- Sfoglia le categorie
- EMMPT48 series MPPT solar charge controller
- The Explorer-NS series MPPT solar charge controlle
- MPPT solar charge controller eSmart4
- EXPLORER-M MPPT Solar Smart Digital Controller
- EXPLORER MPPT Solar Smart Digital Controller
- RUNNER MPPT Solar Smart Digital Controller
- GALAXY serie ad alta potenza
- Marte serie all'aperto
- regolatore solare MPPT serie eSmart
- Regolatore solare serie MPTER MASTER
- Accessori
- (Fuori prodotto) Regolatore solare MPPT
- (Fuori produzione) Inverter serie SP 350W-20000W
- (È stato rimosso)
- (Fuori produzione) Inverter serie I-Panda SPC
- Certificazioni
-
- sottoscrivi
-
Ricevi aggiornamenti via e-mail sui nuovi prodotti
- Contattaci
-
Tel: + 86-755-23091101 & + 86-755-23091100
Fax: + 86-755-23091102
Informazioni: info@ipandee.com.
Indirizzo: Floor 2, Building A2, Lilang Software Park, No. 31, Bullan Road, Nanwan Street, Distretto di Longgang, Shenzhen
CODICE CINALE: 518000 Contatta ora
- Seguici
-
-
Perché la tensione di avviamento dell'inverter è superiore alla tensione minima?
Nell'inverter collegato alla rete fotovoltaica, un parametro è strano, cioè la tensione di avviamento dell'ingresso dell'inverter. Questa tensione ... -
Come risolvere PV inverter AC problema sovratensioni?
orafotovoltaicoLa generazione di energia in rete sta diventando sempre più popolare e le case delle persone comuni possono vedere le centrali fotovol... -
La differenza tra un'onda sinusoidale migliorata e un inverter a onda sinusoidale pura
Questo articolo descrive la differenza tra un'onda sinusoidale migliorata e un inverter a onda sinusoidale pura. Onda pura modificata: Gli inverter pe... -
Le migliori dieci aziende di inverter fotovoltaici del mondo
Il regolatore di potenza dell'inverter noto anche, secondo il sistema inverter PV uso può essere suddivisa in rete di alimentazione indipendente e ut... -
Qual è la differenza tra la funzione MPPT e l'inverter solare senza funzione MPPT?
Il controller MPPT utilizza la tecnologia di tracciamento del punto di massima potenza per estrarre la massima potenza dall'array solare per caricare ... -
Perché l'inverter dovrebbe smettere di funzionare quando la rete è scarica?
Alcune persone nella realizzazione di impianti fotovoltaici, si terrà una sorta di "interruzione di corrente, anche se c'è il sole, le loro case han... -
Il primo impianto di riciclaggio di pannelli fotovoltaici per rifiuti in Europa
I pannelli solari hanno una durata di servizio da 20 a 30 anni. Con un paio di anni fa, dopo che la produzione di massa di produzione solare globale, ... -
Gli scienziati hanno scoperto che la sabbia può produrre materiali di silicio a celle solari
Secondo un rapporto dell'agenzia di stampa Kyodo, il 6 novembre, i visiting professor dell'Università di Tokyo, Sugawara, e altri hanno aperto uno st... -
Modello di concorrenza sul mercato del deposito di energia domestica
Stoccaggio di energia come nuovo mercato per molti produttori di batterie in Cina e in CinaInverterI venditori offrono l'opportunità di espandere nuo... -
Il Portogallo realizzerà il 100% di energia rinnovabile nel 2050
Ministro portoghese dell'Ambiente e dell'Energia trasformazione Jo? OPedroMatos Fernandes ha rivelato che il Portogallo 2050 è carbon neutral e ogget...
-
I-Panda PC software MPPT solar charge controller Smart 2 series 40A~60A
- Brand Name: I-Panda
- Model Number: I-P-SMART2-DC12/24/48V-40A 50A 60A
- Rated Voltage: DC12V/24V/48V auto recognition
- Peak effeciency: 99%
- Color: green/blue
- Display: LCD+LED
- 4 Smart key buttons: Yes
- Charge mode: mppt
- Communication port: RS232 and LAN
- Data set and Monitor: Yes
- 3 charge stages: fast charge, constant voltage, floating charge
- Battery type: General type; others be defined by users
Introduction:
This is a solar charge controller 40A ~60A that have automatic max. power point tracking function with high efficiency that almost 30%~60% higher than traditional charge controller. It also features the functions of system voltage auto recognition, wide rang of PV input ,charge for all kinds of battery,automatic discharge control,RS 232 / LAN communication function and so on. It is very high-end product for solar market.
