- Bladeren door rubrieken
- EMMPT48 series MPPT solar charge controller
- The Explorer-NS series MPPT solar charge controlle
- MPPT solar charge controller eSmart4
- EXPLORER-M MPPT Solar Smart Digital Controller
- EXPLORER MPPT Solar Smart Digital Controller
- RUNNER MPPT Solar Smart Digital Controller
- GALAXY-serie met hoog vermogen
- Mars buiten-serie
- eSmart serie MPPT zonne-controller
- MASTER-serie MPPT-zonneregelaar
- Accessoires
- (Uit product) WISER serie MPPT zonnecontroller
- (Uit productie) Inverter SP Series 350W-20000W
- (Is verwijderd)
- (Uit productie) I-Panda SPC-serie omvormer
- Certificeringen
-
- Inschrijven
-
Ontvang e-mailupdates over nieuwe productenOntvang e-mailupdates over nieuwe producten
- Neem contact op
-
Tel: + 86-755-23091101 & + 86-755-23091100
Fax: + 86-755-23091102
Informatie: info@ipandee.com
Adres: Vloer 2, Gebouw A2, Lilang Software Park, No. 31, Bulay Road, Nanwan Street, Longgang District, Shenzhen
China Postcode: 518000 Contact nu
- Volg ons
-
-
Waarom is de startspanning van de omvormer hoger dan de minimumspanning?
In de fotovoltaïsche netgekoppelde omvormer is één parameter vreemd, dat wil zeggen de startspanning van de inverteringang. Deze spanning is hoger ... -
Hoe het overspanningsprobleem van de wisselstroomomvormer op te lossen?
nufotovoltaïscheOn-grid stroomopwekking wordt steeds populairder, en gewone mensen thuis kunnen PV-centrales in real time zien. Echter, voor de betro... -
Het verschil tussen een verbeterde sinusgolf en een zuivere sinusomvormer
Dit artikel beschrijft het verschil tussen een verbeterde sinusgolf en een zuivere sinusomvormer. ModifiedSine Pure Wave: de meest algemene omvormers ... -
'S Werelds top tien PV-omvormers
De omvormer wordt ook wel de vermogensregelaar genoemd.Aangezien van het gebruik van de omvormer in het fotovoltaïsche energieopwekkingssysteem, kan ... -
Wat is het verschil tussen MPPT-functie en zonne-omvormer zonder MPPT-functie?
De MPPT-controller maakt gebruik van de maximale technologie voor het volgen van vermogenspunten om het maximale vermogen uit de zonne-energiecollecti... -
Waarom zou de omvormer niet meer werken als het stroomnet uitvalt?
Sommige mensen in de installatie van fotovoltaïsche systemen, zal een soort van hold "stroomstoring, zelfs als er zon is, hun huizen toegang tot elek... -
Europa's eerste afvalafvalbedrijf voor fotovoltaïsche panelen
Zonnepanelen hebben een levensduur van 20 tot 30 jaar. Met een paar jaar geleden na het productieproces massaproductie wereldwijde zonne-energie, een ... -
Wetenschappers hebben ontdekt dat zand zonnecellen van silicium kan maken
Volgens de Japanse Kyodo News meldde op 6 november een visiting professor aan de Universiteit van Tokio karpervijver tonen Chendeng mensen open en de ... -
Binnenlandse energieopslag concurrentiepatroon
Energieopslag als een nieuwe markt voor veel batterijfabrikanten in China eninverterVerkopers bieden de mogelijkheid nieuwe zaken uit te breiden en de... -
Portugal zal in 2050 100% hernieuwbare energievoorziening realiseren
Portugese minister van Milieu en Energie transformatie Jo? OPedroMatos Fernandes is gebleken dat Portugal zal 2050 koolstof neutrale en objectieve, da...
-
Supplier of 30a mppt solar charge controller Smart2 series
- Brand Name: I-Panda
- Model Number: I-P-SMART2-DC12/24/48V-60A
- Rated Voltage: DC12V/24V/48V auto recognition
- Peak effeciency: 99%
- Color: green/blue
- Display: LCD+LED
- 4 Smart key buttons: Yes
- Charge mode: mppt
- Communication port: RS232 and LAN
- Data set and Monitor: Yes
- 3 charge stages: fast charge, constant voltage, floating charge
- Battery type: General type; others be defined by users
This is a solar charge controller 40A ~60A that have automatic max. power point tracking function with high efficiency that almost 30%~60% higher than traditional charge controller. It also features the functions of system voltage auto recognition, wide rang of PV input ,charge for all kinds of battery,automatic discharge control,RS 232 / LAN communication function and so on. It is very high-end product for solar market with its best partner I-P-TPI2 model Inverter/Charger/UPS.
