- Examinar las categorías
- EMMPT48 series MPPT solar charge controller
- The Explorer-NS series MPPT solar charge controlle
- MPPT solar charge controller eSmart4
- EXPLORER-M MPPT Solar Smart Digital Controller
- EXPLORER MPPT Solar Smart Digital Controller
- RUNNER MPPT Solar Smart Digital Controller
- GALAXY serie de alta potencia
- Serie al aire libre de marte
- Controlador solar eSMART serie MPPT
- Controlador solar MASTER serie MPPT
- Accesorios
- (Fuera de producto) Controlador solar MPPT
- (Fuera de producción) Inversor Serie SP
- (Ha sido removido)
- (Fuera de producción) Inversor
- Certificaciones
-
- Suscribir
-
Reciba actualizaciones por correo electrónico sobre nuevos productos
- Contáctenos
-
Tel: + 86-755-23091101 & + 86-755-23091100
Fax: + 86-755-23091102
Información: info@ipandee.com
Dirección: Piso 2, Edificio A2, Parque de software Lilang, No. 31, carretera Bulan, Calle Nanwan, Distrito de Longgang, Shenzhen
Código postal de China: 518000 Contacta ahora
- Síganos
-
-
¿Por qué el voltaje de arranque del inversor es más alto que el voltaje mínimo?
En el inversor conectado a la red fotovoltaica, un parámetro es extraño, es decir, el voltaje de inicio de entrada del inversor. Este voltaje es apr... -
¿Cómo resolver el problema de sobretensión del inversor de CA?
AhoraFotovoltaicaLa generación de energía en la red se está volviendo cada vez más popular, y los hogares de la gente común pueden ver las planta... -
La diferencia entre una onda sinusoidal mejorada y un inversor de onda sinusoidal pura
Este artículo describe la diferencia entre una onda sinusoidal mejorada y un inversor de onda sinusoidal pura. ModifiedSine Pure Wave: los inversores... -
Las diez empresas de inversores fotovoltaicos más importantes del mundo.
El inversor también se denomina regulador de potencia. Según el uso del inversor en el sistema de generación de energía fotovoltaica, se puede div... -
¿Cuál es la diferencia entre la función MPPT y el inversor solar sin la función MPPT?
El controlador MPPT utiliza la tecnología de seguimiento del punto de máxima potencia para extraer la máxima potencia de la matriz solar para carga... -
¿Por qué debería dejar de funcionar el inversor cuando la red no tiene energía?
Algunas personas instalan un sistema fotovoltaico, tendrán una mentalidad de "incluso si se corta la red eléctrica, si hay sol, y sus hogares pueden... -
La primera planta de reciclaje de paneles fotovoltaicos de residuos en Europa.
Los paneles solares tienen una vida útil de 20 a 30 años. ¡Junto con la producción en masa de la industria global de fabricación de energía sola... -
Los científicos han descubierto que la arena puede producir materiales de silicio de células solares
Según un informe de la Agencia de Noticias Kyodo el 6 de noviembre, los profesores visitantes de la Universidad de Tokio, Sugawara y otros, abrieron ... -
Patrón de competencia del mercado de almacenamiento de energía doméstica
El almacenamiento de energía como un nuevo mercado para muchos fabricantes de baterías en China yInversorLos proveedores brindan la oportunidad de e... -
Portugal alcanzará el 100% del suministro de energía renovable en 2050.
El Ministro de Medio Ambiente y Transformación de Energía de Portugal, João Pedro Matos Fernandes, reveló que Portugal alcanzará su objetivo de n...
-
iPanda CC al inversor de onda sinusoidal pura inversor de alimentación de CA con una función de controlador de carga solar MPPT
- potencia de salida relacionada: 1000W, 1500W, 2000W, 3000W, 4000W, 5000W.
- de potencia máxima: doble
- tensión de la batería: 12V / 24V / 48V (opcional)
- tensión de salida: 220 ± 3% o 230 ± 3 o 240V ± 3% o 100 V ± 3% o 110 V ± 3% (opcional)
- integrado controlador de carga solar MPPT
- Tensión: DC 12V / 24V / 48V trabajo auto;
- Corriente: 15A, 20A, 25A, 30A, 40A (opcional);
- max.PV voltaje de entrada: 100V;
- Eficiencia de carga PV: hasta el 99%;
- max.PV potencia de entrada: 568W ~ 2272W.
Introduction
This series of product is a module design of inverter and built-in MPPT controller, which has the advantages of high conversion efficiency, low power consumption and strong load-carrying ability. With intelligent control, customers can set charging mode, (Utility as complementary power) AC first mode or DC first mode, timed inversion mode and timed utility mode, timed on/off sleep mode. This is the currently the most advanced inverter & controller hybrid in the world.
Application
1. Off-grid solar power system
2. Solar power system with utility as complementary power
Feature
1. Easy to install. To configure a solar system, customers only need to connect it with solar panels and batteries;
2. CPU management ,intelligent control,modular design, User-friendly LCD display;
3. Built-in MPPT controller, high charging efficiency ( 95%~99%);
4. Low power consumption, high conversion efficiency(85%~92%);
5. Intellectual,multi-function, convenient for customers with different using environment to fully use the solar energy;
6. External battery connection, convenient to expand back-up power time;
7. Strong load-carrying ability, low failure rate, easy maintenance and long service life (under proper operation, it may be as long as 5 years);
8. Perfect protection: low voltage protection, over voltage protection, overheat protection, short-circuit protection, overloads protection;
9. CE / EMC / LVD/ RoHS Approvals;
10. Two years warranty, life-long technical supports.
Function
1. Charging function
1.1 PV charge the battery, utility will not: when PV and utility are both connected to the machine, only the PV will charge the battery when there is sunlight
1.2 Both PV and utility will charge the battery: when PV and utility are both connected to the machine, AC (utility) will charge the battery. In the meanwhile, PV will also charge the battery if there is sunlight.