Feature:
1.MPPT charge mode,conversion efficiency upto 99%
2.12V/24V/48V system auto recognize;
3.Wide range of PV input with max. is DC150V .
4.Unlimited parallel connection
5.Journal function , Save function set ,Date ,time ,Generating capacity and so on .
6.Charge mode: three stages (fast charge ,constant charge ,floating charge) .It prolongs service life of the batteries .
7.Discharge mode: ON/OFF mode, double time control mode,PV voltage control mode ,PV voltage+time delay mode and so on .
8.Recommended battery types: sealed lead acid, vented, gel, NiCd battery. Other types of the batteries can also be defined.
9.Most information could be provide by LCD and LED like: model no.,PV input voltage,battery type,battery voltage,charging current,charging power,working status and so on. Also customer's information like company name,website and logo can be added into Solar Eagle software.
10.RS232 and LAN communication port. IP and Gate address could be user define it satisfy global area.And communication protocol can be provided to help customer manage all information .
11.The upper computer software is displayed in 11 languages, it could show work status and set parameters of the discharge system.
12.With intelligent design,the device can be upgraded online lifelong.
13.Adopting the well-known brand components,the devices can suffer the temperature not less than 105℃.The service life is designed to use for 10 years in theory.
14.Compliance with the 2002/95/EC environment protecting demand, doesn't include the Cadmium, hydride and fluoride etc material
15.Equipment integrity: controller + CD-ROM(microcomputer software) + communication wire + temperature sensing wire+Anderson terminals;
16.CE,ROHS certifications approved.
17.2 years warranty. And 3~10 years extended warranty service also can be provided.
Parameter:
Model:I-P-SMART2-40A/50A/60A -series |
40A |
50A |
60A |
|||||
Charge Mode |
Maximum Power Point Tracking |
|||||||
Method |
3 stages: fast charge(MPPT),constant voltage, floating charge |
|||||||
System Type |
DC12V/24V/48V |
Automatic recognition |
||||||
System Voltage |
12V system |
DC9V~DC15V |
||||||
24V system |
DC18V~DC30V |
|||||||
48Vsystem |
DC36V~DC60V |
|||||||
Soft Start Time |
12V/24V/48Vsystem |
≤10S |
||||||
Dynamic Response Recovery Time |
12V/24V/48Vsystem |
500us |
||||||
Conversion Efficiency |
12V/24V/48Vsystem |
≥96.5%,≤99% |
||||||
PV Modules Utilization Rate |
12V/24V/48Vsystem |
≥99% |
||||||
Input Characteristics |
||||||||
MPPT Working Voltage and Range |
12V system |
DC18V~DC150V |
||||||
24V system |
DC34~DC150V |
|||||||
48V system |
DC65~DC150V |
|||||||
Low Voltage Input Protection Point |
12V system |
DC16V |
||||||
24V system |
DC30V |
|||||||
48V system |
DC60V |
|||||||
Low Voltage Input Recovery Point
|
12V system |
DC22V |
||||||
24V system |
DC34V |
|||||||
48V system |
DC65V |
|||||||
Max DC Voltage |
12V/24V/48V system |
DC160V |
||||||
Input Overvoltage Protection Point |
12V/24V/48V system |
DC150 |
||||||
Input Overvoltage Recovery Point |
12V/24V/48V system |
DC145V |
||||||
Max. PV Power |
12V system |
570W |
700W |
900W |
||||
24V system |
1130W |
1400W |
1700W |
|||||
48V system |
2270W |
2800W |
3400W |
|||||
Output Characteristics |
||||||||
Selectable Battery Types (Default type is GEL battery) |
12V/24V/48V system |
Sealed lead acid, vented, Gel, NiCd battery |
||||||
Constant Voltage |
12V/24V/48V system |