Application
1. Industrial, commercial, household off grid solar energy generation system
2. Movable off grid solar energy generation system
3. Communication base stations
4. New energy education business
5. Solar Monitoring System
6. Solar Street Lighting System
Reasons to choose
1. 30%-60% solar panels saved
1) Peak efficiency 99%, take most from solar panels
2) Charge for all kinds of batteries, 3 charge stage to protect battery.
Reduce consumption, cost saved.
2. Data monitor and set. Parameters from solar panels like charge current/voltage and IP gate address, total generation power, etc can be showed. 4 kinds DC load control, automaticly save ernergy both from human and solar. Sit beside your PC to monitor your power system.
3. Lan commucation and RS232 port.
4. Software to monitor 100pcs equipments at the same time on one screen on a computer.
Features
1. MPPT charge mode,conversion efficiency upto 99%
2. 12V/24V/48V system auto recognize;
3. Wide range of PV input with max. is DC150V .
4. Unlimited parallel connection
5. Journal function , Save function set ,Date ,time ,Generating capacity and so on .
6.Charge mode: three stages (fast charge ,constant charge ,floating charge) .It prolongs service life of the batteries .
7.Discharge mode: ON/OFF mode, double time control mode,PV voltage control mode ,PV voltage+time delay mode and so on .
8.Recommended battery types: sealed lead acid, vented, gel, NiCd battery. Other types of the batteries can also be defined.
9.Most information could be provide by LCD and LED like: model no.,PV input voltage,battery type,battery voltage,charging current,charging power,working status and so on. Also customer's information like company name,website and logo can be added into Solar Eagle software.
10.RS232 and LAN communication port. IP and Gate address could be user define it satisfy global area.And communication protocol can be provided to help customer manage all information .
11.The upper computer software is displayed in 11 languages, it could show work status and set parameters of the discharge system.
12.With intelligent design,the device can be upgraded online lifelong.
13.Adopting the well-known brand components,the devices can suffer the temperature not less than 105°C.The service life is designed to use for 10 years in theory.
14.Compliance with the 2002/95/EC environment protecting demand, doesn't include the Cadmium, hydride and fluoride etc material
15.Equipment integrity: controller + CD-ROM(microcomputer software) + communication wire + temperature sensing wire+Anderson terminals;
16.CE,ROHS certifications approved.
Parameter
Model:I-P-SMART2-40A/50A/60A -series |
40A |
50A |
60A |
|||||
Charge Mode |
Maximum Power Point Tracking |
|||||||
Method |
3 stages: fast charge(MPPT),constant voltage, floating charge |
|||||||
System Type |
DC12V/24V/48V |
Automatic recognition |
||||||
System Voltage |
12V system |
DC9V~DC15V |
||||||
24V system |
DC18V~DC30V |
|||||||
48Vsystem |
DC36V~DC60V |
|||||||
Soft Start Time |
12V/24V/48Vsystem |
≤10S |
||||||
Dynamic Response Recovery Time |
12V/24V/48Vsystem |
500us |
||||||
Conversion Efficiency |
12V/24V/48Vsystem |
≥96.5%,≤99% |
||||||
PV Modules Utilization Rate |
12V/24V/48Vsystem |
≥99% |
||||||
Input Characteristics |
||||||||
MPPT Working Voltage and Range |
12V system |
DC18V~DC150V |
||||||
24V system |
DC34~DC150V |
|||||||
48V system |
DC65~DC150V |
|||||||
Low Voltage Input Protection Point |
12V system |
DC16V |
||||||
24V system |
DC30V |
|||||||
48V system |
DC60V |
|||||||
Low Voltage Input Recovery Point
|
12V system |
DC22V |
||||||
24V system |
DC34V |
|||||||
48V system |
DC65V |
|||||||
Max DC Voltage |
12V/24V/48V system |
DC160V |
||||||
Input Overvoltage Protection Point |
12V/24V/48V system |
DC150 |
||||||
Input Overvoltage Recovery Point |
12V/24V/48V system |
DC145V |
||||||
Max. PV Power |
12V system |
570W |
700W |
900W |
||||
24V system |
1130W |
1400W |
1700W |
|||||
48V system |
2270W |
2800W |
3400W |
|||||
Output Characteristics |
||||||||
Selectable Battery Types (Default type is GEL battery) |
12V/24V/48V system |
Sealed lead acid, vented, Gel, NiCd battery |
||||||
Constant Voltage |
12V/24V/48V system |