2. Utility as complementary power function
2.1 AC first , DC standby UPS mode
When both utility and battery are connected to the machine, utility will supply power to the loads prior to the battery. When utility is cut off, the battery will automatically continue to supply power.
2.2 DC first, AC standby UPS mode
When both utility and battery are connected to the inverter, battery will supply power to the loads prior to utility. When battery capacity is not enough, utility will continue to supply power automatically.
3. Timing function
3.1 Timed on/off normal working mode and sleep mode: can set specific time when to open normal output and when to close AC output to enter sleep mode.
3.2 Battery and utility switchable mode: can set specific time when to use battery or utility supply power (suitable for areas where electric fee is charged according to period in different intervals).
4. Recording/checking function
4.1 Machine fault checking: can check the machine fault information.
4.2 Discharge time checking: can check the discharge time of the battery.
Parameter
Parameter Model |
1000W |
1500W |
2000W |
3000W |
4000W |
5000W |
|||||||||||
Rated Output Power |
1000W |
1500W |
2000W |
3000W |
4000W |
5000W |
|||||||||||
Peak Power |
2000W |
3000W |
4000W |
6000W |
8000W |
10000W |
|||||||||||
Battery (Lead-acid battery) |
24V |
24V/48V(optional) |
48V |
||||||||||||||
Charging Parameter |
|||||||||||||||||
Charge Mode(setting) |
PV charge |
||||||||||||||||
PV charge + utility charge |
|||||||||||||||||
MPPT Solar Controller |
Voltage |
24V |
24V/48V |
48V |
|||||||||||||
Current |
20A |
25A |
30A |
40A |
40A |
40A |
|||||||||||
Max PV Input Voltage |
100V |
||||||||||||||||
PV Charge Efficiency |
95%~99% |
||||||||||||||||
Max PV Input Power |
568W |
24V: 710W |
24V: 852W |
24V:1136W |
2272W |
2272W |
|||||||||||
48V1420W |
48V: 1704W |
48V: 2272W |
|||||||||||||||
Utility |
AC Charge Current |
0~15A |
|||||||||||||||
Charge Mode |
3-Stage Charging |
||||||||||||||||
Inversion parameter |
|||||||||||||||||
AC Output |
Voltage |
220V±3% or 230V±3 or 240V±3% or 100V±3% |
|||||||||||||||
Frequency |
50Hz±0.5 or 60Hz±0.5 (optional) |
||||||||||||||||
Output wave type |
Pure sine wave output, waveform distortion rate≤3 |
||||||||||||||||
Overload ability |
>120% 1 min, >130% 10s |
||||||||||||||||
Power Consumption (under normal working mode) |
0.4A |
24V: 0.5A |
24V: 0.7A |
24V: 0.7A |
0.6A |
0.65A |
|||||||||||
48V: 0.4A |
48V: 0.45A |
48V: 0.5A |
|||||||||||||||
Power Consumption (under sleep mode) |
1-6W |
||||||||||||||||
Inverter Conversion Efficiency |
85%~92% |
||||||||||||||||
Utility Mode |
|||||||||||||||||
AC Input |
Voltage |
220V±35% or 110V+35%(optional) |
|||||||||||||||
Frequency |
The same as utility |
||||||||||||||||
AC Output |
Voltage |
220V±5% or 110V+5%(optional) |
|||||||||||||||
Frequency |
The same as utility |
||||||||||||||||
Overload Ability |
>120% 1 min,>130% 10s |
||||||||||||||||
(AC first or DC first) priority |
|||||||||||||||||
UPS Output(setting) |
AC first, DC standby |
||||||||||||||||
DC first, AC standby |
|||||||||||||||||
Switch Time |
<5ms (AC to DC / DC to AC) |
||||||||||||||||
Power On |
Set by users |
||||||||||||||||
Timed open / close AC output automatically |
|||||||||||||||||
General Parameter |
|||||||||||||||||
Display |
Display Mode |
LCD+LED |
|||||||||||||||
Display Information |
Input voltage, output voltage, output frequency, battery capacity, Load condition, Status Information |
||||||||||||||||
Protection |
Overload output, short-circuit, high-voltage input, low-voltage input, overheat |
||||||||||||||||
Environment
|
Temperature |
-10℃~50℃ |
|||||||||||||||
humidity |
10%~90% |
||||||||||||||||
Altitude |
≤4000m |
||||||||||||||||
Size W×D×H(mm) |
438*208*413 |
450*246*468 |
|||||||||||||||
Packing Size W×D×H(mm) |
520*310*460 |
540*300*518 |
|||||||||||||||
Net Weight (kg) |
15 |
17 |
19 |
25 |
34 |
35 |
|||||||||||
Gross Weight (kg) |
16 |
18 |
20 |
27 |
40 |
41 |
|||||||||||
Products photo
Company photo
Tel:+86 15002089033
Persona de contacto:wenshen huang
Show pdf:Pdf