- Sfoglia le categorie
- EMMPT48 series MPPT solar charge controller
- The Explorer-NS series MPPT solar charge controlle
- MPPT solar charge controller eSmart4
- EXPLORER-M MPPT Solar Smart Digital Controller
- EXPLORER MPPT Solar Smart Digital Controller
- RUNNER MPPT Solar Smart Digital Controller
- GALAXY serie ad alta potenza
- Marte serie all'aperto
- regolatore solare MPPT serie eSmart
- Regolatore solare serie MPTER MASTER
- Accessori
- (Fuori prodotto) Regolatore solare MPPT
- (Fuori produzione) Inverter serie SP 350W-20000W
- (È stato rimosso)
- (Fuori produzione) Inverter serie I-Panda SPC
- Certificazioni
-
- sottoscrivi
-
Ricevi aggiornamenti via e-mail sui nuovi prodotti
- Contattaci
-
Tel: + 86-755-23091101 & + 86-755-23091100
Fax: + 86-755-23091102
Informazioni: info@ipandee.com.
Indirizzo: Floor 2, Building A2, Lilang Software Park, No. 31, Bullan Road, Nanwan Street, Distretto di Longgang, Shenzhen
CODICE CINALE: 518000 Contatta ora
- Seguici
-
-
Perché la tensione di avviamento dell'inverter è superiore alla tensione minima?
Nell'inverter collegato alla rete fotovoltaica, un parametro è strano, cioè la tensione di avviamento dell'ingresso dell'inverter. Questa tensione ... -
Come risolvere PV inverter AC problema sovratensioni?
orafotovoltaicoLa generazione di energia in rete sta diventando sempre più popolare e le case delle persone comuni possono vedere le centrali fotovol... -
La differenza tra un'onda sinusoidale migliorata e un inverter a onda sinusoidale pura
Questo articolo descrive la differenza tra un'onda sinusoidale migliorata e un inverter a onda sinusoidale pura. Onda pura modificata: Gli inverter pe... -
Le migliori dieci aziende di inverter fotovoltaici del mondo
Il regolatore di potenza dell'inverter noto anche, secondo il sistema inverter PV uso può essere suddivisa in rete di alimentazione indipendente e ut... -
Perché l'inverter dovrebbe smettere di funzionare quando la rete è scarica?
Alcune persone nella realizzazione di impianti fotovoltaici, si terrà una sorta di "interruzione di corrente, anche se c'è il sole, le loro case han... -
Qual è la differenza tra la funzione MPPT e l'inverter solare senza funzione MPPT?
Il controller MPPT utilizza la tecnologia di tracciamento del punto di massima potenza per estrarre la massima potenza dall'array solare per caricare ... -
Il primo impianto di riciclaggio di pannelli fotovoltaici per rifiuti in Europa
I pannelli solari hanno una durata di servizio da 20 a 30 anni. Con un paio di anni fa, dopo che la produzione di massa di produzione solare globale, ... -
Gli scienziati hanno scoperto che la sabbia può produrre materiali di silicio a celle solari
Secondo un rapporto dell'agenzia di stampa Kyodo, il 6 novembre, i visiting professor dell'Università di Tokyo, Sugawara, e altri hanno aperto uno st... -
Modello di concorrenza sul mercato del deposito di energia domestica
Stoccaggio di energia come nuovo mercato per molti produttori di batterie in Cina e in CinaInverterI venditori offrono l'opportunità di espandere nuo... -
Il Portogallo realizzerà il 100% di energia rinnovabile nel 2050
Ministro portoghese dell'Ambiente e dell'Energia trasformazione Jo? OPedroMatos Fernandes ha rivelato che il Portogallo 2050 è carbon neutral e ogget...
-
I-P-SP China factory DC AC Power 3000W
- Application
- 1、Back-up UPS system for industrial, commercial, household,etc
- 2、Removable power and standby power for areas that are lack of utility.
- 3、Off-grid solar or wind power system
- 3.1、Off-grid solar or wind power system
- 3.2、AC first Off-grid solar or wind power system
- 3.3、DC first Off-grid solar or wind power system
Introduction
In DC/AC inversion mode, users can set this series of inverters to normal working mode or sleep mode. In utility mode, it has Auto Voltage Regulation (AVR) function, utility charging function (AC first model) and UPS function. This multifunctional low frequency pure sine wave inverter has the advantages of stable quality, strong load-carrying ability and long service life. It also can work in poor environment. It is the second generation of our low frequency pure sine wave inverter I-P-XD-series.
Features
1、pure sine wave output, full power
2、CPU control,intelligent control,modular design
3、LCD display various parameters
4、Multifunction design (AVR, UPS), extra charger is not needed and electric appliances can be protected.
5、External battery connection, it’s convenient for users to expand use time and back-up power time
6、With super load carrying ability and high load capacity, this series of inverters can not only drive resistance load; but also various kinds of inductive loads, such as motor, air conditioner, electric drills, fluorescent lamp, gas lamp.
