Browse Categories
EMMPT48 series MPPT solar charge controller
The Explorer-NS series MPPT solar charge controlle
MPPT solar charge controller eSmart4
EXPLORER-M MPPT Solar Smart Digital Controller
EXPLORER MPPT Solar Smart Digital Controller
RUNNER MPPT Solar Smart Digital Controller
GALAXY high power series MPPT solar controller
MARS outdoor series MPPT solar controller
eSMART series MPPT solar controller
MASTER series MPPT solar controller
Accessories
(out of product)WISER series MPPT solar controller
(out of production)Inverter SP Series 350W-20000W
(Has been removed)
(out of production)I-Panda SPC Series Inverter
Certifications
Contact Us
Tel: + 86-755-23091101&+86-755-23091100  
Fax: + 86-755-23091102   
Information: info@ipandee.com
address: Floor 2, building A2, LiLang Software Park, No. 31, Bulan Road, Nanwan street, Longgang District, Shenzhen   
China Post code: 518000
Contact Now
Follow us
News
Your position: Home > Category > (out of production)I-Panda SPC Series Inverter > I-P-SPC China factory DC AC Power Controller 350W~20000W
I-P-SPC China factory DC AC Power Controller 350W~20000WI-P-SPC China factory DC AC Power Controller 350W~20000WI-P-SPC China factory DC AC Power Controller 350W~20000W

I-P-SPC China factory DC AC Power Controller 350W~20000W

  • Strong overload ability
  • Low frequency Design
  • DC first /AC first
  • Sleep Function
  • Charge Function
  • DC to AC Funiction
  • UPS Function
  • Output wave form:Pure sine wave
  • Material:Metal
  • Display:LCD and LED
  • controller built-in: yes
  • modul structure: Yes

Features

1) Easy to install. Toconfigure a solar system, users just need to connect it with solar panels andbatteries.

2)CPU management,Intelligentcontrol,modular design

3)LEDs LCD display. LCDcan display various parameters(such as the output voltage, frequency, workingmode)

4)Multifunction design,AVR UPS function. Users don’t need to buy solar, controller, AC charger or stabilizer.

5)External battery connection, it’s convenient for users to expand use time andback-up power time

6)With superload-carrying ability and high load capacity, this series of  inverters can not only drive resistance load;but also various kinds of inductive loads such as motor, air conditioner,electric drills, fluorescent lamp, gas lamp. It can drive almost any kinds ofload

7)Low frequency puresine wave circuit design, stable quality, easy to maintenance, low failure rateand long service life (under proper operation,it can last at least 5 years)

8) Perfect protection: lowvoltage protection, high voltage protection, over temperature protection, short-circuitprotection, overload protection

9) CE / EMC / LVD/ RoHS/FCC approvals

10) 2 years warranty, life-long technical support


 

Function

1.   Sole inversion function under inversion mode(only connected to battery),can be set to normal working mode and sleep mode



1.1  Normal working mode:FREQUENCY in the LCD display is set as 01. No matter whether there are AC loads connected to the inverter or not, the inverter’s output terminal will always have voltage ready to supply power to the loads. Under this mode, the LCD will be displayed as bellow:

                       


1.2 Sleep mode:FREQUNCY in the LCD display is set as 02.If thepower of the connected AC loads is lower than 5% of the inverter’s rated power,there will be no output from the inverter. Only the chip of inverter is working.The power consumption of the inverter is only 1-6W. The LCD shows the outputvoltage 0. If the power of the connected loads is over 5%,then the inverterwill automatically convert DC to AC to supply power for the loads within 5s.The LCD shows the output voltage. As shown below:





System introduction under this mode:

1) Only the solar panel charges the battery

2) Independent sole off-grid solar power system; suitable for areas that are      lack of utility or have rich solar energy




2. UPS function  When the inverter is connected to battery andutility, users can set it to utility first (AC first) battery standby mode orbattery first (DC first)utility standby mode.

2.1.Utilityfirst (AC first) battery standby mode : FREQUENCY in the LCD display is set to 01.When utility and battery are connected to the inverter, utility will supplypower to the loads prior. When utility is cut off, the battery willautomatically continue to supply power via power inverter.

   Steps are as follows:

   Step 1: When utility is available, it will drivethe loads directly after voltage being stabilized and at the same time chargebatteries via power inverter .

   Step 2: When utility is cut off, theinverter will convert DC to AC automatically to ensure uninterrupted powersupply within 5ms.

   Step 3: When utility is available again,inverter will automatically transfer to utility supplying power to loads andcharge batteries via power inverter at the same time.