Please check the charge voltage according to the battery type form. |
||||||
Floating Charge Voltage |
12V/24V/48V system |
|||||||
Over Charge Protection Voltage |
12V system |
14.6V |
||||||
24V system |
29.2V |
|||||||
48V system |
58.4V |
|||||||
Rated Output Current |
12V/24V/48V system |
40A |
50A |
60A |
||||
Current-limiting Protection |
12V/24V/48V system |
44A |
55A |
66A |
||||
Rate charge current |
12V/24V/48V System |
40A |
50A |
60A |
||||
Temperature Factor |
12V/24V/48V system |
±0.02%/℃ |
||||||
Temperature Compensation |
12V/24V/48V system |
14.2V-(The highest temperature-25℃)*0.3 |
||||||
Output Ripples(peak) |
12V/24V/48V system |
200mV |
||||||
Output Voltage Stability Precision |
12V/24V/48V system |
≤±1.5% |
||||||
Charge voltage Peak-Peak Ripple |
12V/24V/48V System |
200mV |
||||||
Charger voltage accuracy |
12V/24V/48V System |
≤±1.5% |
||||||
Discharge characteristic |
||||||||
Setting Control |
Controller or LAN |
|||||||
Max discharge current |
12V/24V/48V System |
40A |
||||||
Discharge protection |
12V/24V/48V System |
fuse 30A*2 |
||||||
Double-time control |
12V/24V/48V System |
On in morning ,off in morning / On in night ,off in night |
||||||
ON / OFF mode |
12V/24V/48V System |
ON / OFF |
||||||
PV voltage control |
12V/24V/48V System |
PV voltage on,PV voltage off |
||||||
PV voltage / time delay control |
12V/24V/48V System |
PV voltage on,time delay off |
||||||
Discharge voltage protection |
12V/24V/48V System |
Output off when it under setting voltage; Factory set is 10.5 .( Note : set based on 1 battery ) |
||||||
Communication Features |
||||||||
RS232 Communication |
12V/24V/48V System |
Chose COM communication |
||||||
LAN Communication |
12V/24V/48V System |
Set IP and Gate address for controller and solar eagle ;Then chose TCP communication |
||||||
Protection |
||||||||
Input Low Voltage Protection |
Check the input characteristics |
|||||||
Input Overvoltage Protection |
Check the input characteristics |
|||||||
Input Polarity Reversal Protection |
yes |
|||||||
Output Overvoltage Protection |
Check the output characteristics |
|||||||
Output Polarity Reversal Protection |
yes |
|||||||
Short-circuit Protection |
Recover after eliminating the Short-circuit fault, no problem for long term Short-circuit |
|||||||
Temperature Protection |
95℃ |
|||||||
Temperature protection |
Above 85℃,decrease the output power, decrease 3A per degree. |
|||||||
Other Parameters |
||||||||
Noise |
≤40dB |
|||||||
Thermal methods |
Forced air cooling, fan speed rate regulated by temperature, when inner temperature is too low, fan ran slowly or stop; when controller stop working, fan also stop ran. |
|||||||
Components |
World brand raw materials. Compliance with EU standards. All rated temperature of electrolytic capacitors not less than 105℃ |
|||||||
Smell |
No peculiar smell and toxic substances. |
|||||||
Environment Protection |
Meet the 2002/95/EC,no cadmium hydride and fluoride |
|||||||
Physical |
||||||||
Measurement DxWxH (mm) |
270*185*90 |
|||||||
N.G(kg) |
3 |
|||||||
G.N(kg) |
3.6 |
|||||||
Color |
Blue/Green (optional) |
|||||||
Safety |
CE, RoHS, PSE,FCC |
|||||||
EMC |
EN61000 |
|||||||
Type of Mechanical Protection |
IP21 |
|||||||
Environment |
||||||||
Humidity |
0~90%RH ( no condense) |
|||||||
Altitude |
0~3000m |
|||||||
Operating Temperature |
-20℃ ~ +40℃ |
|||||||
Storage Temperature |
-40℃ ~ +75℃ |
|||||||
Atmospheric Pressure |
70~106kPa |
Upper Computer Software and Test Software