- Parcourir les catégories
- EMMPT48 series MPPT solar charge controller
- The Explorer-NS series MPPT solar charge controlle
- MPPT solar charge controller eSmart4
- EXPLORER-M MPPT Solar Smart Digital Controller
- EXPLORER MPPT Solar Smart Digital Controller
- RUNNER MPPT Solar Smart Digital Controller
- Série GALAXY haute puissance
- Série extérieure de Mars
- Régulateur solaire MPPT série eSMART
- Régulateur solaire MPPT série MASTER
- Accessoires
- (Hors produit) Régulateur solaire MPPT série WISER
- (Hors production) Onduleur Série SP 350W-20000W
- (A été retiré)
- (Hors production) Onduleur série I-Panda SPC
- Certifications
-
- S\'abonner
-
Recevez des mises à jour par e-mail sur les nouveaux produits
- Nous contacter
-
Tel: + 86-755-23091101 & + 86-755-23091100
Fax: + 86-755-23091102
Information: info@ipandee.com
Adresse: Plancher 2, Bâtiment A2, Lilang Software Park, N ° 31, Bulan Road, Nanwan Street, District de Longgang, Shenzhen
Code postal de Chine: 518000 Contacter maintenant
- Suivez nous
-
-
Pourquoi la tension de démarrage de l'onduleur est-elle supérieure à la tension minimale?
Dans l'onduleur connecté au réseau photovoltaïque, un paramètre est étrange, à savoir la tension de démarrage d'entrée de l'onduleur. Cette te... -
Comment résoudre le problème de surtension de l'onduleur AC?
MaintenantPhotovoltaïqueLa production d'électricité sur réseau devient de plus en plus populaire et les maisons des particuliers peuvent voir les ... -
La différence entre une onde sinusoïdale améliorée et un onduleur à onde sinusoïdale pure
Cet article décrit la différence entre une onde sinusoïdale améliorée et un inverseur à onde sinusoïdale pure. ModifiedSine Pure Wave: Les ondu... -
Les dix plus grandes entreprises d'onduleurs photovoltaïques au monde
L'onduleur est également appelé régulateur de puissance et, selon son utilisation dans le système de production d'énergie photovoltaïque, il peu... -
Pourquoi l'onduleur devrait-il cesser de fonctionner lorsque le réseau est à court d'énergie
Certaines personnes installent un système photovoltaïque, elles ont l’esprit «même si le réseau électrique est coupé, s’il ya du soleil et qu... -
Quelle est la différence entre la fonction MPPT et l’onduleur solaire sans fonction MPPT?
Le contrôleur MPPT utilise la technologie de suivi du point de puissance maximale pour extraire le maximum de puissance du panneau solaire afin de ch... -
Première usine de recyclage de panneaux photovoltaïques en Europe
Les panneaux solaires ont une durée de vie de 20 à 30 ans. Parallèlement à la production de masse de l’industrie mondiale de fabrication d’éner... -
Les scientifiques ont découvert que le sable peut fabriquer des matériaux en silicium pour cellules
Selon un rapport de l'agence de presse Kyodo du 6 novembre, des professeurs invités de l'Université de Tokyo, Sugawara, et d'autres ont ouvert une ... -
Modèle de concurrence sur le marché du stockage d'énergie domestique
Le stockage de l'énergie, nouveau marché pour de nombreux fabricants de batteries en Chine etOnduleurLes vendeurs apportent l’opportunité de déve... -
Le Portugal atteindra 100% d'énergie renouvelable en 2050
Le ministre portugais de l'Environnement et de la Transformation de l'énergie, João Pedro Matos Fernandes, a révélé que le Portugal atteindrait s...
-
I-Panda high quality HPC home use converter built in MPPT solar controller 3000w 40A
- Place of Origin:Shenzhen China (Mainland)
- Brand Name: I-Panda
- Model Number: I-P-HPC-3000W
- Type: DC/AC Inverters
- Technology: CPU control
- Output Power: 3000w
- Output Type: Pure Sine Wave form
- DC Input Voltage: 24v/48V
- AC Input Voltage: 100/110/220/230/240V
- Output Voltage: 100/110/220/230/240V
Introduction
Pure sine wave inverter with built-in MPPT controller I-P-HPC-Series is a module design. It has the advantages of high conversion efficiency, low power consumption and strong load-carrying ability. With intelligent control, users can set charging mode, (Utility as complementary power) AC first mode or DC first mode, timing inversion mode and timing utility mode, on/off mode. It is one of advanced hybrid inverter & controller in the world.
Application
1.Off-grid solar power system
2.Solar and utility complementary power system
Feature
1.Easy to install.To configure a solar system, users just need to connect it with solar panels and batteries
2.CPU management, intelligent control, modular design, LCD display
3.Built-in MPPT controller, high charging efficiency
4.Low power consumption, high conversion efficiency
5.Intellectual,multi-function, it’s convenient for users to make full use of solar energy in different situation
6. External battery connection, it’s convenient for users to expand back-up power time
7.Strong load-carrying ability, low failure rate, easy to maintenance and long service life (under proper operation, it can last at least 5 years)
8.Perfect protection:low voltage protection, high voltage protection, over temperature protection, short-circuit protection, overload protection
9.CE / EMC / LVD/ RoHS Approvals
10.Two years warranty, life-long technical support
Function
1.Charging function
There are 2 modes as shown bellow:
1.1 PV only mode: when PV and utility are both connected to the inverter, only the PV will charge the battery while utility will not charge the battery.