See Workflow as below:




LCD displayed as bellow:




Kindly note:

1) There are 2 ways to charge thebattery, utility and solar panel

2) This system is suitable for powersystems built in areas that are lack of utility. Or people can use solar andutility at the same time.

2.2. Battery first(DC first)utility standy mode: FREQUENCY in the LCD display is set as 03. When utility andbattery are connected to the inverter, battery will supply power to the loadsprior to utility. When battery capacity is not enough, utility will continue tosupply power automatically.

Steps are as follows:

Step 1: When battery is available, it will drive the AC loadsvia power inverter.

Step 2: When battery does not have enough power, it willautomatically transfer to utility supplying power to the loads

Step 3: After the battery is fully charged (e.g. by solar orwind charge controller), it will automatically transfer to battery supplyingpower to the loads via power inverter.



See Workflow as below:




LCD displayed as bellow:




System introduction under this mode:

1) There is only way to charge the battery: solar panel

2) This system is suitable for areas where electricity is expensive and environmental areas where solar power can be fully used to save utiliypower, such as family solar&wind system and streetlight solar&wind system


Parameter

Model      

Parameter            

500VA

700VA

1000VA

1500VA

2000VA

3000VA

4000VA

Rated Output Power

350W

500W

700W

1000W

1500W

2000W

3000W

Peak Power

700W

1000W

1500W

2000W

3000W

4000W

6000W

Battery Voltage(DC))

12V or 24V

24V

24V or 48V

PWM Solar Controller

Voltage

12V or 24V

24V

24V or 48V

Current

10A

20A

20A

30A

40A

PV Max Input Voltage

12V System:25V
24V System:50V

24V System:50V

24V System:50V
 48V System:100V

Size W×D×H(mm)

335*165*375

350*220*460

Packing Size W×D×H(mm)

355*185*395

370*240*480

Net Weight (kg)

7

8

12

14

20

23

29

Gross Weight (kg)

8

9

13

16

22

25

31

 

             Model                            
Parameter     

5000VA

6000VA

7000VA

10kVA

15kVA

20kVA

30kVA

Rated Output Power

3500W

4000W

5000W

7000W

10000W

15000W

20000W

Peak Power

7000W

8000W

10000W

14000W

20000W

30000W

40000W

Battery Voltage(DC)

48V

96V

192V

PWM Solar Controller

Voltage

48V

96V

192V

Current

50A

60A

50A

50A

PV Max Input Voltage

100V

200V

400V

Size W×D×H(mm)

420*260*605

420*280*625

Packing Size W×D×H(mm)

440*280*625

440*300*645

Net Weight (kg)

31

50

50

55

85

105

125

Gross Weight (kg)

33

55

60

65

95

115

135

General Parameter

Working Mode

(Setting)

 

01

Utility first (AC first) battery standby mode

02

Sleep Mode,no utility,load’s power is over 5% of rated output power, Inverter start to work automatically

03

Battery first (DC first)utility standby mode

AC Input

Voltage

220V±35% or 110V+35%(Optional)

Frequency

50Hz±3% or 60Hz±3% (Optional)

AC Output

Voltage

220V±3% or 230V±3 or240V±3% or 100V±3%
 or 110V±3% (Optional)

Frequency

50Hz±0.5 or 60Hz±0.5 (Optional)

Utility charge

AC Charge Current

0~15A

Charge Time

Depend on battery capacity and quantity

Battery Protection

Automatic detection, Charge and discharge protection,Intelligent Management

PV Charge

Total Current of PV Input Should Be Less Than Rated Current of PWM solar controller

Display

Display Mode

LCD+LED

Display Information

Input voltage,output voltage,output frequency,battery capacity,load condition,status Information

Output Wave Type

Pure sine wave output,Total Harmonic Distortion THD≤3

Overload Ability

>120% 1 min,>130% 10s

Power Consumption

Sleep Mode

1~6W

Normal Mode

1~3A

Conversion Efficiency

80%~90%

Transfer Time

<5ms (AC to DC / DC to AC)

Protection

Overload ,Short-circuit,High input voltage,Low input voltage,Overheat

Environment

Temperature

-10℃~50℃

Humidity

10%~90%

Altitude

≤4000m



  • The above parameters with “or” means that the parameter needs to do factory settings as per customer’s preference.
  • We have our own professional inverter controller and UPS R&D team and we provide technical support and OEM service.
  • The controller information above is our company’s standard parameter can be changed according to customer’s requirement.


Connection Diagram




Others

Please refer to the outline design, technical documents, product brochures, etc.

Made by Engineering Department, May 5, 2014, 1st Edition


Shenzhen ipandee New Energy Technology & Science Co., Ltd

Tel:+86-15002089033

Contact Person:Henry Feng