Browse Categories
EMMPT48 series MPPT solar charge controller
The Explorer-NS series MPPT solar charge controlle
MPPT solar charge controller eSmart4
EXPLORER-M MPPT Solar Smart Digital Controller
EXPLORER MPPT Solar Smart Digital Controller
RUNNER MPPT Solar Smart Digital Controller
GALAXY high power series MPPT solar controller
MARS outdoor series MPPT solar controller
eSMART series MPPT solar controller
MASTER series MPPT solar controller
Accessories
(out of product)WISER series MPPT solar controller
(out of production)Inverter SP Series 350W-20000W
(Has been removed)
(out of production)I-Panda SPC Series Inverter
Certifications
Contact Us
Tel: + 86-755-23091101&+86-755-23091100  
Fax: + 86-755-23091102   
Information: info@ipandee.com
address: Floor 2, building A2, LiLang Software Park, No. 31, Bulan Road, Nanwan street, Longgang District, Shenzhen   
China Post code: 518000
Contact Now
Follow us
News
Your position: Home > Category > (out of production)I-Panda SPC Series Inverter > 20000w I-Panda SPC series controller and inverter hybird
20000w I-Panda SPC series controller and inverter hybird20000w I-Panda SPC series controller and inverter hybird20000w I-Panda SPC series controller and inverter hybird20000w I-Panda SPC series controller and inverter hybird

20000w I-Panda SPC series controller and inverter hybird

  • Component
  • 1)High quality low frequency pure sine wave inverter(with utility charge   
  • function and UPS function)
  • 2)Built-in PWM solar power charge controller
  • Application
  • 1)Off-grid solar power system
  • 2)solar power system with utility power as a complementary
Features
1) Easy to install. To configure a solar system, customers only need to connect it with solar panels and batteries.
2)CPU management and control,modular design
3)LCD display,can visually display various parameters(such as the output voltage, frequency, working mode, etc).
4)Multifunction design,customers don’t need to buy solar, controller, charger and stabilizer,etc.
5) External battery connection, convenient to expand back-up power time; user can connect as many batteries as needed according to the local sunlight and wind.
6)With super load-carrying ability and high load capacity, this series of  inverters can not only drive resistance load; but also various kinds of inductive loads, such as motor, air conditioner, electric drills, fluorescent lamp, gas lamp, etc. It can drive almost any kinds of load.
7)Low frequency pure sine wave circuit design, good system stability, easy for maintenance, low failure rate and long service life (under proper operation, it may be as long as 5 years).
8) Perfect protection: low voltage protection, over voltage protection, overheat protection, short-circuit protection, overloads protection.
9) CE / EMC / LVD/ RoHS /CCC approvals.
10) 2 years warranty, life-long technical supports.

Function
1. Sole inversion function under inversion mode(only connected to battery, can be set to normal working mode and sleep
1.1 Normal working mode:FREQUENCY in the LCD display is set as 01. No matter whether there are AC loads connected to the inverter or not, the inverter’s output terminal will always have voltage ready to supply power to the loads. Under this mode, the LCD will be displayed as bellow:

1.2  Sleep mode:FREQUENCY in the LCD display is set as 02. If the power of the loads that connected to the inverter is lower than 5% of the inverter’s rated power, there will be no output from the inverter. That is to say, only the chip of inverter is working under such condition and the power consumption is only 1-6W; If the power of the loads that connected to the inverter is higher than 5% of the inverter’s rated power, then the inverter will automatically start the inversion function and supply power to the loads within 5s. As shown below:
System introduction under this mode:

1) Only the solar panel charges the battery
2) Independent sole off-grid solar power system; suitable for areas that are      lack of utility or have rich solar energy
2. UPS function under utility mode(connected to battery and utility) .Can be set as utility first, battery standby mode and battery first, utility standby mode.
2.1. Utility first, battery standby UPS mode: FREQUENCY in the LCD display is set as 01. When both utility and battery are connected to the inverter, utility will supply power to the loads prior to the battery. When utility is cut off, the battery will automatically continue to supply power after inversion.
  