7、Low frequency circuit design, stable quality, low failure rate and long service life (under proper operation, it can last at least 5 years)
8、Perfect protection: low voltage protection, high voltage protection, over temperature protection, short-circuit protection, overload protection, alarm alert
9、CE / EMC / LVD/ RoHS Approvals
10、Two years warranty, life-long technical support
Function
1、DC to AC inversion function in inversion mode (only connected with batteries and loads) ,users can set it to normal working mode or sleep mode
1.1、Normal working mode:FREQUNCY in the LCD display is set to 01. No matter it’s connected AC loads or not, the inverter always convert DC to AC. It’s ready to supply power to the AC loads. In this mode, the LCD will display output voltage as bellow:
1.2、Sleep mode:FREQUNCY in the LCD display is set as 02.If the power of the connected AC loads is lower than 5% of the inverter’s rated power, there will be no output from the inverter. Only the chip of inverter is working. The power consumption of the inverter is only 1-6W. The LCD shows the output voltage 0. If the power of the connected loads is over 5%,then the inverter will automatically convert DC to AC to supply power for the loads within 5s. The LCD shows the output voltage. As shown below:
Load’s power<5% of inverter’s rated power Load’s power>5% of inverter’s rated power
2、UPS function When the inverter is connected to battery and utility, users can set it to utility first (AC first) battery standby mode or battery first (DC first)utility standy mode.
2.1、Utility first (AC first) battery standby mode : FREQUENCY in the LCD display is set to 01. When utility and battery are connected to the inverter, utility will supply power to the loads prior. When utility is cut off, the battery will automatically continue to supply power via power inverter.
Steps are as follows:
Step 1: When utility is available, it will drive the loads directly after voltage being stabilized and at the same time charge batteries via power inverter .
Step 2: When utility is cut off, the inverter will convert DC to AC automatically to ensure uninterrupted power supply within 5ms.
Step 3: When utility is available again, inverter will automatically transfer to utility supplying power to loads and charge batteries via power inverter at the same time.
See Workflow as below.
LCD displayed as bellow:
Utility supply power and charge battery Utility is unavailable, battery supply power
2.2、Battery first (DC first)utility standby UPS mode: FREQUENCY in the LCD display is set as 03. When utility and battery are connected to the inverter, battery will supply power to the loads prior to utility. When battery capacity is not enough, utility will continue to supply power automatically.
Steps are as follows:
Step 1: When battery is available, it will drive the AC loads via power inverter.
Step 2: When battery does not have enough power, it will automatically transfer to utility supplying power to the loads
Step 3: After the battery is fully charged (e.g. by solar or wind charge controller), it will automatically transfer to battery supplying power to the loads via power inverter.
See Workflow as below
LCD displayed as bellow:
Battery is available Battery is not available,utility supply power
Parameter:
Model Parameter |
4000VA |
|
Rated Output Capacity |
3000W |
|
Peak Power |
6000W |
|
Battery Voltage(DC) |
24V/48V/96V(optional) |
|
Size W×D×H(mm) |
350*220*460 |
|
Packing Size W×D×H(mm) |
370*240*480 |
|
Net Weight (kg) |
29 |
|
Gross Weight (kg) |
31 |
|
General Parameter |
||
Working Mode |
1 |
Utility first (AC first) battery standby mode |
(Setting) |
2 |
Sleep Mode,no utility,load’s power higher than 5% of inverter rated output power,it will start to work automatically |
|
3 |
Battery first (DC first)utility standby UPS mode |
AC Input |
Voltage |
220V±35% or 110V+35%(optional) |
Frequency |
50Hz±3% or 60Hz±3% (optional) |
|
AC Output |
Voltage |
220V±3% or 230V±3 or 240V±3% or 100V±3% or 110V±3% (optional) |
Frequency |
50Hz±0.5 or 60Hz±0.5 (optional) |
|
Battery charge |
AC Charge Current |
0~15A |
Charge Time |
Depend on battery capacity and quantity |
|
Battery Protection |
Automatic detection, Charge and discharge protection,Intelligent Management |
|
Display |
Display Mode |
LCD |
Display Information |
Input voltage,output voltage,output frequency,battery capacity,Load condition,Status Information |
|
Output Wave Type |
Pure sine wave output,Total Harmonic Distortion THD≤3 |
|
Overload Ability |
>120% 1 min,>130% 10s |
|
Power Consumption |
Sleep Mode |
1~6W |
Normal Mode |
1~3A |
|
Conversion Efficiency |
80%~90% |
|
Transfer Time |
<5ms (AC to DC / DC to AC) |
|
Protection |
Overload ,Short-circuit,High input voltage,Low input voltage,Overheat |
|
Environment |
Temperature |
-10℃~50℃ |
Humidity |
10%~90% |
|
Altitude |
≤4000m |