,Total Harmonic Distortion THD≤3

Overload Ability

>120% 1 min,>130% 10s

Power Consumption

Sleep Mode

1~6W

Normal Mode

1~3A

Conversion Efficiency

80%~90%

Transfer Time

<5ms (AC to DC / DC to AC)

Protection

Overload output,short-circuit,high-voltage input,low-voltage input,overheat

Environment

Temperature

-10℃~50℃

Humidity

10%~90%

Altitude

≤4000m

Theabove is our standard parameter. Subject to change without prior notice.

Wehave our own professional inverter and controller R&D team and we provide technical support and OEM ODMservice

Thecontroller information above is our company’s standard parameter.It can bechanged to other PWM solar charge controller.

 

ConnectionDiagram


Others

Please see the outline ofthe design,technical documents,user manuals,product brochures, etc.Research anddevelopment department made  1stedition on May 5, 2014.
Shenzhen ipandee New Energy Technology & Science Co., Ltd

Tel:+86-15002089033

Contact Person:Henry Feng

PDF Show:PDF

Send Inquiry
captcha
https://kefu5.cckefucloud.com/vclient/chat/?websiteid=p9rjd9g58z6e70x5e6vpx31vpm2kwyb4&wc=39157e7a&clerkid=906266