Steps are as follows:
Step 1: When utility power is available, it will output directly after voltage being stabilized and charge batteries at the same time.
Step 2: When utility power is cut off suddenly, the inverter will convert DC power to AC power automatically to ensure uninterrupted power supply within 5ms.
Step 3: When utility power becomes available again, it will automatically transfer to utility supplying power to loads and charge batteries at the same time.

See Workflow as below.
LCD displayed as bellow:
System introduction under this mode:
1) There are 2 ways to charge the battery, utility and solar panel
2) This system is suitable for power systems built in areas lacking utility or power systems that frequently used in areas with/without utility
2.2. Battery first, utility standby UPS mode: FREQUENCY in the LCD display is set as 03.  When both utility and battery are connected to the inverter,

battery will supply power to the loads prior to utility. When battery capacity is not enough, utility will continue to supply power automatically.
Steps are as follows:
Step 1: When battery has enough power, it will supply power to the loads directly
Step 2: When battery does not have enough power, it will automatically transfer to utility supplying power to the loads
Step 3: After the battery is fully charged (e.g. by solar or wind charge controller), it will then automatically transfer to battery supplying power to the loads.

See Workflow as below.
LCD displayed as bellow:
System introduction under this mode:
1) There is only way to charge the battery: solar panel
2) This system is suitable for areas where electricity is expensive and e
nvironmental areas where solar power can be fully used to save utiliypower, such as family solar&wind system and streetlight solar&wind system


Parameter

           Mode                                   

30KVA

Rated Output Capacity

20KW

Peak Power

40KW

Battery Voltage(DC)

 192V

PWM Solar Controller

Voltage

 192V

Current

50A

PV Max Input Voltage

400V

Size W×D×H(mm)

420*280*625

Packing Size W×D×H(mm)

440*300*645

Net Weight (kg)

125

Gross Weight (kg)

135

General Parameter

Working Mode (Setting)

1

Utility First, Battery Standby

2

Sleep Mode,no utility,load’s power higher than 5% of rated power, start to work automatically

3

Battery first, utility standby

AC Input

Voltage

220V±35% or 110V+35%(Optional)

Frequency

50Hz±3% or 60Hz±3% (Optional)

AC Output

Voltage

220V±3% or 230V±3 or240V±3% or 100V±3% or 110V±3% (Optional)

Frequency

50Hz±0.5 or 60Hz±0.5 (Optional)

Utility charge

AC Charge Current

0~15A

Charge Time

Depend on battery capacity and quantity

Battery Protection

Automatic detection, Charge and discharge protection,Intelligent Management

PV Charge

Total Current of PV Input Should Be Less Than Rated Current

Display

Display Mode

LCD+LED

Display Information

Input voltage,output voltage,output frequency,battery capacity,Load condition,Status Information

Output Wave Type

Pure sine wave output,waveform distortion rate≤3

Overload Ability

>120% 1 min,>130% 10s

Power Consumption

Sleep Mode

1~6W

Normal Mode

1~3A

Conversion Efficiency

80%~90%

Transfer Time

<5ms (AC to DC / DC to AC)

Protection

Overload output,short-circuit,high-voltage input,low-voltage input,overheat

Environment

Temperature

-10℃~50℃

Humidity

10%~90%

Altitude

≤4000m



The above parameters with “or” means that the parameter needs to do  factory settings as per customer’s preference.
The controller information above is our company’s standard parameter and can be changed according to customer’s requirement.
We have our own professional inverter controller and UPS R&D team and we provide technical support and OEM service.

Connection Diagram
Others
Please refer to the outline design, technical documents, product brochures, etc.
Made by Engineering Department, May 5, 2014, 1st Edition.
Shenzhen ipandee New Energy Technology & Science Co., Ltd

Tel:+86-15002089033

Contact Person:Henry Feng

PDF Show:PDF

Send Inquiry
captcha
https://kefu5.cckefucloud.com/vclient/chat/?websiteid=p9rjd9g58z6e70x5e6vpx31vpm2kwyb4&wc=39157e7a&clerkid=906266