I-P-SPC Low Frequency Solar Power Inverter with Built-in Solar Charge Controller 1500WI-P-SPC Low Frequency Solar Power Inverter with Built-in Solar Charge Controller 1500W

I-P-SPC Low Frequency Solar Power Inverter with Built-in Solar Charge Controller 1500W

  • I-P-SPC inverter has high conversion efficiency, low power consumption, super load-carrying ability, large charging current etc. Users can set output priority (AC first or DC first) .
  • Function
  • Battery charge Ups  AVR voltage regulator
  • Strong overload ability
  • Low frequency Design
  • DC first /AC first
  • Sleep Function
  • Charge Function
  • DC to AC Funiction
  • UPS Function
  • Output wave form:Pure sine wave
  • Material:Metal
  • Display:LCD and LED
  • controller built-in: yes
  • modul structure: Yes

I-P-SPC Series Low Frequency Solar Power Inverter with Built-in Solar Charge Controller 1500W


Component

1)High quality low frequency pure sine wave inverter(with utility charge function and UPS function)

2)Built-in PWM solar power charge controller

 

Application

1)Off-grid solar power system

2) Utility and solar complementary power generation system

Features

1) Easy to install. To configure a solar system, users just need to connect it with solar panels and batteries.

2)CPU management,Intelligent control,modular design

3)LEDs LCD display. LCD can display various parameters(such as the output voltage, frequency, working mode)

4)Multifunction design, AVR UPS function. Users don’t need to buy solar, controller, AC charger or stabilizer.

5) External battery connection, it’s convenient for users to expand use time and back-up power time

6)With super load-carrying ability and high load capacity, this series of  inverters can not only drive resistance load; but also various kinds of inductive loads such as motor, air conditioner, electric drills, fluorescent lamp, gas lamp. It can drive almost any kinds of load

7)Low frequency pure sine wave circuit design, stable quality, easy to maintenance, low failure rate and long service life (under proper operation, it can last at least 5 years)

8) Perfect protection: low voltage protection, high voltage protection, over temperature protection, short-circuit protection, overload protection

9) CE / EMC / LVD/ RoHS /FCC approvals

10) 2 years warranty, life-long technical support

 

Function

Off-grid solar power system

1.    When connected with battery and AC loads,users can set it to normal working mode or sleep mode. 

 

1.1 Normal working mode:FREQUENCY in the LCD display is set to 01. No matter it’s connected AC loads or not, the inverter always convert DC to AC.  It’s ready to supply power to the AC loads. In this mode, the LCD will display output voltage as bellow:

 

1.2  Sleep mode:FREQUNCY in the LCD display is set as 02.If the power of the connected AC loads is lower than 5% of the inverter’s rated power, there will be no output from the inverter. Only the chip of inverter is working. The power consumption of the inverter is only 1-6W. The LCD shows the output voltage 0. If the power of the connected loads is over 5%,then the inverter will automatically convert DC to AC to supply power for the loads within 5s. The LCD shows the output voltage. As shown below:

 

Kindly note:

1) Only the solar panel charges the battery

2) Off-grid solar power system. It is suitable for areas that are lack of utility or plentiful solar

 

Utility and solar complementary power generation system

 

2. UPS function  When the inverter is connected to battery and utility, users can set it to utility first (AC first) battery standby mode or battery first (DC first)utility standby mode.

2.1.Utility first (AC first) battery standby mode : FREQUENCY in the LCD display is set to 01. When utility and battery are connected to the inverter, utility will supply power to the loads prior. When utility is cut off, the battery will automatically continue to supply power via power inverter.

   Steps are as follows:

   Step 1: When utility is available, it will drive the loads directly after voltage being stabilized and at the same time charge batteries via power inverter .

   Step 2: When utility is cut off, the inverter will convert DC to AC automatically to ensure uninterrupted power supply within 5ms.

   Step 3: When utility is available again, inverter will automatically transfer to utility supplying power to loads and charge batteries via power inverter at the same time.

See Workflow as below.

 

LCD displayed as bellow:

  

Kindly note:

1) There are 2 ways to charge the battery, utility and solar panel

2) This system is suitable for power systems built in areas that are lack of utility. Or people can use solar and utility at the same time.

2.2. Battery first (DC first)utility standy mode: FREQUENCY in the LCD display is set as 03. When utility and battery are connected to the inverter, battery will supply power to the loads prior to utility. When battery capacity is not enough, utility will continue to supply power automatically.

Steps are as follows:

Step 1: When battery is available, it will drive the AC loads via power inverter.

Step 2: When battery does not have enough power, it will automatically transfer to utility supplying power to the loads

Step 3: After the battery is fully charged (e.g. by solar or wind charge controller), it will automatically transfer to battery supplying power to the loads via power inverter.

See Workflow as below.

 

LCD displayed as bellow:


Kindly note:

1) There is only one way to charge the battery: solar panel

2) This system is suitable for areas where electricity is expensive or environmental areas where solar power can be fully used to save utility bill.such as home solar&wind system,streetlight solar&wind system

 

Parameter

           Mode                                    

2000VA

Rated Output Capacity

1500W

Peak Power

3000W

Battery Voltage(DC)

24V or 48V

PWM Solar Controller

Voltage

24V or 48V

Current

30A

PV Max Input Voltage

24V System:50V

 48V System:100V

Size W×D×H(mm)

350*220*460

Packing Size W×D×H(mm)

370*240*480

Net Weight (kg)

20

Gross Weight (kg)

22

General Parameter

Working Mode (Setting)

1

Utility first (AC first) battery standby mode

2

Sleep Mode,no utility,load’s power is over 5% of rated output power, Inverter start to work automatically

3

Battery first (DC first)utility standby mode

AC Input

Voltage

220V±35% or 110V+35%(Optional)

Frequency

50Hz±3% or 60Hz±3% (Optional)

AC Output

Voltage

220V±3% or 230V±3 or240V±3% or 100V±3% or 110V±3% (Optional)

Frequency

50Hz±0.5 or 60Hz±0.5 (Optional)

Utility charge

AC Charge Current

0~15A

Charge Time

Depend on battery capacity and quantity

Battery Protection

Automatic detection, Charge and discharge protection,Intelligent Management

PV Charge

Total Current of PV Input Should Be Less Than Rated Current of PWM solar controller

Display

Display Mode

LCD+LED

Display Information

Input voltage,output voltage,output frequency,battery capacity,Load condition,Status Information

Output Wave Type

Pure sine wave output,Total Harmonic Distortion THD≤3

Overload Ability

>120% 1 min,>130% 10s

Power Consumption

Sleep Mode

1~6W

Normal Mode

1~3A

Conversion Efficiency

80%~90%

Transfer Time

<5ms (AC to DC / DC to AC)

Protection

Overload output,short-circuit,high-voltage input,low-voltage input,overheat

Environment

Temperature

-10℃~50℃

Humidity

10%~90%

Altitude

≤4000m


The above is our standard parameter. Subject to change without prior notice.

We have our own professional inverter and controller R&D team and we provide technical support and OEM ODM service

The controller information above is our company’s standard parameter.It can be changed to other PWM solar charge controller.

 

 Connection Diagram


Others

Please see the outline of the design,technical documents,user manuals,product brochures, etc.Research and development department made  1st edition on May 5, 2014..