Please check the charge voltage according to the battery type form. |
||||||
Floating Charge Voltage |
12V/24V/48V system |
|||||||
Over Charge Protection Voltage |
12V system |
14.6V |
||||||
24V system |
29.2V |
|||||||
48V system |
58.4V |
|||||||
Rated Output Current |
12V/24V/48V system |
40A |
50A |
60A |
||||
Current-limiting Protection |
12V/24V/48V system |
44A |
55A |
66A |
||||
Rate charge current |
12V/24V/48V System |
40A |
50A |
60A |
||||
Temperature Factor |
12V/24V/48V system |
±0.02%/℃ |
||||||
Temperature Compensation |
12V/24V/48V system |
14.2V-(The highest temperature-25℃)*0.3 |
||||||
Output Ripples(peak) |
12V/24V/48V system |
200mV |
||||||
Output Voltage Stability Precision |
12V/24V/48V system |
≤±1.5% |
||||||
Charge voltage Peak-Peak Ripple |
12V/24V/48V System |
200mV |
||||||
Charger voltage accuracy |
12V/24V/48V System |
≤±1.5% |
||||||
Discharge characteristic |
||||||||
Setting Control |
Controller or LAN |
|||||||
Max discharge current |
12V/24V/48V System |
40A |
||||||
Discharge protection |
12V/24V/48V System |
fuse 30A*2 |
||||||
Double-time control |
12V/24V/48V System |
On in morning ,off in morning / On in night ,off in night |
||||||
ON / OFF mode |
12V/24V/48V System |
ON / OFF |
||||||
PV voltage control |
12V/24V/48V System |
PV voltage on,PV voltage off |
||||||
PV voltage / time delay control |
12V/24V/48V System |
PV voltage on,time delay off |
||||||
Discharge voltage protection |
12V/24V/48V System |
Output off when it under setting voltage; Factory set is 10.5 .( Note : set based on 1 battery ) |
||||||
Communication Features |
||||||||
RS232 Communication |
12V/24V/48V System |
Chose COM communication |
||||||
LAN Communication |
12V/24V/48V System |
Set IP and Gate address for controller and solar eagle ;Then chose TCP communication |
||||||
Protection |
||||||||
Input Low Voltage Protection |
Check the input characteristics |
|||||||
Input Overvoltage Protection |
Check the input characteristics |
|||||||
Input Polarity Reversal Protection |
yes |
|||||||
Output Overvoltage Protection |
Check the output characteristics |
|||||||
Output Polarity Reversal Protection |
yes |
|||||||
Short-circuit Protection |
Recover after eliminating the Short-circuit fault, no problem for long term Short-circuit |
|||||||
Temperature Protection |
95℃ |
|||||||
Temperature protection |
Above 85℃,decrease the output power, decrease 3A per degree. |
|||||||
Other Parameters |
||||||||
Noise |
≤40dB |
|||||||
Thermal methods |
Forced air cooling, fan speed rate regulated by temperature, when inner temperature is too low, fan ran slowly or stop; when controller stop working, fan also stop ran. |
|||||||
Components |
World brand raw materials. Compliance with EU standards. All rated temperature of electrolytic capacitors not less than 105℃ |
|||||||
Smell |
No peculiar smell and toxic substances. |
|||||||
Environment Protection |
Meet the 2002/95/EC,no cadmium hydride and fluoride |
|||||||
Physical |
||||||||
Measurement DxWxH (mm) |
270*185*90 |
|||||||
N.G(kg) |
3 |
|||||||
G.N(kg) |
3.6 |
|||||||
Color |
Blue/Green (optional) |
|||||||
Safety |
CE, RoHS, PSE,FCC |
|||||||
EMC |
EN61000 |
|||||||
Type of Mechanical Protection |
IP21 |
|||||||
Environment |
||||||||
Humidity |
0~90%RH ( no condense) |
|||||||
Altitude |
0~3000m |
|||||||
Operating Temperature |
-20℃ ~ +40℃ |
|||||||
Storage Temperature |
-40℃ ~ +75℃ |
|||||||
Atmospheric Pressure |
70~106kPa |
Note: OEM and ODM service are provided. The 36V/72V/96V model also can be custom made for you.
Product Parts
NO. |
Quantity |
Description |
1 |
1 unit |
Charge controller |
2 |
2 pc |
Terminals |
3 |
2 pc |
Gallow pulley (For install the controller on the wall ) |
4 |
4 set |
Screw (For install the controller on the wall ) |
5 |
1 pc |
232 turn to RJ45 communication cable |
6 |
1 pc |
User manual |
7 |
1 pc |
Temperature sensing wire |
8 |
2 pc |
Fuse wire |
Upper Computer Software and Test Software
MPPT Connection
Certificates
CE
FCC
ROHS
Service and Contact
1. OEM and ODM orders are provided.
2. Power solution consult available based on technical group
3. 24 months warranty; 3 to 10 years extended
4. Free technical study and discussion
Tel:+86 15002089033
Contactpersoon:Wenshen Huang
PDF-show:Pdf