1.2 PV+AC hybrid mode: when PV and utility are both connected to the inverter, both PV and utility will charge the battery.
2.Utility as complementary power UPS function
There are 2 kinds of complementary modes, shown as bellow:
2.1 AC first, DC standby UPS mode
When utility and battery are connected to the inverter, utility will supply power to the loads preferentially. When utility is cut off, the battery will automatically continue to supply power to the loads.
Steps are as follows:
Step 1: When utility power is available, it will drive the loads directly after voltage being stabilized and charge batteries at the same time.
Step 2: When utility power is cut off suddenly, the inverter will convert DC to AC automatically to ensure uninterrupted power supply within 5ms.
Step 3: When utility power is available again, it will automatically transfer to utility supplying power to loads and charge batteries at the same time.
See Workflow as below:
3.Timing function
There are 2 kinds of timing mode:
3.1 On/Off mode: Users can set specific time to turn on/off the output of the inverter.
3.2 Working mode: Battery or utility switchable mode. Users can set specific time when to use battery or utility supplying power (suitable for areas where electric fee is charged differently in different period)
4.Recording/checking function
4.1 Inverter fault checking: Users can check the inverter fault information
4.2 Discharge time checking: Users can check the discharge time of the battery
The “optional” parameter can be set as per customer’s requirement
The above is our standard parameter. Subject to change without prior notice.
We have our own professional inverter and controller R&D team and we provide technical support and OEM ODM service
Parameter
Parameter Model |
1000W |
1500W |
2000W |
3000W |
4000W |
5000W |
|||||||||||
Rated Output Power |
1000W |
1500W |
2000W |
3000W |
4000W |
5000W |
|||||||||||
Peak Power |
2000W |
3000W |
4000W |
6000W |
8000W |
10000W |
|||||||||||
Battery (Lead-acid battery) |
24V |
24V/48V(optional) |
48V |
||||||||||||||
Charging Parameter |
|||||||||||||||||
Charge Mode(setting) |
PV charge |
||||||||||||||||
PV charge + utility charge |
|||||||||||||||||
MPPT Solar Controller |
Voltage |
24V |
24V/48V |
48V |
|||||||||||||
Current |
20A |
25A |
30A |
40A |
40A |
40A |
|||||||||||
Max PV Input Voltage |
100V |
||||||||||||||||
PV Charge Efficiency |
95%~99% |
||||||||||||||||
Max PV Input Power |
568W |
24V: 710W |
24V: 852W |
24V:1136W |
2272W |
2272W |
|||||||||||
48V1420W |
48V: 1704W |
48V: 2272W |
|||||||||||||||
Utility |
AC Charge Current |
0~15A |
|||||||||||||||
Charge Mode |
3-Stage Charging |
||||||||||||||||
Inversion parameter |
|||||||||||||||||
AC Output |
Voltage |
220V±3% or 230V±3 or 240V±3% or 100V±3% |
|||||||||||||||
Frequency |
50Hz±0.5 or 60Hz±0.5 (optional) |
||||||||||||||||
Output wave type |
Pure sine wave output, Total Harmonic Distortion THD≤3 |
||||||||||||||||
Overload ability |
>120% 1 min, >130% 10s |
||||||||||||||||
Power Consumption (under normal working mode) |
0.4A |
24V: 0.5A |
24V: 0.7A |
24V: 0.7A |
0.6A |
0.65A |
|||||||||||
48V: 0.4A |
48V: 0.45A |
48V: 0.5A |
|||||||||||||||
Power Consumption (under sleep mode) |
1-6W |
||||||||||||||||
Inverter Conversion Efficiency |
85%~92% |
||||||||||||||||
Utility Mode |
|||||||||||||||||
AC Input |
Voltage |
220V±35% or 110V+35%(optional) |
|||||||||||||||
Frequency |
The same as utility’s frequency |
||||||||||||||||
AC Output |
Voltage |
220V±5% or 110V+5%(optional) |
|||||||||||||||
Frequency |
The same as utility’s frequency |
||||||||||||||||
Overload Ability |
>120% 1 min,>130% 10s |
||||||||||||||||
(AC first or DC first) priority |
|||||||||||||||||
UPS Output(setting) |
AC first, DC standby |
||||||||||||||||
DC first, AC standby |
|||||||||||||||||
Switch Time |
<5ms (AC to DC / DC to AC) |
||||||||||||||||
Power On |
Set by users |
||||||||||||||||
Timed on / off AC output automatically |
|||||||||||||||||
General Parameter |
|||||||||||||||||
Display |
Display Mode |
LCD+LED |
|||||||||||||||
Display Information |
Input voltage, output voltage, output frequency, battery capacity, load condition, status Information |
||||||||||||||||
Protection |
Overload, short-circuit, high-voltage input, low-voltage input, overheat |
||||||||||||||||
Environment
|
Temperature |
-10℃~50℃ |
|||||||||||||||
humidity |
10%~90% |
||||||||||||||||
Altitude |
≤4000m |
||||||||||||||||
Size W×D×H(mm) |
438*208*413 |
450*246*468 |
|||||||||||||||
Packing Size W×D×H(mm) |
520*310*460 |
540*300*518 |
|||||||||||||||
Net Weight (kg) |
15 |
17 |
19 |
25 |
34 |
35 |
|||||||||||
Gross Weight (kg) |
16 |
18 |
20 |
27 |
40 |
41 |
Tél:+86-15002089033
Personne de contact:Zoe